SMC Corporation of America
Elite Part Number Search
Search Results "52-IP8001-034-M"

Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa

Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

SMC's CG5-S series is a stainless steel cylinder, perfect for use in wash down applications such as food processing machinery requiring intense cleaning.  The use of non-toxic additives allows confident use in equipment for foods, beverages and other products, etc.  The CG5-S can be disassembled, allowing replacement of seals, which promotes an extended service life.  SMC provides plugs

Please contact us for the latest version.sales@ocaire.com, EJECTOR (VJ100-1)-M, VACUUM SERIES, ZX MODULAR VACUUM SYSTEM, AD, ZX NOZZLE SIZE 0.5, .23650 lb

Please contact us for the latest version.sales@ocaire.com, EJECTOR (AIR OP)-M, VACUUM SERIES, ZX MODULAR VACUUM SYSTEM, CD, ZX NOZZLE SIZE 1.0, .23100 lb

Please contact us for the latest version.sales@ocaire.com, EJECTOR (VJ100-2)-M, VACUUM SERIES, ZX MODULAR VACUUM SYSTEM, CD, ZX NOZZLE SIZE 1.0, .22000 lb

Please contact us for the latest version.sales@ocaire.com, FITTING, BARB CLN ROOM, CONNECTORS, M MINI FITTING, C5, M 4MM, .04409 lb

The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications.Simple connection/disconnection, High retaining force, Miniature size, Accepts many styles of plastic tubing, MINATURE FITTING (NETHERLANDS), CONNECTORS, M MINI FITTING, C7, M 4MM, 0.00427 lb

The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications.Simple connection/disconnection, High retaining force, Miniature size, Accepts many styles of plastic tubing, GASKET M5 FITTING (SUS/FKM), CONNECTORS, M MINI FITTING, 25, M NO SIZE RATING, 0.0033 lb

JXD1-M PWR SUPPLY PLUG, ELECTRIC ACTUATOR CONTROLLER, N31, 20.00000 lb

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 3 (w/ HART Transmission Function), Accessories: None (Standard), External Scale Plate: H (w/External Scale Plate), LCD Window: None, Connection, Air - Electric: M (Rc1/4 - M20x1.5), CE Compliant: Q (CE Marked Product)

EX600), SI Unit: EA [EtherNet/IPâ„¢ (2 Ports)], SI Unit Common, End Plate: 4 (Power Supply w/M12 Connector, PNP), I/O Unit Stations: None, Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: DIN Rail Mounting, w/DIN Rail, Combination Manifold: M

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link

Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)