CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 140 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 1000 mm 160 180 200 0 100 200 300 400 500 600 700 800 900 1000 Average speed [mm/s] ZK2 Combination Manifold Fittings, Replacement Parts, Tools Manifold Options Specific Product Precautions * Values at extension of a directly coupled cylinder when meter-out speed
MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
In locations at an altitude of 3000 m or higher (Except during storage and transportation) * For altitudes of 1000 m or higher Because of lower air density, the heat radiation efficiencies of the devices in the product will be lower in the location at an altitude of 1000 m or higher.
O~ 0.2 0.3 04 05 0.6 O~ 08 09 00 1000 2000 Auto drain Flow rate /min (ANR) Inlet pressure MPa (Float type normally open) AW4001-04 AW4001 -04 OOrain line should be Bmm or more and should be less than Sm. Be sure not to have any upward turns in the drain line which would prevent drainage. -0.25 H---''t' .:c ' +-+-t---+--r--.
200 1000 2 2 50 200 50 200 3 3 CN1 DC24V 2) USB (A-miniB type ( <> AWG20 (0.5mm 2) (, USB ) LEC-W2 1 2UL ,UL1310 Class2 (3m LEC-T1-3JG* (LEC ) 6.
200 1000 2 2 A-miniB type 50 200 50 200 3 3 CN2 CN2TB/PC 27 - 6.CN4 6.1 No.
style (D-A73C/A80C) and A9/A9 V style: 1000 V AC/min.
MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
M = W x 9.8 (Ln + An)/1000 Corrected value of moment center position distance An: Table (1) Examine Mr. Mr = 0.2 x 9.8 (40 + 15.5)/1000 = 0.1 A2 = 15.5 Obtain Mar = 13 from Va = 300 in Graph (3). Find the allowable static moment Ma (Nm). Pitch, Yaw moment: Graph (2) Roll moment: Graph (3) 13 Find the load factor 1 of the static moment.
(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).
500 3000 0 0 2500 2000 1500 1000 500 3000 Flow rate l/min (ANR) Flow rate l/min (ANR) ARBQ5000-00-P (PA) ARBQ5000-00-P (PB) 0.7 0.7 0.6 0.6 Downstream pressure MPa Downstream pressure MPa 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 2500 2000 1500 1000 500 3000 0 0 2500 2000 1500 1000 500 3000 Flow rate l/min (ANR) Flow rate l/min (ANR) Note: 1MPa = 145psi 1l/min = 0.035SCFM Pressure Characteristics
Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).
-35-D (W1,WF1,M5,C4,C6) ZS-35-F +(01,N01) ZS-35-G +(W1,WF1,M5,C4,C6) -10No.PS-OMM0006CN-E M8(3 ) 01 N M L ISE40A 1/ 2 ISE40A -0.11.000 MPa Y ZSE40A 0.0-101.3 kPa K + T + 1 01 R1/8(M5) N01 NPT1/8(M5) A A D D N NPN1 M8 P PNP1 /M8 1 L M SI2 M8 P (psi)1 1 2kPaMPa 1 ZS-24-A A M35 L,M45 L, 2 ZS-24-D D M35 L,M45 L, 2 / V100-49-1-1 300 mm() V100-49-1-2 500 mm() V100-49-1-3 1000
/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 DC L,M L,M L,M L,M
Then multiply the number by the actual length of pipe, in feet, then divide by 1000. This result is the pressure loss in PSI.
500 500 1000 1500 Flow rate L/min Flow rate L/min (ANR) Flow rate L/min (ANR) SRH4100-03 SRH4110-03 SRH4100-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure MPa Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05 0.1 1000 500 10 5 0 15 20 25 500 1000 1500 0 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min 858 Clean Regulator SRH Series Pressure Characteristics
Then multiply the number by the actual length of pipe, in feet, then divide by 1000. This result is the pressure loss in PSI.
Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160
Cylinder speed-1000 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-Within 100mm (=1000 mm/sec. X 0.1sec.) Take PLC response time into consideration when using.
Note 4) Grommet type (G) is also available for C-kit, single type of VQ0/1000/2000.