(Option) Foot bracket and manifold mounting possible. 5 to 60C (No freezing) Ambient and fluid temperature Effective area 10.8 mm2 SA Maximum frequency (Mechanical operation type) 300 c.p.m. or less Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
) 2 x 5.5 Without spacer With spacer 2 x M5 thread depth M 15 15 Spacer Grommet: GS Flat terminal: F Conduit: C 280 G F F G 11 300 G F Terminal part Flat terminal connector 11 23 9 H C 15 6.5 H C H C G1/2 Terminal: T DIN terminal: D F G Applicable cable O.D.: 6 to 12 F G Width across flats 22 G1/2 32 (44) H 31.5 25 C H C G1/2 J J Dimensions [mm] Model A B Bs C D E F L M P [inch] Grommet:
A U T O S W I T C H E S A U T OS W I T C H C A P A B L E A U T O S W I T C H 2 Pieces S 1 Piece See Accessories Without Auto Switch D With Auto Switch S T R O K E A D J U S T M E N T S T R O K E ( I N C H) M O U N T I N G With Adjustment Bolts (Std) B With Shock Absorber BC With Cap Type Shock Absorber BCS With One Cap Type Shock Absorber B Housing fixed P End plate fixed 100 1 200 2 300
E 1200 F 1290 G 20 H 720 M16 x l400 Anchor bolt M20 x l500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 4B, 6B 870 M20 x l500 AMF1000 14-20-48
M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2
HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Model Screw type compressor Reciprocating type compressor Screw type compressor 2.2 55 110 7.5 75 22 37 Applicable compressor (kW) 2.2 37 75 7.5 55 15 22 300 8600 18000 1000 12000 3300 5700 (1) Air flow rate l/min(ANR) Reciprocating type compressor 300 5600 11000 1000 8000 2100 4300 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco
Motion on RECL32-300 ML1C REA REC Pressure fluctuation Load fluctuation Speed fluctuation RHC 0.5 0.5 0.3 0.5 Pressure (MPa) Pressure (MPa) Pressure (MPa) Reducing actuation cycle time 10 10 30 10 Load (kg) Load (kg) Load (kg) MTS 100 300 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 CC Max. 500mm/s of high speed transfer is possible.
Selection of applicable model 141 247 283 300 459 200.2 Operating pressure other than 0.5 MPa: Multiply by the following coefficient.
. 600 800 Maximum speed (mm/s) 300 500 30 (13) Stroke (mm) 10 (8) 100 50 150 200 50 100 150 200 20 (9) 30 (10) 10 (11) 20 (12) 8 Selection graph (15) (14) (16) (17) (18) (19) (20) (21) 12 to 40 L: Overhang The distance between the cylinders central axis and the load center of gravity Caution In the case of horizontal mounting, when the load center of gravity is
Collision speed V = 1.4Va Ea = KEmax Workpiece mounting coefficient K: Fig. (3) Max. allowable kinetic energy Emax: Table (1) Kinetic energy (E) Allowable kinetic energy (Ea) ) Correction factor (Reference values) V = 1.4 x 300 = 420 Ea = 1 0.11 = 0.11 Can be used based on E = 0.088 Ea = 0.11 Load Factor 3 3-1 Load factor of load weight Wa = KWmax Workpiece mounting coefficient K: Fig
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Up to 300 Up to 100 Up to 500 Up to 100 Up to 300 Up to 500 Maximum speed (mm/s) (2) 50 (7) 100 (5) 50 (4) 100 (8) 200 (9) 100 (11) 50 (10) (1) 200 (12) 200 (6) Load eccentricity (l mm) (3) Selection graph L: Overhang (the distance from the cylinder
CS1N180A-PS CS1N200A-PS CS1N250A-PS CS1N300A-PS Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed.
Mode automatically changes to Monitor mode when there is no movement of the mouse for 300 seconds on the I/O Configurator. Logged in from Administrator mode, but the I/O setting or pairing setting cannot be performed. 2 Log in again from Administrator mode. Delete the password by entering the master key.
Mode automatically changes to Monitor mode when there is no movement of the mouse for 300 seconds on the I/O Configurator. Logged in from Administrator mode, but the I/O setting or pairing setting cannot be performed. 2 Log in again from Administrator mode. Delete the password by entering the master key.
. : The mode is automatically changed to monitor mode unless a mouse operation is 6 Monitor mode/ Administrator mode performed within 300 seconds in Administrator mode. -12No.EX-OMV0017 3.1.1. Login to administrator mode Password is necessary to login to the Administrator mode. The Initial password is "admin".
Mode automatically changes to Monitor mode when there is no movement of the mouse for 300 seconds on the I/O Configurator. Logged in from Administrator mode, but the I/O setting or pairing setting cannot be performed. 2 Log in again from Administrator mode. Delete the password by entering the master key.
Output Current: 4 to 20 mA (within rated pressure range), Max. load impedance: 300 (power supply voltage: 12 VDC) Current output 2 600 (power supply voltage: 24 VDC) Min. load impedance: 50 , Linearity: 0.2%F.S. (Without sensor), Response time: 150 ms or less Accuracy 1.0%F.S. 1.5%F.S. 2.0%F.S.
-3165-000FL ZS-28-C-5 37104-2206-000FL -12No.PS-OMG0001CN-H
PSE31() PSE30() 2 3 1 (DC(+)) (LINE(+)) (DC(+)) 2 3 (DC(-)) (DC(-)) 4 (OUT15 V) (LINE(-)) (OUT420 mA) A A A -13No.PS-OMG0001CN-H
DC+5 OUT1 4 OUT2 3 2 DC-1
(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.
(For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.