Bearing Type: Slide Bearing, Bore Size: Ø20 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 125 mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification: Without end lock (standard
thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: U-Shaped Clevis Type, Rod Boot: None, Custom-made Specifications: None, Customized specification (port positions): -, Type: Non-lube, Stroke adjustment symbol: N/A
thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Customized specification (port positions): -, Type: Lube type, Stroke adjustment symbol: -
thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 0.5, The number of the switches: 3, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: Special port location, Customized specification (port positions): BD, Type: Non-lube, Stroke adjustment symbol: -
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 20, Stroke(mm): 125, Max.
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, End Locking: No, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 5, The number of
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, End Locking: No, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number of
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, End Locking: No, Valves: -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, End Locking: No, Valves: -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, End Locking: No, Valves: -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 0.5, The number
type: M Screw, Body Options: Only adjusting bolt with bumper (standard), Auto Switches: A93, Lead Wire Length(m): 5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Shaft Bearing: Slide bearing, Custom-made Specifications: None
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 16, Stroke(mm): 125, Max.
, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Through-Hole / Both Ends Tapped Common (Standard), Rod Tip Shape: Female rod end, Custom-made Specifications: None
, Auto Switches: A93, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Through-Hole / Both Ends Tapped Common (Standard), Rod Tip Shape: Male rod end, Custom-made Specifications: None