Description Lead wire color Note 1 L+ Brown 18 to 30 VDC 1: Brown 4: Black 2 DO White Switch output 2 M12 3 L Blue 0 V 4 C/Q Black Communication data (IO-Link)/ Switch output 1 (SIO) 11 2: White 3: Blue ISE7m/7mG Series Function Details Display examples of the main and sub (set value) screens of each mode.
Standard Products IDFAE Series Air flow capacity (m3/h [ANR]) Outlet air pressure dew point Rated inlet condition Page Model Refrigerant Port size 3C 7C 10C IDFA3E 12 15 17 Rc 3/8 IDFA4E 24 31 34 Rc 1/2 IDFA6E 36 46 50 P. 92 to 94 R134a (HFC) IDFA8E 65 83 91 Rc 3/4 IDFA11E 80 101 112 35C 0.7 MPa IDFA15E1 120 152 168 Rc 1 IDFA22E 182 231 254 R 1 IDFA37E R 11/2 273 347 382 P. 95 to 97 R407C
Value x 0.01 (mA or V) 0 Value (-32767.. 32767 ) Lower limit AD value of Analog Range. 10 Lower Limit Value*1 True Output will be fault value. 11 Fault Mode Analog False Output will be held last state. Set output per channel when communication error is occurred.
OUT1 [CoL][] ON OFF ON OFF [F 1] OUT1 -38No.PF-OMO0004CN-E [F 2] OUT2 OUT2 (31 )(32 ) OUT2()[---] <>OUT2 [F 2] [F 2][oU2] [oU2][] [2ot][] 40 41 42 43 -39No.PF-OMO0004CN-E a.
[%F.S.] 2 1 0 OUT OUT OUT OUT 0 D 2D 3D 4D 5D IN IN IN IN 0 1 2 3 4 5 5 (5D) [] [] LFE13/8 inch 0.2 MPa LFE23/4 inch LFE31 inch (mm) D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 68 No.LFE*-OMY0008 4.0 3.5 3.0 2.5 [%F.S.]
Nm (mm) 20 1.5 2.0 0.5 25 2.9 2.0 0.5 32 2.9 2.0 0.5 40 4.9 2.0 0.5 50 11.8 5.0 1.0 63 24.5 5.0 1.0 80 24.5 20.0 2.0 100 42.2 20.0 2.0 6 7 8 9 2-4. 1 2) 3 4 5 6 7 11 1 2 3 1.5~2 2 2. 12 2-5. ,AS 2-6. 2-6-1. CG5N 2-6-2. CG5A 11~2 2 31 4 5 6 7 13 2-6-3.
MHCM2-7S D8.3 205.2 2-M2 x 0.4 thread (Mounting thread) 2-M2 x 0.4 depth 4 (Mounting thread) 2.5 2 1.5 When open 20 When closed 7 10 6 4.5 15 11 7.7 1.8 16.5 6 100.05 (23) M3 x 0.5 (Finger closing port) 2-M2 x 0.4 thread (Attachment mounting thread) 4 0 0.03 3 12-8-23
MHCM2-7S D8.3 205.2 2-M2 x 0.4 thread (Mounting thread) 2-M2 x 0.4 depth 4 (Mounting thread) 2.5 2 1.5 When open 20 When closed 7 10 6 4.5 15 11 7.7 1.8 16.5 6 100.05 (23) M3 x 0.5 (Finger closing port) 2-M2 x 0.4 thread (Attachment mounting thread) 4 0 0.03 3 12-8-23
AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Rated flow (l/min (ANR))(1) 200 500 1000 2000 3500 6000 12000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 1, 11/2 11/2, 2 3/4, 1 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow capacity at a pressure of 0.7MPa.
NO.TQ1050188-OM002 PRODUCT NAME Pressure switch for energy-saving control ejector with N.O. type valve MODEL / Series / Product Number ZK2-ZSV#-A-X188 Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Mounting and Installation 17 Installation 17 Easy
SEL PV 11. 2030 SV 12. SEL 13.
No.EX-OMN0027CN-D PROFIBUS DP SI // EX600-SPRA EX600-ED 2 8 9 11 13 13 15 SI 16 16 17 17 18 LED 22 24 25 26 27 29 29 31 32 42 43 52 52 63 GSD 63 63 SIEMENS PLC S7 64 67 69 70 78 -1No.EX-OMN0027CN-D [][][] (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating
Mechanical Valve Series VM Model VM1000 VM100 VM200 Side piping Bottom piping Side piping Bottom piping Dimensions (mm) 11 X 36 X 16 11 X 28 X 25 17 X 44 X 25 17 X 44 X 30 25 X 40 X 52 Basic Roller Lever One Way Roller Lever Straight Plunger Roller Plunger Cross Roller Plunger Toggle Lever Push Button (Mushroom) Push Button (Extended) Push Button (Flush) Twist Selector (2 position) Key Selector
0.39 5.8 28 0.36 7.6 26 0.35 7.0 1.0 3 8 1 2 3 4 VPA3145 3 4 SYA SYJA Port size Effective area (mm2) Valve model Weight (kg) 12(INOUT) 23(OUTEXH) 1(IN), 2(OUT) 3(EXH) VZA 3 4 1 230 280 280 310 310 330 570 650 650 670 650 670 2 2 1.5 VPA3165 11 4 VFA 11 4 11 4 11 2 VFRA VPA3185 2.3 VPA4 SYJA Dimensions VZA 3 x Rc Pilot port 1 8 VTA VGA VPA VPA3 VPA3 2 x Mounting hole Port size Rc (EXH port
/4" x 11/10" 11/4" 31.75 11/10" 27.95 KQB2 O.D. 3.18 1/16" 1.58 0.086" 2.18 KS KX I.D.
:l 3/86 female thread Maintenance l--I space ~ Drain H I I Dimensions with mounting bracket Model Port size A B C D E F G I J 1 K 1 L 1 MI N I 01 P I 01 RI s B AMH850 11 /2 , 2 460.5 42 348 220 57.5 220 10 463.51 180 I 30 I 15 I 24 I 13 1120 1184 1 220 1110 1 18 I 6 6 SeriesAMH Made to Order Specifications ICD With Differential Pressure Gauge (GD40-2-01) I@ With IN-OUT Flange For ease of
Rc(NPT)11/4 40 to 42 Nm Hysteresis H_1 Item Default setting / With the temperature sensor in parenthesis (Displayed alternately) Flow [L/min] Rc(NPT)11/2 48 to 50 Nm [F 3] Response time setting 1 second Temperature upper limit exceeded If the tightening torque is exceeded, the product can be broken. If the correct tightening torque is not applied, the fittings may become loose.
They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. 4 Analogue output (flow rate) Rc(NPT)3/4 28 to 30 Nm Pin number of the connector at the body side Rc(NPT)1 36 to 38 Nm Maintenance Rc(NPT)11/4 40 to 42 Nm Element Description Rc(NPT)11/2 48 to 50 Nm How to reset the product after a power cut or when the
[F80] Setting of power saving mode No setting [display is turned on] Rc(NPT)11/4 40 to 42 Nm Switch ON Switch OFF Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.
External gripping 11 34 42 65 158 254 force D I.D. Internal 17 45 66 104 193 318 Note 1) Gripping force per finger Effective value (N) gripping force O.D. External gripping S 7.1 27 33 45 131 217 force I.D.