SMC Corporation of America
Elite Part Number Search
Search Results "11-CDJ2B10-125-B"

Do not use only outlet air (dry air) in a closed room. b. Devise a layout which considers the position of the purge air discharge ports. Purge air is humid air. Devise a layout in which the humid purge air will not cause corrosion or malfunction of peripheral equipment. c.

The set values of auto-preset mode are calculated as follows Auto-preset set value Hysteresis mode Window comparator mode P_1 = A (A B)/4 H_1 = (A B)/2 (n_1 = B + P1L = B P1H = A H_1 = 5 digit 1 digit means the minimum set unit (In reversed output, P1L, P1H becomes n1L, n1H respectively) Set A B value 4 in reversed output mode) Refer to the list of output operations (page 26) for the setting

(Refer to fig. b) : Each bit of data sent from master (4 bytes) shows ON/OFF (0: OFF, 1: ON) of solenoid valve.

is nol otfered on trunion or clevis mount cylinders Bore Stsoke O25-1/ainch a37-/eirch Ofi_r/zinch O75 3/ainch Stroke o6 (1h,) O'tO (Es"\ q15 (SB'I % , % , % , % % , % , ' / r , % , ( Y , 1 % 1OO-1 inch 125-11/4inch '{r inch soacer is added to the 1 % inch strcke cylinder o Series NCJP a :Available X : Not available Standard Accessories 8.8 PSI (0.6k97cm.) 20 PSI (1.2kgflcmr) 100 PSI (7kgf

If a single-solenoid valve is mounted on the standard wiring manifold, the output number for the B side valve is skipped. : Custom wiring for mixed mounting single-solenoid valves and double-solenoid valves can be specified with a Wiring Specification Sheet.

Pin Clamp Cylinder C(L)KQG32 Series Compact Cylinder Type 32 How to Order Clamping height LOW type KQG C X2081 B L 32 075 R A L C X2082 KQG C Clamping height HIGH type B L 32 075 R A H C Number of auto switches Nil 2 pcs. S 1 pc.

External Feedback Lever (IP5000 type) Stroke Order Code Unit Number Size M Size N P378010-11 150 125 10~85 mm (Nil) P378010-12 195 110 35~100 mm (E) P378010-13 275 110 50~140 mm (F) DIMENSIONAL DRAWINGS S E R I E S I P 5 0 0 0 / I P 5 1 0 0 IP5000 TYPE: LEVER TYPE LEVER FEEDBACK IP5100 TYPE: ROTARY TYPE CAM FEEDBACK IP5100 TYPE: NAMUR ADAPTER PLATE (Part Number: PAP5100-3) NAMUR MOUNTING

Cable Motor In-line motor type/D type Cable Table D Motor r Lead [mm] t Stroke [mm] LES8 8 4 LES16 10 5 LES25 16 8 Stroke Symbol J K 30 125 150 100 50 75 Model LES8 LES16 LES25 R/L type with lock is not available. u Body option y Motor option Nil S Without option Dustproof specification Nil B Without option With lock For R/L type (IP5X equivalent), a scraper is mounted on the rod cover

JXC-W2 The conversion cable can be used for connecting this controller to the optional teaching box [LEC-T1] offered with the LEC series. or USB cable PC (A-mini B type) (0.8 m) Conversion cable p. 7 1 A conversion cable is also required for connecting the controller to the LEC-W2.

Clean Series: Relief Type, Magnet: Built-in Magnet, Series: J2, Mounting: Basic Style, Bore Size: 10mm, Stroke: 125mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Perpendicular to Axis, Version: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type

Magnet: Built-in, Mounting: Basic Style, Bore Size: 10mm, Stroke: 125mm, Cushion: Rubber Bumper, Head Cover Port: 90° to Axis, Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Low Speed, 5 to 50mm/s

L1 L2 M Nylon Urethane Weight (g) D 1 8 KGF04-01 KGF04-02 KGF06-01 KGF06-02 KGF06-03 KGF08-01 KGF08-02 KGF08-03 KGF10-02 KGF10-03 KGF12-02 KGF12-03 5.6 15 23 11 16 14 11 13 15 17 13.1 13.1 14 27 31 27.5 31 33.5 29 32.5 33.5 34.5 36.5 35 37 41 4 10 5.6 1 4 17 14 17 19 14 17 19 17 19 17 1 8 15 22 25 17 24 24 27 30 36 31 1 4 12 6 3 8 1 8 1 4 3 8 1 4 3 8 1 4 3 8 11 13 14 14 15 8 18.0 18.5 26.1

Master PLC A 3:No Connect 3:GND B 4:RxD/TxD_P 4:No Connect 5:No Connect Item Turning ON Turning OFF RUN Power ONgreen Power OFF DIA Diagnostic errorred Normal BF Communication errorred Normal 6 - System configuration This product is connected to the field bus (PROFIBUS DP) as a slave. Master Power SUP.

Accessory Dimensions 25.7 64 16 54 0.2 5 70 0.2 5 PWR (V) 40 BUS PWR 80 OUTPUT INPUT Cover view 2 x M4 Mounting hole OUTPUT INPUT COM D 60 COM C COM B COM A 1702

Standard Stroke Table Bore size (mm) 20, 25, 32, 40 Standard stroke (mm) 25, 50, 75, 100, 125, 150, 200, 250, 300 Note 1) Intermediate strokes not listed above are also available. Note 2) As the stroke increases, more sliding resistance may result due to the deflection of the piston rod and other factors.

port type Nil Rc Valve stations N NPT 1 Common EXH Bottom Side P Side Side A E T NPTF Side Side 1 0 G F Option 05 5 stations 10 10 stations Dimensions 65 (89.5) [68] 2-7 91 (115.5) [94] Mounting hole n-Rc 1 4 4-Rc 3 8 ( ): DC [ ]: AC, with indicator light n L L1 L2 2 87 100 3 125 138 4 163 176 5 201 214 6 239 252 7 277 290 8 315 328 9 353 366 10 391 404 L1 = 38n + 11, L2 = 38n + 24 n