-M3 x 0.5 through M2.5 x 0.45 x 6l (Hexagon socket head cap screw) M3 x 0.5 x 12.5l (Hexagon head bolt) M3 x 0.5 (Hexagon nut) (12) (5 + Stroke) 2.75 2-M3 x 0.5 through 25 0.2 4 8-28-23 23 Series CXSJ Dimensions: 10 Standard Piping 4-M3 x 0.5 thread depth 4.5 16 12 + Stroke 3.5 8 7.5 2-M5 x 0.8 thread depth 4 (Piping port) 28.5 8 Stroke 15 56 + Stroke 8 3.5 13 1 44.5 + Stroke M5 x 0.8 x 4l
valve Fittings & Tubing Pressure switch Clean gas filter Flow control equipment Filter, Pressure control equipment Air preparation equipment 16 17+ST 4-M3 x 0.5 thread depth 4.5 3.5 8 7.5 2-M5 x 0.8 thread depth 4 (Piping port) 21 8 Steel ball 34 M3 x 0.5 thread depth 3.5 Vacuum suction port 35 Note) 11-, 22: Vacuum suction port 12-, 21: Relief port 61+ST ST 15 49.5+ST 3.5 8 13 1 M5 x 0.8 x 4L
Auto switch mounting screw (M2.5 x 4L) Accessory Flat head watchmakers screwdriver Other than the applicable auto switches listed in How to Order, the following auto switches are mountable. Normally closed (NC = b contact) solid state auto switches (D-F9G/F9H) are also available. For details, refer to page 1593. With pre-wired connector is also available for solid state auto switches.
RS Q G RS H A RZQ MI W S CEP1 CE1 M2.5 x 4l (Included with the auto switch) CE2 ML2B 40 mm or more C J G5-S 4. Avoid wiring patterns in which bending stress and pulling force are repeatedly applied to the lead wires. 5. Please consult with SMC when using in locations where water or coolant liquid, etc is splashing constantly. 6.
CC Straight bladed watchmakers screwdriver Switch mounting screw (M2.5 X 4l) (Accessory) Note) Use a watchmakers screwdriver with a grip diameter of 5 or 6mm to tighten the auto switch mounting screw. Use a tightening torque of 0.05 to 0.1Nm.
CEP1 CE1 Auto switch CE2 ML2B Flat head watchmakers screwdriver C J G5-S CV MVGQ Switch installation screw (M2.5 x 4l) (Accessory option) CC RB J Note) When adjusting the auto switch mounting screws, use a flat head watchmakers screwdriver. The guideline of the tightening torque is 0.05 to 0.1 Nm. Turn another 90 from the position where tightening is felt by hand.
RS Q G RS H A RZQ MI W S CEP1 CE1 M2.5 x 4l (Included with the auto switch) CE2 ML2B 40 mm or more C J G5-S 4. Avoid wiring patterns in which bending stress and pulling force are repeatedly applied to the lead wires. 5. Please consult with SMC when using in locations where water or coolant liquid, etc is splashing constantly. 6.
C85 Flat head watchmakers screwdriver Switch mounting screw (M2.5 x 4l) Accessory C95 Note) When tightening the auto switch mounting screw, use a watchmakers screw driver with a handle about 5 to 6 mm in diameter. Tighten to a torque of approximately 0.05 to 0.1 Nm (0.51 to 1.02 kgfcm).
-M3 x 0.5 through M2.5 x 0.45 x 6l (Hexagon socket head cap screw) M3 x 0.5 x 12.5l (Hexagon head bolt) M3 x 0.5 (Hexagon nut) (12) (5 + Stroke) 2.75 2-M3 x 0.5 through 25 0.2 4 8-28-23 23 Series CXSJ Dimensions: 10 Standard Piping 4-M3 x 0.5 thread depth 4.5 16 12 + Stroke 3.5 8 7.5 2-M5 x 0.8 thread depth 4 (Piping port) 28.5 8 Stroke 15 56 + Stroke 8 3.5 13 1 44.5 + Stroke M5 x 0.8 x 4l
M2.5 x 4l (Included with auto switch) Note) When tightening an auto switch mounting screw, use a watchmakers screwdriver with a handle of approximately 5 to 6 mm in diameter. Also, tighten with a torque of about 0.05 to 0.1 Nm. As a guide, turn about 90 past the point at which tightening can first be felt.
Slotted set screw (M2.5 x 4l) (Included as accessory) Flat head watchmakers screwdriver Auto switch Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. For detailed specifications, refer to page 8-30-1.
Switch mounting screw (M2.5 x 4l) included Switch spacer Correct Incorrect Note) When tightening the auto switch mounting screw, use a watchmakers screwdriver with a handle about 5 to 6 mm in diameter. Also, tighten with a torque of 0.05 to 0.1 Nm.
CLQ MLGP Flat head watchmakers screwdriver RLQ MLU Switch mounting screw (M2.5 x 4l) (Included as accessory) ML1C D-X 20Data Caution When tightening an auto switch mounting screw, use a watchmakers screwdriver with a handle of approximately 5 to 6 mm in diameter. Also, tightening torque should be about 0.05 to 0.1 Nm.
Flat head watchmakers screwdriver Hexagon wrench key 2 Auto switch mounting bracket BMG1-040 Hexagon socket head cap screw (M2.5 x 8l ) Switch mounting screw (M2.5 x 4l ) (Included as accessory) Auto switch Hexagon wrench key 2.5 Hexagon socket head cap screw (M3 x 16l ) Auto switch 9-11-28 28 Compact Guide Cylinder with Lock Series MLGP Operating Range Auto switch model Bore size (mm) 25
M2.5 x 4l (Included with auto switch) Fig. (2) Auto switch mounting Lead wire cover Fig. (3) Installation of lead wire cover Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. For detailed specifications, refer to page 8-30-1. Normally closed (NC = b contact), solid state switch (D-F9G/F9H/Y7G/Y7H type) are also available.
Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 30mm, Cylinder Rod Motion: Normally Extended, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: None, Auto Switch: Rail Mounting, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 30mm, Cylinder Rod Motion: Normally Extended, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: Light & Surge Suppressor, Auto Switch: Rail Mounting, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 45mm, Cylinder Rod Motion: Normally Retracted, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: None, Auto Switch: Rail Mounting, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 60mm, Cylinder Rod Motion: Normally Retracted, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: None, Auto Switch: Rail Mounting, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 60mm, Cylinder Rod Motion: Normally Retracted, Valve Specifications: 4L [220VAC (230VAC) L Plug Connector], Light & Surge Suppressor: None, Auto Switch: Band Mounting, Number: -