Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing

Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 RS H A Manufacture of Intermediate Stroke BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut RZQ Ordering Refer to standard part number and ordering on page 10-10-2.

Note 2) Use standard power cables for 3 m and 10 m lengths.

: Lead wire F, L, M and P kits 1 to 12 stations M Kit: Multiple connector C8 (For 8) C10 (For 10) T kit 1 to 10 stations 4150 S kit (without unit) Solenoid weight is not included.

Lock Specifications Clamp Specifications Locking action Spring locking (Exhaust locking) Without shim With shim Clamp stroke 10 mm 0 0.5 Unlocking pressure 0.2 MPa or more 10 mm to 12 mm Lock starting pressure 1 pc.

Cooling Capacity HRSH100-A-20/40HRSH100-W-20/4014 16 Ambient temperature 32C Facility water temperature 32C 14 12 Cooling capacity [kW] Cooling capacity [kW] 10.5 10 11.5 12 10 Ambient temperature 43C 8 8 Facility water temperature 40C 6 6 Ambient temperature 45C 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH150

Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to

) Ambient temperature 104F (40C) 10 10 8 8 Ambient temperature 113F (45C) Ambient temperature 113F (45C) 6 6 4 4 2 2 0 0 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] Circulating fluid temperature F [C] Circulating fluid temperature F [C] HRS150-W -20/40(50 Hz) HRS150-W -20/40(60 Hz) 20 20 Facility water temperature 90F (32C)

Cooling Capacity HRS100-A-20/40(50 Hz) HRS100-A-20/40(60 Hz) 14 14 12 12 Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 40C Ambient temperature 32C Ambient temperature 40C 8 8 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature

ZQ 05 1U A-K15L B-EA M G -3 3-N (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)(11)(12) (1) (7) 05 0.5 5) 07 0.7 M SI (kPa) 10 1.0 5) (:psi) P 5) (99 10 ) (2) (8) 1U 3M G (2m) (9) (10) (V ) 6) (3) 0 (M5x0.8) 7) K1 N.C. N.C. K 1 3.2 () K2 N.O. N.C. 6) 2 4 () J1 N.C. 3 6 () J2 N.O. 4 3.2 () 1) ()(N.C.)

10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.

2 4 6 8 10 0 1 2 3 4 5 Work load (W) kg Work load (W) kg Work load (W) kg 300 30 150 L2 200 20 M2 100 L2 mm L2 mm L2 mm W 100 10 50 L2 M2 0 10 30 20 0 1 2 3 4 5 0 2 4 6 8 10 Work load (W) kg Work load (W)kg Work load (W) kg 30 300 150 a=500 a=500 a=500 Horizontal/Lateral a=1000 a=1000 a=1000 20 200 100 a=2000 a=2000 L3 mm L3 mm L3 mm a=2000 L3 100 10 50 W M3 a 0 1 2 3 4 5 0 10 30 20 0 2

L/min 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% Temperature characteristics (25C reference) 3% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F .S.

Parameter Definition Item Content Default setting 0: -10..10 V 1: -5..5 V 2: -20..20 mA 3: 0..10 V 5 Analog Range Set the analog input range per channel. Selects the analog input range. 0..10 V 4: 0..5 V 5: 1..5 V 6: 0..20 mA 7: 4..20 mA 0: None None 6 Analog Filter Sets analog input filtering time per channel.

moment 70 MXW25 70 100 50 30 40 N m 50 MXW20 Pitch moment Yaw moment Roll moment 25 30 40 MXW20 Model 20 Moment N m Moment N m Mp/Mep My/Mey Mr 15 MXW16 20 MXW16 12 5 5 3 MXW 8 10 15 7 10 MXW12 MXW12 10 10 6 MXW12 4 5 7 5 4 3 20 20 12 MXW16 MXW8 MXW8 3 2.5 40 40 25 MXW20 2 110 110 65 2 1.5 MXW25 50 100 200 300 500 700 50 100 200 300 500 Piston speed mm/s Piston speed mm/s (Graph3) (Graph2

2 pcs. 10 10 25 to 5 20 15 5 1 pc. 10 10 25 CXTl25 5 15 10 10 2 pcs. 10 15 20 CXTl 32 40 5 15 10 5 1 pc. 10 10 20 (mm) D-F7lW D-J79W D-F9BAL D-F7NT D-F79F Auto switch model D-A7l D-A8l D-A73C D-A80C D-A7lH D-A80H D-F7l D-J79 D-F7lV D-J79C Applicable model D-F7lWV D-A79W D-F7LF Number of mountings 2 pcs. 5 10 15 15 20 20 25 CXTl 32 40 1 pc. 5 5 10 15 15 20 25 3.8-10 Platform Cylinder Series

ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).

ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).

Remove pilot valve mounting screws (M3, 2 pcs.), rotate the pilot valve at 180 and then re-tighten the valve with the screw.

Cooling Capacity HRSH090-A-20HRSH090-A-4012 12 Ambient temperature 32C Ambient temperature 32C 10 10 Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 43C Ambient temperature 43C 6 6 Ambient temperature 45C 4 4 Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH090-W-20/4014