panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, air cooled, CHILLER, 729, 45
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, ONE-TOUCH FITTING, 949, 5.3 lb
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, 45 DEG MALE ELBOW, ONE-TOUCH FITTING, 949, 45.7 lb
Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), Chemical valve, CHEMICAL VALVE, 2 PORT, B07, 45 lb
Remote monitor unit, Main screen has 2-color display showing flow, status of setting mode and error code, Output display w/indicator light, Display can be rotated in 45° increments, Easy operation and improved visibility, Digital Flow Monitor for Water, DIGITAL FLOW SWITCH, WATER, PF3W, F19, 100 lb
The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Actuator replacements for VM100, VM200, VM400 and VM800, Roller levers, plungers, toggle levers, rod levers, push buttons and twist selectors, MECHANICAL VALVE, MECHANICAL VALVE, I98, 45 lb
The AS*002F speed control series is RoHS compliant.In-line, compact, one-touch fittings , Maximum operating pressure: 1 MPa , Applicable tube material: nylon, soft nylon, polyurethane , Body size: M3, M5, 1/8, 1/4, 3/8 and 1/2, SPEED CONTROLLER, FLOW CONTROL, SVD, 45 lb
Series CJ2 is auto switch capable Direct mount, single acting air cylinder, Compact and lightweight, Bore sizes *: 10, 16, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, Auto switch capable, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.169 lb
Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 1000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 45
Series CJ2 is auto switch capable Non-rotating, direct mount, Single acting, spring return/extend, Bore size *: 10, 16, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, Auto switch capable, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.104 lb
Series CJ2 is auto switch capable Non-rotating, direct mount, Single acting, spring return/extend, Bore size *: 10, 16, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, Auto switch capable, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.104 lb
Remote monitor unit, Main screen has 2-color display showing flow, status of setting mode and error code, Output display w/indicator light, Display can be rotated in 45° increments, Easy operation and improved visibility, Digital Flow Monitor for Water, DIGITAL FLOW SWITCH, WATER, PF3W, F19, 100 lb
The series is available in base mounted or body ported styles.Body ported or base mounted , Rubber seal , Sonic conductance: C - 0.83dm3/(s·bar) , Applicable cylinder size: ø40, VALVE, AIR OPERATED, 4/5 PORT SOLENOID VALVE, VVD, 45 lb
The settings of the master pressur, 2-Color Hi Precision Dig Pres Switch, PRESSURE SWITCH, ISE40, ISE40A, 841, 45 lb
Adjustment range: 0.5 to 3mm.Pin clamp cylinder with positioning and clamping at one time, 55 types of guide pins, 4 body types for a broad range of installation conditions, Optional locking mechanism, Precision adjustment of clamping height is possible by choosing the with shim type, Adjustment range: 0.5 to 3mm, GUIDE PIN, PIN CLAMP CYLINDER, 381, 45 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient & fluid temperature: -10 to 50° C, Enclosure: IP67 (based on IEC529), CIRCULAR CONNECTOR ASSY, 4/5 PORT SOLENOID VALVE, VVD, 45 lb
The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Actuator replacements for VM100, VM200, VM400 and VM800, Roller levers, plungers, toggle levers, rod levers, push buttons and twist selectors, MECHANICAL VALVE, MECHANICAL VALVE, I98, 45 lb
Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 1000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 45
Series CJ2 is auto switch capable Double acting, single rod, end lock cylinder, 16mm bore, Mounting types: basic, axial foot, front flange, double clevis, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, 175, 200, Auto switch capable, BASE CYLINDER, ROUND BODY CYLINDER, 353, 89.47 lb
Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 1000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 45