Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
Page 4 6 8 10 12 19 1/8" 3/16" 1/4" 3/8" 1/2" Material: Super PFA LQHB LQHB TL TIL TL TIL TL Metric Size TLM TILM TLM TILM P.948 TD TID TD TID TIL Inch Size TH TIH TH TIH Material: PFA 2, 3, 4, 6, 8, 10, 12, 16, 19, 25 TLM Metric Size From page 949 1/8", 3/16", 1/4", 3/8", 1/2", 3/4" 1", 1 1/4" TILM Inch Size 4 6 8 10 12 1/8" 3/16" 1/4" 3/8" 1/2" 4 6 8 10 12 1/8" 3/16" 1/4" 3/8" 1/2" 3/4"
12 12 Bracket ZSE ISE Plug Rc, NPT, G 1/8 SUP port 24 Pressure gauge L3 6.5 ZSP 24 36 36 PS n Stations 1 Left Right ISA2 ISA2 Stations L1 L2 L3 1 46 2 84 38 3 122 38 76 4 160 76 114 5 198 114 152 6 236 152 190 PSE 63(Max. 65) IS 34 5 17 ISG Rc, NPT, G 1/8 (With HW, SW) M4 x 8 Detection port 19 For the bracket mounting position, refer to page 877.
How to Order IZS31 CP X13 L (Tolerance 1%) Cable length 60 L: Cable length Symbol 7 01 02 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19 20 1000 mm 2000 mm 4000 mm 5000 mm 6000 mm 7000 mm 8000 mm 9000 mm 11000 mm 12000 mm 13000 mm 14000 mm 15000 mm 16000 mm 17000 mm 18000 mm 19000 mm 20 mm (Red) 1 12 (6.2) 3 Cable Specifications No. of cable wire 12 0.14 mm2 (AWG26) 0.48 mm Nominal cross section
B 12 B 12 B 12 B 12 7 8 1 2 3 4 5 Valve stations EX600-ED4 1 set EX600-WEN1 1 set EX600-EU1 1 set SS5Y3-10S6WE72-05B-C6 (Type 10 5-station manifold base, Wireless EtherNet/IP) Negative common, M12 connector IN/OUT pin arrangement 1, I/O unit: 2 stations * SY3100-5U1 3 sets (2-position single part no.) * SY3200-5U1 2 sets (2-position double part no.) * EX600-DXPD 1 set I/O unit part no.
(mm) TLM0201 2 x 1 2 1 TLM0302 3 x 2 3 2 TLM0425 4 x 2.5 4 2.5 TLM0403 4 x 3 4 3 TLM0604 6 x 4 6 4 TLM0806 8 x 6 8 6 TLM1075 10 x 7.5 10 7.5 TLM1008 10 x 8 10 8 TLM1209 12 x 9 12 9 TLM1210 12 x 10 12 10 TLM1916 19 x 16 19 16 TLM2522 25 x 22 25 22 TLM1613 16 x 13 16 13 Length per roll Color Translucent Translucent Symbol N N R BU B N N N 10 m Red (Translucent) 20 m Blue (Translucent) Roll
Communication connector D-sub 9 pin (socket) Holding screw: M2.6 6 Contact a for output cutoff alarm (open when alarm occurs) 7 Common for output cutoff alarm 9 15 10 11 12 13 14 Pin no.
x V x C x iT it m x C x (T0 Tt) it Q = = 1 x 250 x 4.186 x 103 x 12 900 = = 13953 [J/s] 14.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 14.0 [kW] x 1.2 = 1 x 250 x 60 x 1.0 x 103 x 12 15 x 860 16.8 [kW] = Thermo-chiller Q x t: Heat capacity [kJ] 13953 [W] = 14.0 [kW] Water bath 20C Cooling capacity = Considering
Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.
Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.
(mm) GC F D BB A 10 16 15 15 15 18.3 12 18.3 14 20 4 5 8 8 5 5 11 11 CA GA BA CB GB 5 5 NN Z 82 83 54 55 M4 x 0.7 M5 x 0.8 S NB NDh8 20.5 20.5 9.5 9.5 10-0.022 0 MM Bore size H 28 28 17 20 NA M10 x 1.0 12-0.027 0 M12 x 1.0 With air cushion With air cushion type is not available for 21-/22-CJ2.
(Values at the initial period) Dustproof Solenoid Specifications Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz Electrical entry AC DC Rated voltage (V) Base mounted Allowable voltage fluctuation Inrush Holding Apparent power (AC) Diode (12 VDC or less: Varistor) Varistor 4.3 W (Standard), 2.3 W (Low wattage
XSA1 4.5 6 XSA2 7 8 XSA3 10.5 11.5 Reverse pressure potential 0.5 MPa(G)*1 Weight New New 18% *1 XSA1-12 (Refer to the Specifications on page 3.) 0.5 kg 0.41 kg lighter *1 Rated voltage *1 XSA2-2 32 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC 24 V, 12 V Applications Photovoltaic cell manufacturing Semiconductor manufacturing LCD manufacturing New New Female thread type (Rc,
(Aluminum: 6.5 g, Stainless steel: 17.6 g) ZNC30 to 80: The weight value is for the basic type without a plug. *6 For pressure sensor details, refer to the PSE540 series in the Web Catalog and the Operation Manual. 6 ZNC Series Lifting Force ZNC20m ZNC30m ZNC40m 12 16 6 14 10 5 12 8 Lifting force [N] Lifting force [N] Lifting force [N] 4 10 6 8 3 6 4 2 4 2 1 2 0 0 0 0 0.6 0.5 0.4 0.3 0.2
The New VXF2 2 port solenoid valve for dust collector has added larger port sizes and has added the flange and flange body type. The VXF2 also has a low noise construction with the option of a silencer. The VXFC controller is dedicated for the VXF2.Larger port size is available, Flange and flange body type added, IP65 enclosure, RoHS compliant, VALVE, MEDIA *LQA, VALVE, VXP
5 port solenoid valve, 4/5 PORT SOLENOID VALVE, 472 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE SOLENOID BASE MOUNTED, VALVE, VZ400 SOL VALVE 3-PORT, PA, VZ400 BASE MT 1/4, .24640 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE SOL, VALVE, VT3/VO3 SOL VALVE 3-PORT, PA, VT3 BASE MT 1/4, .69666 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, BASE MOUNTED, VALVE, VK300 SOL VALVE 3-PORT, NA, VK300 BASE MT 1/8, .28660 lb