ON = A (A B)/4 A = Max. pressure OFF = B + (A B)/4 B = Min. pressure Perform zero clear operation again after restoring the applied pressure to an atmospheric pressure condition. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Analog Output ISE35 Voltage output Current output A B C Range For vacuum pressure Rated pressure range PSE 0 0.0 to 101.0 kPa 101 kPa 5 20 Analog output [mA] Analog output [V] IS For compound pressure 100.0 to 100.0 kPa 100 kPa 100 kPa For positive pressure ISG 0.100 to 1.000 MPa 0.1 MPa 0 1 MPa ZSM1 1 0.6 4 2.4 B A C B A C Pressure Pressure Functions (Refer to pages 41 and 42 for details
3.2 6.5 7 7 15 1 3H9 ( ) depth 3 +0.025 0 4 NN x M4 x 0.7 thread depth 8 B A 3H9 ( ) depth 3 +0.025 0 HA GA Section AA Section BB (mm) ZZ 74 79 90 108 126 176 M 49 54 65 83 101 151 Z 48.5 53.5 64.5 82.5 100.5 150.5 K 23.5 33.5 43.5 53.5 63.5 88.5 J 19.5 29 39 56 60 96 I 13 8.5 9.5 10.5 24.5 38.5 NN 2 2 3 3 4 5 HA 20 30 20 28 46 56 H 28 30 20 28 23 28 GA 17 12 33 43 43 83 G 9 12 13 15 20 27
Caution When removing a cable with connector, a PCW-04T puller is required. 8
ZFC200, 201 ZFC100, 101 Flow rate ( /min (ANR)) O-ring S14 S10 q Bracket Accessory BP-17S BP-16S O-ring is a set with spare element (I-S-A). A bracket is included with the product. 13-10-8 3 Series ZFC Air Suction Filter In-line Type with One-touch Fittings Dimensions Applicable tubing O.D.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD ASSY, VALVE, VT3/VO3 SOL VALVE 3-PORT, DJ, VT3 BASE PT 1/8 PT, 1.91251 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BASE, VALVE, VT3/VO3 SOL VALVE 3-PORT, DJ, VT3 BASE PT 1/8 PT, 3.32529 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BASE, VALVE, VT3/VO3 SOL VALVE 3-PORT, DJ, VT3 BASE PT 1/8 PT, 3.67437 lb
DIN ADIN 2 40 14 - 4 41 ADDRESS,B RATE LEC 0~99 IF 3 ADDRESS B RATE ADDRESS (X10) (X1) 0 8 0 0 0 0 1 1 9 8 98 9 9 99 1 9 0 0 100 0 1 101 2 5 125 B RATE[] B RATE IF ADDRESS100 F A 9 ADDRESS100126 230.4kbps 8 ADDRESS199 7 2 1 ADDRESS100126 115.2kbps 0 ADDRESS199 1LEC-T1IF 115.2kbps 2 15 - 42 CN2SW Profibus CN2SWONProfibus CN2SWOFF LEC-T1LEC-W2 PC/TB CN2 (LEC) CN2SW Profibus
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VT3 BASE PT 1/8 PT, VALVE, VT3/VO3 SOL VALVE 3-PORT, DJ, VT3 BASE PT 1/8 PT, 5.07246 lb
Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
B A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5 4.5 2.5 1.5 3 2 9 8 4.5 3.5 6.5 5.5 14 13 80 16 14 12 10 9.5 7.5 11.5 9.5 9 7 6 4 6.5 4.5 12.5 10.5 8 6 10 8 17.5 15.5 100 17.5 16.5 13.5 12.5 11 10 13 12 10.5 9.5 7.5 6.5 8 7 14 13 9.5
Consider selecting a ZNC series (body size 20) Bernoulli gripper as a substitute. Click here for details. A type with a mounting plate has been added. For the adsorption transfer of thin cloths, films, printed circuit boards, etc.
33 B A 33 B D-A3 D-G39/K39 D-A3C D-G39C/K39C G 1/2 (Applicable cable O.D. 6.8 to 9.6) Auto switch G 1/2 HW A 49 B (Applicable cable O.D. 6.8 to 9.6) Hs 49 Hs 34 56 S M C A U T O S W I T C H S M C A U T O S W I T C H A 36 B 36 Auto switch D-F5/J5 D-F5NTL D-F5W/J59W D-F5BA/F59F D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL Hs Auto switch Hs Auto switch Hs Ht 24.5 SMC SMC Ht A 30 (33) B 14 A 33 B
switch model D-A44 D-A44C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5/A6 D-F5W D-J59W D-F5BAL D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W D-A3/A3C D-A44/A44C D-G39/ G39C D-K39/K39C D-B5/B6 Bore size (mm) Bore size (mm) A B A B A B A B A B A B A B Hs Hs Hs Ht Hs Hs Ht Hs Hw Hs Hw 31 40 40 40 81 9.5 2 10.5 0 72.5 31 4 8.5 2 69 0 0.5 11.5 1.5 38 73 69 38.5 0 0 80.5 3.5 35 43.5
+ A = 100 y, z + A 100 10 y, z + A = 200 y, z + A = 200 y, z + A = 300 y, z + A = 300 1 1 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 700 800 Stroke [mm] Stroke [mm] [Graph 6] Allowable load mass by stroke 32 [Graph 5] Allowable load mass by stroke 25 100 100 y, z + A = 0 y, z + A = 0 y, z + A = 50 y, z + A = 50 10 Load mass [kg] Load mass [kg] 10 y, z + A = 100 y, z + A = 100
0 o @0 i A A MX MTS MY CY !4 !3 y e !2 q r t o !6 @0 !4 !1 q !6 i t y e !5 r u !
Amount of displacement on A when the load is applied at F. Amount of displacement on A when the load is applied at F.
Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.