100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

Effective area (mm2) Port size Weight (kg) Model Type of actuation 3.3 1 1 1 1 1 1 1 120 280 300 120 280 300 110 VP4150 1 4 1 2 Single 9.5 2 position 3 position VP4170 3.8 VP4250 1 4 1 2 Double 10 VP4270 4.4 VP4350 Closed center 4.4 Exhaust center 1 110 VP4450 3-6-2 3 Large Size 5 Port Solenoid Valve Rubber Seal Series VP450/470 How to Use DIN Terminal Precautions 1.

4 y r t !3 e i o w !0 !5 Lateral load resisting type: MQQL (Built-in ball bushing) !1 !6 !

Speed controller Maximum cylinder speed mm/s Composite effective area mm C group 16.2 to 21.6 VQ2000 (16.2) SY7000 (21.6) SX7000 (21.6) D group 36 to 45 VQ4000 (36.0) VQ4000 (39.6) VFR3000 (41.4) VFS3000 (36.0) E group 64.8 to 67 G group 180 to 300 VFR6000 (191) VFS6000 (180) VP70 (300) F group 102.6 to 120 2 Standard type 1 With One-touch fitting Select solenoid valves, speed control

2 w y r !0 e 1 New PFA Body 2 New PFA Sensor 3 Super PFA Tube 4 PPS Housing A 5 PPS Housing B 6 PPS Housing C 7 POM Bushing 8 PPS Cap 9 FKM Gasket 10 FKM O-ring 11 SUS304 Thread 12 PVC Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !

06 50 44 3/4 Middle 0.85 to 2.36 9 18 IS 60 53 3/4 Short 1.04 to 2.83 11 22 60 55 1 Short 0.56 to 1.67 10 20 ZSM 100 90 1 1/4 Short 0.57 to 1.67 17 34 PF2 160 140 1 1/2 Short 0.63 to 1.95 26 52 140 125 2 Middle 0.34 to 1.06 23 45 IF IF31-10 280 250 2 1/2 Middle 0.41 to 1.29 45 90 Data 250 220 3 Middle 0.26 to 0.81 40 80 550 480 4 Long 0.33 to 1.05 85 170 Long 1,000 870 5 0.37 to 1.24 150 300

T (mm) (mm) Rod end male thread Applicable bore size V W X U R S T Q Part no.

y OUT side IN side OUT side IN side Communication cable (With connector on both sides) t u t r EX260 Series EX600 Series Specifications Description Communication cable (With connector on one side) Field-wireable connector Part no.

Series VVX31/32/33 Construction/Principal Parts Material Port R Port P Port A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Option Material Description No.

6 q e r t !5 w !4 CUJ CU CQS CQM CQ2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !0 u y RQ MU 32 to 50 With auto switch (Built-in magnet) !6 q e r t !5 i o !1 !3 !2 !7 w !4 D-X 20Data !0 u y Description No.

Note 2) Model MGPL (Ball bushing bearing) cannot be used as a stopper. 63 600 500 400 50 300 40 200 32 100 0 10 20 30 40 Transfer speed (m/min) 8-20-6 7 Compact Guide Cylinder Series MGQ Operating Range when Used as Lifter Select the bore size so that the total load mass is bellow the theoretical output (see the table below). l l Bore size (mm) Theoretical output m m 12, 16 40% or below

Therefore, supply pressure regulated by a built-in regulator e passes through the air supply solenoid valve q and is applied to the pilot chamber r. The pressure in the pilot chamber r increases and operates on the upper surface of the diaphragm t. As a result, the air supply valve y linked to the diaphragm t opens, and a portion of the supply pressure becomes output pressure.

Note 1) Lock position F9BWV F9BW F7BWV J79W F9BA F7BA H R Rear lock Front lock Bore size (mm) Foot Note 2) Flange Double clevis F7NT F79F 32 40 50 63 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-L032 CQ-L040 CQ-L050 CQ-L063 Manual release type F7LF Lead wire length symbols 0.5m . Nil (Example) A80C 3m . L (Example) A80CL 5m . Z (Example) A80CZ None .

How to order L E C C G R ii. Dimensions 71 - 8. Reference Information 8.1 LRC Checksum Calculation Procedure (1) How to calculate the LRC checksum The checksum calculation method in Modbus ASCII mode is based on a Longitudinal Redundancy Checking (LRC) method. (i) All data in the transmitted message is added together, excluding the Start Code : and End Code pair CR, LF.

Leakage voltage Caution Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as 3% or less of the rated voltage. 3.

OUT IN BUS COM A COM B COM C COM D F R P B U S O I R DIA BF SOL RUN GATEWAY UNIT EX500 SERIES 18 19 Switch setting Open the station number switch protective cover and set the switches with a sharp-pointed watchmakers screwdriver etc. NOTE 1. Be sure to turn off the power before setting the switches. 2. Be sure to set these switches before use.