SMC Corporation of America
Elite Part Number Search
Search Results "ZK2P00K5NL2A-07-B"

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 09 [ø5/16 One-touch

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor]

Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

Stations: 07 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: J (Vacuum Break Flow Adjusting Needle, Round Lock Nut), 1st

Stations: 07 (7 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 07 (7 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Simply install betwwen valve and cylinder; 2-speed control of cylinders; Applicable cylinder: Bore size ø10 to ø40; Stroke from 150mm+; Operating pressure: 0.3 to 0.7 MPa; Tube size: mm 04, 06, 08, 10, 12; inch 03, 07, 09, 11, 13

Simply install betwwen valve and cylinder; 2-speed control of cylinders; Applicable cylinder: Bore size ø10 to ø100; Stroke from 50mm+; Operating pressure: 0.3 to 0.7 MPa; Tube size: mm 04, 06, 08, 10, 12; inch 03, 07, 09, 11, 13

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 4 (-100 to 100 kPa, SI Unit Only, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6

-00 AQ240F-07-07 13.7 13.7 15.4 6.2 13.7 27.3 40.7 8 10.0 15.1 6.2 1/4" 12 6 1/4" 12 40.7 AQ340F-07-00 AQ340F-07-07 16.8 20.3 13.7 16.8 7.1 52.2 33.1 20.0 13 11.8 1/4" 13.2 11 1/4" 13.2 7.1 22.2 15-12-4

The output goes OFF when "B" is turned ON in condition 2. Interlock circuit When either "A" or "B" are ON, output 3 does not go ON even if "C" is turned ON. Output 3 goes ON if "C" is turned ON, only when both "A" and "B" are OFF . OR circuit The cylinder operates if either "A" or "B" is ON.

Sufx for actuator1 Inch size Metric size S Hard steel roller R Red Color of push button, selector B Black G Green Y Yellow 23 3.2 04 4 06 6 01 1/8" 03 5/32" 07 1/4" For selecting applicable tubing O.D., refer to the Model on page 2. Metric size and inch size types can be visually identied by color of the release button.

How to Order P 3 3 01 07 X352 AS F 0 U Flow control With residual pressure relief valve (manual), G thread pilot port With pilot check valve Applicable tubing O.D.

ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. Also, these generators are often smaller and lighter than the bulky vacuum lines used in central vacuum systems. The slim ZU generators are extra compact. A built-in exhaust silencer keeps generator noise to a minimum. Available in

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, EJECTOR SYSTEM, VACUUM SERIES, ZM VACUUM SYSTEM, CC, ZM NOZZLE SIZE 1.0, 0.3858 lb

EJECTOR, VACUUM SERIES, ZM VACUUM SYSTEM, CB, ZM NOZZLE SIZE 1.0, 0.17857 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM UNIT, VACUUM SERIES, ZM VACUUM SYSTEM, FA, ZM NOZZLE SIZE 1.5, 0.33231 lb