SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-AN-20-V-R"

Operating Pressure MPa How to Order 2 TH0425 TH0806/TH1075/TH1209 TH0604 Metric size TH0604 N 20 1 TH1008/TH1210 Length per roll Indication of tubing model Roll size 20m roll 100m roll Symbol 20 100 0.5 Color indication 0 -20 0 20 40 60 80 100120140160180200 Color Symbol N R BU B Translucent Red (Translucent) Blue (Translucent) Black (Opaque) Operating Temperature C Note) The maximum operating

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

For type R, U, DC voltage is only available. Power saving circuit is only available in the "Z" type. DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Bracket Nil: Without bracket F: With bracket AC (50/60 Hz) 3 port 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

[Option] How to Order Light/Surge voltage suppressor Rated voltage Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) DC CE-compliant 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC For AC voltage valves there is no S option.

(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.

Regarding VP435 (3 position closed center type) Be aware that when the cylinder is in an intermediate stop state, if the supply pressure to the P port is discharged or decreased, this valve is constructed so that the pressure in the cylinder will be discharged to the P port, causing the cylinder to move. 7.

Bracket 2S-22-D With four M3 tappings Digital pressure switch Ser,"es ZSE5 115E5 for general purpose fluid 1 ' How to Order Piping Piping '---r--'I Vacuum pressure switch Positive pressure switch ZSESB L ISESB L Switch specifications t~'1'~"o", 26 Anal 3-wire L Grommct:3m specifications specifications 02 Direct plpmg R(PT)1 /4 T2 Direct pin NPTF 1/4 27 2 out ut NPN 4-wire 67 20ul ul {PNP

[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.

Fixed 0.5 kPa 0.01 mm or less Hysteresis NPN/PNP open collector 1-5 V, 4-20 mA Analog output NPN/PNP open collector Analog output NPN open collector Analog output NPN/PNP open collector Analog output 1 setup NPN/PNP open collector PNP open collector NPN/PNP open collector Analog output NPN/PNP open collector NPN/PNP open collector NPN open collector 2-wire type Output Display (Resolution)

Piping specifications Output specifications Single mounting R 1/8 01 21 NPN open collector 2 outputs without analog output Single mounting NPTF 1/8 T1 0X With suction filter M5 x 0.8 22 NPN open collector 2 outputs with analog output (1 to 5 V) 0XY With suction filter M6 x 1 (Option) Note) Single mounting type: M5 x 0.8 female threaded. 23 NPN open collector 1 output Failure predict function

Description Lead wire color Note 1 DC(+) Brown 12 to 24 VDC Blue (30.8) 2 OUT2 White Switch output 2 24.55 Black 3 DC() Blue 0 V 4 OUT1 Black Switch output 1 When used as an IO-Link device 15 No.

In the case of Fig. (3), ripple 10% means V' V" V'/V x 100 = 10% When no pulsation has occurred, ripple is 0%. V ZSE ISE Vacuum breaking pressure Positive pressure added for releasing the work or quickly returning to atmospheric pressure after breaking the vacuum condition. V' V" PSE V Vibration resistance The amount of vibration a device can withstand without damage.

Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: T (High-pressure Pump Mounted)