Base Mounted Wiring: 30 (Common Pilot EXH), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 10 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 03 (3/8)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (3/8)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8)
Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 10 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: Rc3/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -
Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 10 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: 3/8, Thread: -, Control Unit: -, Release Valve Rated Voltage: -
Base Mounted Wiring: Individual Pilot EXH, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 10 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 3/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Common Pilot EXH, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 10 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 3/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Type: Line Filter, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 3/8B, Nominal filtration(μm): 10, Differential pressure display: Differential pressure indicator, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 3/8B, Nominal filtration(μm): 10, Differential pressure display: Differential pressure indicator, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)
Base Mounted Wiring: Base Mounted Plug-in for Serial Transmission, Stations: 10 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: 3/8, Thread: -, Control Unit: -, Voltage: -
Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 10 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: 3/8, Thread: -, Control Unit: -, Voltage: -
Series: VP500, Exhaust Type: Common Exhaust, Pilot Type: Internal Pilot, Stations: 10 Stations, Symbol: 1, Port Size: 3/8, Thread Type: -
Max Operating Pressure: 21 MPa, Construction: Element Upward Removal, Threaded, Port Size: 3/8 Threaded, Pressure Indicator: Differential Pressure Indicator, Relief Valve: Relief Valve, Fluid: Water-glycol, Emulsion, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
(guideline) Command 2400bps 19200bps 57600bps EE 145 25 10 EU 105 20 10 AB 105 20 10 MO 245 35 15 MD 115 20 10 OE 130 20 10 Calculation Example) Number of controllers connected: 5 Required transmission commands: EE,EU, AB Communication response time ( 25 + 20 + 20 ) x 5 = 325 ms Response time (guidline) 500 450 400 Response time [ms] EE 350 EU,AB,MD,OE 300 MO 250 200 150 100 50 0 1 2 3 4
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
IDX-OM-W037-D PRODUCT NAME Thermo-dryer MODEL Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 This manual is intended to explain the installation and operation of the product. Only people who understand the basic operation of the product, or have basic knowledge and ability to handle industrial machinery, are allowed to work on the product.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.
Specification for Option L 10 1 Safety instructions . 10 1 10 2 Specification . 10 1 10 3 Maintenance . 10 2 Chapter 11 Specification for Option M 11 1 Safety instructions . 11 1 11 2 Specifications . 11 2 11 3 Cautions for handling the motor type auto drain . 11 2 11 4 Electric circuit . 11 2 Chapter 12 Specification for Option R 12 1 Safety instructions . 12 1 12 2 Specifications . 12
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.