Content Bore size (mm) CHA40-PS 40 50 63 80 100 125 160 CHA40-PS CHA50-PS CHA63-PS CHA80-PS CHA100-PS CHA125-PS CHA160-PS !7 !8 !9 @0 @1 @2 23 Seal kit consists of items !7 through @2 and can be ordered using the seal kit number for each bore size. Cushion seal CHA50-PS Wiper ring NBR CHA63-PS Set of left nos. !7, !8, !
Tie-rod Type Hydraulic Cylinder/Double Acting, Double Rod Series CHAW 40, 50, 63, 80 100, 125, 160 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !6 !7 @0 @1 !8 @2 !
Furthermore, 80 and 100 are tightened with a large tightening torque, so disassembly will be difficult. Contact SMC if disassembly is required. 205
Cylinder with Lock/Double Acting, Double Rod Series CNA2W 40, 50 63, 80 100 Replacement Procedure is P.351 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.
Seal kit includes a grease pack (32 to 50: 10 g, 63 and 80: 20 g, 100: 30g). Order with the following part number when only the grease pack is needed.
Seal kit includes a grease pack (32 to 50: 10 g, 63 and 80: 20 g, 100: 30g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 157
Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 35
Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 15 is a non-replaceable part, so it is not included in the seal kit. 36
Operate in an ambient humidity range between 45% to 80% (no condensation). 18 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
6 @1 @8 End lock type Piston seal NBR Rod seal CBQ2B20-PS CBQ2B25-PS CBQ2B32-PS CBQ2B40-PS CBQ2B50-PS CBQ2B63-PS CBQ2B80-PS NBR 20 25 32 40 50 63 80 100 CBQ2B20-PS CBQ2B25-PS CBQ2B32-PS CBQ2B40-PS CBQ2B50-PS CBQ2B63-PS CBQ2B80-PS CBQ2B100-PS Tube gasket NBR Using 4 pcs. for 80, 100 Set of left nos. !0, !1, !2, !3, !6, @1, @8 and a grease pack.
Compact Cylinder/Standard Type: Double Acting, Double Rod Construction Series CQ2W 12, 16, 20 25, 32, 40 50, 63, 80 100 Replacement Procedure is P.290 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !1 !3 !2 !1 !3 !
4 Pneumatic type (non-lube) Piston seal Rod seal NBR CQ2B12-PS 12 16 20 25 32 40 50 63 80 100 CQ2B12-PS CQ2B16-PS CQ2B20-PS CQ2B25-PS CQ2B32-PS CQ2B40-PS CQ2B50-PS CQ2B63-PS CQ2B80-PS CQ2B100-PS CQ2B16-PS Gasket CQ2B20-PS CQ2B25-PS CQ2B32-PS Set of left nos. !2, !3, !4.
Corrected exhaust flow rate found with the conversion formula: 0 AMV 0 20 40 60 80 100 120 140 160 180 200 Flow capacity [L/min (ANR)] AMP 95 x 0.5 + 0.1 0.5 = 114 L/min (ANR) When the flow capacity is 80 L/min (ANR), the graph lines of SFE5 and SFE7 reach 80 L/min (ANR), thus either of these two models can be selected.
Applicable actuator and operation range (angle) Sensor unit D-Y7K Air gripper (mm or ) Model Bore size (mm) 10 4 12 16 20 25 32 40 50 63 80 100 MHZ2 MHL2 MHS2 (2 finger) MHS3 (3 finger) MHS4 (4 finger) MHC2 MHW2 Parallel gripper 7 8 8.5 7 5 Wide opening 6.8 10.5 11 12.5 8.5 8 Parallel gripper 6.5 7 7.5 8.5 Parallel gripper 6.5 7 7.5 8 Parallel gripper 6.5 7 7.5 8.5 30 to 10 30 to
Body sizes: 80, 100; Max. horizontal workload, kg: 75 (size 80); 240 (size 100); Max. vertical workload, kg: 70 (size 80); 200 (size 100); Max. speed, mm/s: 5,000; Max. acceleration / deceleration, mm/s2: 50,000; Stroke range, mm: 300 to 3000 (see catalog for increments); Positioning repeatability, mm: ±0.08
3/8 SYJA VZA 5 (EA), 3 (EB) port M5 x 0.8 1 (P) port 1/8 5 (R), 3 (R) port 3/8 VTA EXH port type VGA Common EXH Individual EXH Common EXH Common EXH Common EXH Applicable valve model VFA130 VFA520 VFA330 VPA Applicable stations VPA3 2 to 20 stations 2 to 20 stations 2 to 15 stations 2 to 10 stations Manifold base Weight: W[g] Stations: n W = 29n + 21 W = 51n + 35 W = 63n + 64 W = 97n + 80
No 3000G 45-089 Stripper for round cable (2.0) can be used for a 2-wire type cable. 181 Applicable auto switch list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6
H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port
85 90 100 100 100 239 247 296 320 339 345 44 46 48 51 59 63 3 4 1 3 4, 1 1 1 1 4 1 2 , 2 Dimensions: Auto Feed Tank Float switch Contact point capacity: AC: 15 VA, DC: 15 W Contact point construction: 1a, 1b M Width across flats 12 Float switch Lubrication plug Model A 174 174 234 234 B 70 70 108 108 C 16 16 30 30 D 7 7 7 7 E 91 91 121 121 F 182 182 242 242 G 15 15 16 16 H 24 24 40 40 I