SMC Corporation of America
Elite Part Number Search
Search Results "TIUB01Y2-33"

Page 33 Model Selection .Page 37 Flow Rate Characteristics . Page 39 Purge Air Flow Rate Charts ... Page 41 Precautions .

19.8 20.3 21.4 24.4 24.9 26.9 30.9 30.6 34 35.2 38.7 8.4 9.3 11.6 8.4 9.3 11.6 15.2 10.4 12.8 15.2 18.5 28.7 12.7 17.5 M5 x 0.8 8 8 28.8 33.8 25.1 30.1 9.6 9.3 10.8 31.8 13.5 20.6 ASV 17 31.8 12.7 17.5 9.3 13.1 AK 36.1 31.1 32.1 27.1 R 1/8 14.2 14.2 18 21 37.2 41.7 40.1 42.6 45.6 48.4 13.5 18.5 16 17 18.5 21 22.9 28.2 21.9 25.2 28.2 31 10.9 12.9 10.9 12.9 14 16.2 16.2 18.4 18.3 20.2 ASS 33

.: 6, 1/4" (With check valve) (External pilot port) 44.5 Safety limit switch 5.2 (For mounting) 3.5 Made by OMRON 7.5 4.5 33 3.5 108.4 20.5 Precautions Symbols Symbols Specific Product (Max. 10) 224.2 Applicable cable O.D. 3.5 to 7 Safety limit switch (made by OMRON) Part number: D4N-2B31 (G1/2) : D4N-9B31 (M12 connector) 5.2 (For mounting) G1/2 88.8 81.3 (22.9) (With check valve) A 9.4 38.5

No.EX-OMN0013-I PRODUCT NAME SI unit for DeviceNet MODEL / Series / Product Number EX260-SDN# Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 10 Installation 10 Wiring 11 LED Indication and Settings 15 DeviceNet Objects 20 Troubleshooting and Maintenance 28 Specification 33 Specifications 33 Dimensions 35 Accessories

(mm) (mm) F Applicable cylinder E EA EB EC EY FB FC MY1B25 MY1B32 MY1B40 FH 12 FW F Applicable cylinder E EA EB EC EY FB FC MY1B25 MY1B32 MY1B40 FH 16 FW 56 10 49 6.5 53.5 6 33 13 10 57 8.5 57.5 6 43 17 20 46 20 12 61 8.5 67 6 43 17 12 74 11.5 73 8 57 22 25 16 56 25 22 74 15 76 9.5 81.5 6 43 17 15 82 12 87 8 57 22 31 16 56 31 22 74 h S T TT W Shock absorber model MY1B25 MY1B32 MY1B40 a 4.5

No.PS-OMJ0004-E PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ISE35 Table of Contents Safety Instructions 2 Model Identification and How to Order 8 Summary of Product parts 9 Mounting and Installation 10 Wiring 10 Pressure Setting 11 Setting of Function 12 Default setting 12 Other Settings 22 Maintenance 25 Troubleshooting 26 Specification 33 Specifications 33 Dimensions

.-33-r Manifold block O. Joint/clamp O,e . casket O,O . O-ring O,O Non plug-in type @ o End plate (kit) assy MEF363LR-04-t End plates O Joint/clamp O,O . Gasket O,O . O-ring O,O Plug-in type MEF373LH-04-1 End plates O . Joint/clamp O,O . casket O,O .

(Air operated type only) Applicable model Regulator Series IR2000 Series VEX1 33 In the case of multiple pressure control, consider using the E-P HYREG Series VY, which can simplify your system. Caution Caution A B Zero Adjustment Screw The zero adjustment screw has been adjusted at the time of shipment to set the signal pressure and the output pressure as close to 1:1 as possible.

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the Pressure Sensor. Do not perform wiring while the power is on.

CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Type Nozzle model Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 Nozzle size Standard type Nil 01 02 03 04 11 12 13 21 22 23 24 31 32 33

P 500 150 144 400 104 100 300 P 66 43 26 16 90 200 50 56 34 22 14 8 5 100 0 0 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 10 Bore size (mm) Bore size (mm) 1.15-33 Series VY511/VYU5 Precautions Be sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instruction and common precautions on the products mentioned in this catalog.

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the Pressure Sensor. Do not perform wiring while the power is on.

Refer to pages 11 and 12 regarding manifold additions. 8 Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 Dimensions (mm) 1in = 25.4mm VV2DW2 15 ( 25.5) 1 11 Approx. 300 16 4.6 1 24 33 (19.5) 19.5 R2.3 2-1/4 (IN port) 9 4.5 L1 (: Thread type) L2 L3 1 Stations D side 2 3 4 5 n U side VDW23-*G-* VDW23-*G-* VDW23-*G-* VDW23-*G-* 68 31.5 21 18.5 n-M5 x 0.8 n

G Note) Mounting screws are attached. 5 Series ZQ Dimensions K1 type ZQ11U-K113.1 17.6 23 32 4-3.5 Mounting hole Lead wire length (approx. 0.3 m) (49.5) Release flow adjusting screw With L type plug connector 33 25 Suction filter Vacuum pressure switch Bracket A (standard) Supply valve Release valve 62.8 Pilot exhaust port (PE port) Note 4) 2-3.2 through Body mounting hole Note 2) S R U

Symbol Size 33 NPT1/16 34 NPT1/8 35 NPT1/4 36 NPT3/8 37 NPT1/2 Thread connection Applicable tubing O.D.

Refer to page 33 for the noise filter set. Refer to the LECA Operation Manual for installation.

L dimension Weight (g) 348 210.5 198 185.5 173 160.5 148 135.5 123 335.5 110.5 323 98 310.5 298 285.5 273 260.5 248 233.5 223 88 53.3 50.1 46.9 43.8 40.6 37.4 34.3 31.1 84.9 28 81.7 24.8 78.6 75.4 72.2 69.1 65.9 62.7 59.6 56.4 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 No.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions GC GC S + (2 x Stroke) ZZ + (2 x Stroke) ZZ + Stroke (A + B) S + Stroke (A + B) Stroke B Stroke A Bore size (mm) GC 29 33 33 41 41 S 169 181 197 233 253 ZZ 231 250 269 321 342 40 50 63 80 100 GC 29 33 33 41

5.14.1 Pressure unit change . 5-33 5.14.2 Setting/checking of pressure unit change . 5-33 5.15 Data Reset Function . 5-34 5.15.1 Data reset function . 5-34 5.15.2 How to operate reset function . 5-34 5.16 Accumulated Operating Time Reset Function . 5-35 5.16.1 Accumulated operating time reset function . 5-35 5.16.2 How to operate accumulated operating time reset function . 5-35 5.17 Warming

or less VQ1000 VQ1400 40 or less 20 or less 0.68 0.15 0.16 0.72 0.25 0.18 Metal seal 26 or less Exhaust center 77 VQ1401 47 or less 25 or less 0.70 0.20 0.16 1.0 0.30 0.25 Rubber seal 33 or less VQ1500 40 or less 20 or less 0.70 0.15 0.16 0.72 0.25 0.18 Metal seal 26 or less Pressure center VQ1501 47 or less 25 or less 0.85 0.20 0.21 0.65 0.42 0.18 Rubber seal 33 or less A B C Dual 3-port