SMC Corporation of America
Elite Part Number Search
Search Results "VFA3440-02-P"

LED for power supply, LED for alarm 5 to 40C (41 to 104F) Dimensions (mm) 1in=25.4mm LC6C220AD Dedicated teaching box LC51T1 02 TEACH 42 97 POWER ALM PARA AL-RES JOG MON I/O TEST 38 130 STOP SMC LC5-1-T1 TEACHING BOX 96 35 RET ESC/ $MODE 50 21

Description RLQ40 RLQ50 RLQ63 T2 63.4 73.8 80.3 T3 57.8 67.8 74.3 TH 47.9 57.3 57.3 TP Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4 T1 81.4 93.3 99.8 Compact Cylinder with Air Cushion and Lock PT elbow Restrictor PT tee 32, 40: AS2200-(N, F)01-S 50, 63: AS2200-(N, F)02-S 32, 40: KRL06-01SW2 50, 63: KRL06-02SW2 TRB0604W KR-06C 2 Metal speed controller 5 2 Male elbow By-pass tubing Spatter

(mm) Model Applicable fitting size Model KJE02-00 2 KJP-02 2 2 Polyurethane tubing Series TU 2 Miniature fittings Series M

Laterial vacuum entry without buffer series, Pad diameter: 02, 04, 06, 08, 10, 13, 16, 20, 25, 32, 40, 50 (mm), Pad style: flat, flat w/ribs, deep, bellows, Material: NBR, silicon rubber, urethane rubber, flourine rubber, EPR, Rotating or non-rotating, Multiple vacuum entry/mounting thread diameters, Vacuum Pad, with Buffer, VACUUM PAD, ZP, ZP2, ZP3, 58 lb

In most cases, cooling performance of the water-cooled condenser is deteriorated by the contamination of the cooling water of adhesion of scales. (2) Cooling Water Quality Standard 1 Water quality standard As a guideline for cooling water quality which does not cause abnormal level of contamination or scale, JRA-GL-02-1994 Guideline of Water Quality for Refrigeration and Air Conditioning

Piping Piping specification: -02 and -N02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 8 to 12 Nm.

Piping specification: -02 and -N02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 8 to 12 Nm.

ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/4 (8A)10VXZ2232-02--0.70.68.50.442.41.5600

ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/4 (8A)10VXZ2230-02--1.00.78.50.442.41.5550

ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/4 (8A)10VXZ2230-02--1.00.78.50.442.41.5550

ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/4 (8A)10VXZ2230-02--1.00.78.50.442.41.5550

ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/4 (8A)10VXZ2230-02--1.00.78.50.442.41.5550

ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/4 (8A)10VXZ2230-02--1.00.78.50.442.41.5550

Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, Manifold, 5 stations, VACUUM EJECTOR, M82, 273 lb

Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, SPEED CONTROLLER, FLOW CONTROL, SVD, 8 lb

Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, SPEED CONTROLLER, FLOW CONTROL, SVD, 8 lb