. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation ; Max. inlet air temperature: 122°F (50°C); Max. flow at rated conditions: 2,295 scfm 65m³/min (ANR) @50°F (10°C) PDP; Connections: JIS flanges
Standard strokes range from 5 to 50mm. 10/11-C(D)QS series, available for clean environment, prevents particle generation in a clean room. 21/22-C(D)QS series offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted. The CDQS clean series is auto switch capable.
Please consult with SMC representative for accurate lead times*** Orifice diameters: ø4, ø8, ø10, ø16, ø22; Flow characteristics: 0.35 to 8 Cv; Operating pressure: 0.3 to 0.5 MPa; Fluid temperature: 0 to 100° C; Ambient temperature: 0 to 60° C; Tubing O.D.: Metric size – 6, 10, 12, 19, 25; Inch size – 1/4", 3/8", 1/2", 3/4", 1"
Cooling capacity: 140 W, 320 W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 100 ~ 240 VAC, 50/60Hz ; Circulating fluid: Clear water or 20% ethylene glycol ; Standards: CE, UL, RoHS
PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100, 50-250; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 (flow range dependent); Temperature rating: 0-90°C; Output options: 1-5V or 4-20mA; Accuracy: ±3% F.S. ; Repeatability: ±2% F.S.
PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 10-100, 30-250; Port sizes: 25A (32mm) or 30A (38mm) (flow range dependent); Temperature rating: 0-70°C; Output options: 1-5V, 4-20mA; Accuracy: ±3% F.S. ; Repeatability: ±2% F.S.
PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100, 50-250; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 (flow range dependent); Temperature rating: 0-90°C; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±3% F.S.; Repeatability: ±2% F.S.
PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 10-100, 30-250; Port sizes: 25A (32mm) or 30A (38mm) (flow range dependent); Temperature rating: 0-70°C; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±3% F.S.; Repeatability: ±2% F.S.
Cooling capacity: 230W, 600W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 100 ~ 240 VAC, 50/60Hz ; Circulating fluid: Clear water ; Standards: CE, UL, RoHS
Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 100 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution
Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW, 2.2 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 200 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution
Angle seat structure to minimize pressure loss; 316L stainless steel equivalent material, port sizes: 3/8" to 2"; Optimized flow channel for large flow capability; Easy maintenance; Built-in visual indicator; Fluid temperature: Steam: 183°C or less, Water/Air: 99°C or less
Cooling capacity: 150W; Heating capacity: 380W; Dimensions: 140mm x 160mm x 240mm; Temperature range setting: 4 to 60°C; Temperature stability: ±0.03°C or better depending on load stability; Power supply requirement: 24 VDC ±10%; Circulating fluid: Tap water or ethylene glycol solution (20% or less); Standards: CE/UKCA, UL, RoHS
For high-pressure washing, water spraying, and misting; An IP67 structure with improved environmental resistance; Orifice diameter (mm): 12; Fluid temperature: 1-60°C, ambient -20 to 60°C; Flow rate characteristics (CV): 2.0 (Port size 3/8), 2.2 (Port size 1/2); Easy maintenance, coil can be replaced by simply removing the clip; Available with M12 connection
Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.
Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.
Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.
Magnetically coupled rodless cylinder; Direct mount type; Compatible with secondary battery manufacturing; Bore sizes (mm): 15, 20, 25, 32, 40; Ambient temperature: -10 to 60°C; Auto switch capable
Air cylinder series 90-C(D)J2 miniature cylinders available in double acting and offer stainless steel tubing and stainless steel rods. 90-CJ2 is made from materials compatible with secondary battery manufacturing. 91-CJ2 includes a "Lub-retainer" and is compatible with low dew point (40°C) applications.
Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 100 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution