Settings and Data Entry 38 10.1 Step Data 38 10.2 Basic parameters 41 10.3 Return to origin parameter 43 11.
Procedures to Trial run . 10 3.1 Checking the contents of the package . 10 3.2 Mounting the controller . 11 3.3 Install the setting software and the driver . 11 3.4 Wiring and connection . 11 3.5 Power supply, Start-up of controller setting software, setting date and time, Alarm and error check . 11 (1) Supplying power . 11 (2) Start-up of controller setting software . 12 (3) Setting date
Input correct data (step data, parameter) again and confirm operation. 3.2 Parts description 11. Setting Data Entry Data writing failure Is the data (step data or parameters) written correctly? 102 - Check the max. speed and acceleration speed of the electric actuator and be sure to input the correct parameters. 11.
[ ] for AC VZ L plug connector (L): SYJ7l2-lLll-01 M plug connector (M): SYJ7l2-lMll-01 VS 11 23.5 11 23.5 13 1.5 13 1.5 A A 25.5 49.7 25.5 49.7 66.9 70.9 [72.2] 300 80.5 (Lead wire length) (Lead wire length) 2-3.2 (Mounting holes) 300 2-3.2 11 23.5 (Mounting holes) 11 23.5 45.1 [51.6] 34 [40.5] 31.1 31.1 21.6 21 28 25 28 21 25 15 15 65.7 10 18 65.7 10 18 [ ] for AC Other dimensions are
(Plug) PA+stroke S G FA FB C+stroke B+stroke A+stroke E MGPM, MGPL/Common Dimensions Standard stroke (mm) Bore (mm) B C DA FA FB G GA GB H HA J K L MM ML NN OA OB OL P PA PB PW Q GC 59.5 37.5 12 12 16 16 10 10 12 12 48 54 64 78 12.5 12.5 112 120 148 162 24 27 32 39 M8 X 1.25 20 20 22 22 M8 X 1.25 6.6 6.6 8.6 8.6 15 34 38 47 55 16 16 20 20 9 M6 M6 M8 24 27 32 39 11 11 14 14 30 30 40 50 34
(Value in the initial state) Base mounted Body ported With Bracket Air operated valve type SYJA3 2-M3-F 1 2 JIS Symbol SYJA312 4 SYJA322 4 Pilot Pressure Range Caution (A) 2 (A) 2 For Safety Instructions and Solenoid Valve Precautions, refer to pages 5-11-2 to 5-11-6. 0.6 1 (P) 3 (R) 1 (P) 3 (R) Pilot pressure (MPa) Pilot pressure range 0.5 N.C.
SOL.a () (+) SOL.a () (+) Light/surge voltage suppressor Light/surge voltage suppressor 17 16 23 22 24 SOL.b () (+) SOL.b () (+) Station 11 Station 8 SOL.b () (+) Station 11 11 SOL.a () (+) SOL.a () (+) SOL.a () (+) 15 21 Light/surge voltage suppressor Light/surge voltage suppressor Light/surge voltage suppressor SOL.b () (+) SOL.b () (+) Station 2 Station 2 15 4 4 SOL.b () (+) SOL.a ()
/32 9/32 1.43 1 1.71 3 5/8 2.36 6.44 5/8 1 15/16 2 1/4 1.81 M16x1.5 200 (2) 5/8 7/16-20 3/4 2.6 1 1/8 3/8 9/16 5/16-24 2 1/2 0.3 3/8 1.26 1.06 11/32 11/32 1.84 1 1.71 3 5/8 2.40 6.44 7/8 1 15/16 2 1/4 1.81 M16x1.5 250 (2.5) 5/8 7/16-20 3/4 3.1 1 1/8 3/8 9/16 5/16-24 3 0 3/8 1.30 1.06 11/32 11/32 2.19 1 1.75 3 3/4 2.48 6.44 1 1/4 1 15/16 2 3/8 1.69 M16x1.5 325 (3.25) 1 3/4-16 1 1/8 3.9 1 1
Fig. 11-2 Status indicators of the EX245-DX1 73 No.EX##-OMY0004 11.6.
10-11 Bit 7 Ch3/7(3) Table 10-11 58 No.EX##-OMY0006CN 10.7.
Refer to Table 5.4-11 Offset setting for details. (1) (2) Offset setting Table 5.4-11 Offset setting No. Indication Item Explanation Setting range (1) Offset Temp.
9.4.1 HRR050-A-20. 9-11 9.4.2 HRR050-W-20. 9-11 9.4.3 HRR050-A-40. 9-12 9.4.4 HRR050-W-40. 9-12 9.5 Heating capacity . 9-13 9.5.1 HRR050-A/W-20. 9-13 9.5.2 HRR050-A/W-40. 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR050-A/W-20. 9-14 9.6.2 HRR050-A/W-40. 9-14 9.7 Required facility water flow (for water-cooled type) . 9-15 9.7.1 HRR050-W-20. 9-15 9.7.2 HRR050-W-40. 9-15 9.8 Types of Hazard Labels
How to Order Specifications 11 MSQ 10 B A90 A S Particle generation grade Grade 1 Note 1) Suction flow rate (example) 1 l/min (ANR) 11-MSQA is identical to the high precision type and 11-MSQB is identical to the basic type. Clean series Vacuum type Number of auto switches Note) Please refer to Pneumatic Clean Series catalog for further details.
B 23 () (+) Gray Red 11 () (+) White Red AXT100-DS25-050 SOL. A When using a standard commercial connector, use a type 25P female connector conforming to MIL-C-24308. Station 11 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Station 12 SOL.
5.5 5.5 11 MY1 H (NN-1) X H G Cross section AA Cross section BB (mm) Model F 20 30 20 28 38 ZZ 48 58 68 90 106 M 42 52 62 84 100 Z 41.5 51.5 61.5 83.5 99.5 K 22.5 32.5 42.5 52.5 62.5 J 17 27 40 50 60 I 10 10 7 19 25 NN 2 2 3 3 4 H 25 35 20 30 24 G 6 6 11 13 17 N 4 4 6 6 6 HA 20 20 20 30 48 GA 11 21 31 43 41 MXS6L-10 MXS6L-20 MXS6L-30 MXS6L-40 MXS6L-50 3.11-29 Series MXS Dimensions MXS 8L
Note 2) Refer to page 11 for dimensions of D-sub communication connector, external pilot and built-in silencer.
10 D-B5/B64 8 9 10 10 11 11 11 10 D-B59W 13 14 14 14 17 16 18 13 D-H7/H7NF/H7W/H7BAL 4 4.5 5 6 6.5 6.5 7 4 D-H7C 7 9 10 9.5 10.5 10.5 11 8.5 D-A3/A44 9 9 10 10 11 11 11 10 D-G39/K39 8 9 9 9 10 10 11 9 4 D-G5/K59/G5W D-K59W/G5BAL/G5NTL Since this is a guideline including hysteresis, not meant to be guaranteed.
J Bore size (mm) Stroke range (mm) A AL B B1 C CDH10 CX D F H1 E I J K L LL D50 63 80 100 +0.070 0 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 35 35 40 40 12 16 20 25 83 83 84 85 98 100 105 110 7 7 11 11 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 18 18 20 20 11 11 13 16 10 10 14 14 40 40 52 52 20 20 25 30 52 64 78 92 27 27 32 41 70 85 102 116 Up to 600 Up to 600 Up to 750 Up to 750 18 25 31.5 35.5
Z ZZ H G 3 +0.03 0 depth 2.5 GA A 15 3.3 3.5 A 5.8 4 x M4 x 0.7 3 +0.05 0 depth 2.5 3 3.5 A-A Model G GA H I J K M Z ZZ 11-MXJ6-5 11-MXJ6-10 11-MXJ6-15 11 17 17 5 17 27.5 42.5 37 43 11 17 17 5 17 27.5 42.5 37 43 Other dimensions are the same as standard model (Series MXJ). 13 22 20 7 20 31.5 47.5 42 48 828 Air Slide Table 11-MXJ Dimensions Basic (Without switch rail) 11-MXJ8-N 12 (Plugged
AS3201F, AS3211F AS3301F, AS3311F AS4201F, AS4211F AS4301F, AS4311F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 12, 13, 16 10, 11, 12 1500 1000 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable