Tightening Torque for Operating Port Operating port Torque (Nm) After tightening by hand, tighten additional 1/6 rotation with a tightening tool. M5 Rc, NPT 1/8 0.8 to 1.0 2. Use the pilot ports and sensor (respiration) port as follows.
When the inlet pressure is shut off and released, the check valve w opens and the pressure in the diaphragm chamber q is released to the inlet side (Figure 2). This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e pushes down the diaphragm.
For details, refer to pages 25 to 48. 6. Replace the pad while referring to the figure below. Lock plate Lever on ejector side ZK2 w ZQ Lock plate ZR Lock screw Adapter plate ZB t 2. After the pad has been replaced, lock the lock plate completely before use. (Refer to q shown in the figure below.)
C J G5-S CV Fig. (6) Piping MVGQ Before connecting the pipes, remove any foreign matter.
Drain outlet Evaporation thermometer Drain separator Volume control valve Capillary tube Compressor for refrigeration Pressure switch Condenser Fan motor Circuit for air, refrigerant 6 8 Series IDU E Dimensions IDU3E to 6E B E D A Q Illuminated switch Evaporation thermometer Ventilation air outlet Compressed air inlet F G Port size Compressed air outlet C Ventilation direction Ventilation
AMH550 AMH150 I Air pressure 0.3MPa ",0.06 '" 0.06 a. ::;; Inlet air pressure 0.3MPa r-a. /;57o.7MPa ::;; ~ / // 0.5MPa ~ ./' 0.7MPa
LQ1-6B25 4-12 LQ1-4N12 LQ1-4B12 6-25 LQ1-6N25 LQ1-6B25 LQ1T61-R3 6 6-25 LQ1-6N25 LQ1-6B25 4-10 LQ1-4N10 LQ1-4B10 6-25 LQ1-6N25 LQ1-6B25 LQ1T61-R4 6 6-25 LQ1-6N25 LQ1-6B25 3-08 LQ1-3N08 LQ1-3B08 6-25 LQ1-6N25 LQ1-6B25 LQ1T61-R5 6 6-19 LQ1-6N19 LQ1-6B19 6-25 LQ1-6N25 LQ1-6B25 6-25 LQ1-6N25 LQ1-6B25 LQ1T61-R6 6 4-12 LQ1-4N12 LQ1-4B12 6-25 LQ1-6N25 LQ1-6B25 6-25 LQ1-6N25 LQ1-6B25 LQ1T61-R7 6
Contact protection box OUT() Brown(Red) 12 10 8 15 16 9 12 6 6 20 25 32 40 50 63 80 100 125 140 160 Reed switch 13 CDJ2, CDVJ CDQ2 to 10 12 6 6 6 6 12 12 6 6 6 6 12 13 12 6 6 6 6 12 13 12 12 12 11 10 12 12 13 13 13 CD-P11 CD-P12 OUT( ) Blue(Black) B P CDXW 6 6 6 CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT 6 6 6 6 6 6 11 13 11 11 11 Note) qIn the case operation load is an inductive load. wIn the
04 6 8 10 10 ZZM Stations 04B Effective area of external silencer is 160 mm2.
O e b u t ) h c n i ( . n i M e l o h . a i D . t W ) f g ( . o N t r a P D L Q M 4 / 1 0 0 7 0 L R K 8 6 . 0 ) 2 . 7 1 ( 9 8 . 0 ) 5 . 2 2 ( 1 2 . 0 ) 3 . 5 ( 5 7 . 0 ) 9 1 ( 8 1 . 0 ) 6 . 4 ( 8 8 / 3 0 0 1 1 L R K 9 8 . 0 ) 7 . 2 2 ( 0 1 . 1 ) 8 2 ( 6 2 . 0 ) 6 . 6 ( 1 9 . 0 ) 3 2 ( 8 2 . 0 ) 7 ( 6 1 2 / 1 0 0 3 1 L R K 4 0 . 1 ) 5 . 6 2 ( 2 2 . 1 ) 1 3 ( 1 3 . 0 ) 8 . 7 ( 4 9 . 0 ) 4
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: None, Lead Wire Length: 6 (600mm)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: None, Lead Wire Length: 6 (600mm)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: None, Lead Wire Length: 6 (600mm)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: None, Lead Wire Length: 6 (600mm)
Symbol: 15R3 (2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Standard w/Power Saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1U (1/4-28UNF, PVDF), Lead Wire Length: 6 (600mm)
Symbol: 15R3 (2 Port, N.C., Port 1 IN, Port 2 OUT), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1U (1/4-28UNF, PVDF), Lead Wire Length: 6 (600mm)
Symbol: 155R (3 Port, Universal), Function: HY (High-pressure w/Power Saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1U (1/4-28UNF, PVDF), Lead Wire Length: 6 (600mm)
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: None, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: None, Lead Wire Length: 600mm, CE Compliant: -