Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Double Clevis, Port thread type: Metric, Body Options: Rod-end male thread, Auto Switches: M9B
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Double Clevis, Port thread type: Metric, Body Options: Rod-end male thread, Auto Switches: M9B
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V,12 V 3-wire (PNP) M9PV M9P V V V v v Grommet Solid state auto switch 2-wire 12 V M9BV M9B V V V v v Connector H7C
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
2-wire 12 V Water resistant (2-color indication) MRHQ F9BA Lead wire length symbols: 0.5 m Nil (Example) M9B 3 m L (Example) M9BL 5 m Z (Example) M9BZ Auto switches marked with a symbol are produced upon receipt of order.
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V,12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V,12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 M9PAV1 M9PA1 v v V v
Data
BQ-1 BQ-2 BQ2-012 Mass (g) 1.5 1.5 5 179
Series CHmQB/CHmQWB How to Mount and Move the Auto Switch
M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V, 12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 M9PAV1 M9PA1 v v V
Mass (g) Precautions Caution D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model 0.5 8 8 7 1 14 13 Lead wire length (m) Do not fix the auto switch with screws other than the existing screw installed on the auto switch body.