DXT170-75-1) Caution Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-111 to 16-1-13 for Precautions on every series. Set the possible min. pressure for adsorption confirmation. If setting the pressure lower than that, switch becomes ON in case that adsorption is not completely done.

DXT170-75-1) 1. Do not use with thinner, carbon tetrachloride, chloroform, acetate, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid and watermiscible cutting fluid (alkaline). 2. Operate it away from direct sunlight.

(Crimping tool: DXT170-75-1) 3. Attaching and detaching lead wires with sockets Attaching Push the socket into the square holes of the connector (with +, 1, 2, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.)

DXT170-75-1) Set point ON When assembling the connector to the switch housing, push the connector straight onto the pins until the lever locks into the housing slot. Hysteresis OFF When removing the connector from the switch housing, push the lever down to unlock it from the slot and then withdraw the connector straight off of the pin.

valve wiring is unnecessary) Timer can be easily adjusted without programming Models Standard supply pressure Nozzle diameter (mm) Diffuser construction Air consumption l/min (ANR) Max. suction flow rate l/min (ANR) Model S M H ZMA05H 0.5 12 18 ZMA07H 0.7 24 23 0.5MPa ZMA10H 1.0 46 36 2 stage diffuser ZMA13H 1.3 95 40 ZMA07M 0.7 16 20 ZMA10M 1.0 0.35MPa 26 32 ZMA13M 1.3 70 36 ZMA13S 1.3 75

Base mounted (With sub-plate) 75 (Without sub-plate 45) Rc(PT)1 /8 4.5 (0.25) SYJA524-01 N.O. SYJA712-01 N.C. Rc(PT)1 /8 9 (0.5) 80 Body ported SYJA722-01 N.O. Base mounted M5 X 0.8 Rc(PT) 1 /8, 1 /4 01 02 01 02 SYJA714N.C. Base mounted (With sub-plate) 130 (Without sub-plate 80) SYJA724N.O.

(Crimping tool: DXT170-75-1) Misc. Power Supply Warning 1. Vacuum pressure switch: The performance is not affected even if a momentary pressure of approximately 0.5 MPa is applied (during a vacuum break). However, make sure that a constant pressure that is higher than 0.2 MPa is not applied.

Lead wire with 4-wire connector P5022-6-1 (0.6 m) P5022-6-2 (3 m) 13-4-23 4 Series ZMA Model H M Standard supply pressure Nozzle diameter (mm) Maximum suction flow rate (l/min (ANR)) 18 24 36 40 20 26 36 38 45 Air consumption (l/min (ANR)) Diffuser construction Model S ZMA05H ZMA07H ZMA10H ZMA13H ZMA07M ZMA10M ZMA13M ZMA13S ZMA15S 0.5 0.7 1.0 1.3 0.7 1.0 1.3 1.3 1.5 12 23 46 95 16 32 70 75

(PVQ31, 33) L 03 04 06 08 16 23 40 0.3mm ( for PVQ13) 0.4mm ( for PVQ13) 0.6mm ( for PVQ13) 0.8mm ( for PVQ13) 1.6mm ( for PVQ31, 33) 2.3mm ( for PVQ31, 33) 4.0mm ( for PVQ31, 33) M G Flow rate characteristics PVQ13-5-04 (24VDC type) at 0.45MPa PVQ3-5G-23 (24VDC type) at 0.35MPa 140 8 7 120 6 100 Flow rate (Lit/min) Flow rate (Lit/min) 5 80 4 60 3 40 2 20 1 0 0 30 40 50 60 70 80 75

Two EPDM 75 durometer O-rings are supplied with each unit. Two O-rings are recommended in case of surface imperfections, damage to an O-ring during assembly, etc. The O-rings must be lubricated with silicone grease during assembly. This not only eases the assembly procedure, it also enhances the sealing characteristics of the O-ring, especially in vacuum applications.

Max. operating pressure Note 1) 2R (MPa) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Note 1) Note 2) Min. bending radius 100 15 25 30 50 65 13 20 24 30 40 50 60 Min. bending radius (mm) Note 3) Fixed end Bending value (Reference) 75 12 20 23 40 48 10 15 18 23 30 40 45 40 to +100C, Water: 0 to +70C (No freezing) Nylon 12 Operating temperature

DXT170-75-1) Unsteady adsorption 1. Do not use with thinner, carbon tetrachloride, chloroform, acetate, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid and watermiscible cutting fluid (alkaline). 2. Operate it away from direct sunlight.

DXT170-75-1) SET2 Indicator light Caution Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. Set the possible min. pressure for adsorption confirmation. If setting the pressure lower than that, switch becomes ON in case that adsorption is not completely done.

Symbol Nominal filtration accuracy (m) Note) Stainless steel 304/Epoxy Stainless steel 316 Polyester/PP Nominal filtration accuracy (m) 0.5 1 2 5 10 20 40 50 70 74 75 100 105 120 X50 001 002 005 010 020 040 050 070 074 075 100 105 120 FGDT, F FGDC, E Note 1) The industrial filter described in this catalog are products in which an element is incorporated into a vessel.

Air, Water, Pure water, Diluent, Cleaning solvent 75 kPa to 0.2 MPa 1.1 mm 10 ms or less (at pneumatic pressure) Zero leakage, either external or internal (at water pressure) 0.3 MPa 0 to 50C 0 to 50C (with no condensation) 18 l Free IP40 or equivalent 20 g 12, 24 VDC 10% of rated voltage Class B Operating pressure range Orifice diameter Response time Leakage Proof pressure Note 2) Ambient

Size (Applicable vacuum pump) 100 (4B) JIS 10K FF flange Symbol Max. exhaust speed (L/min) 3 6 15 37 75 160 360 650 1,500 3,700 7,500 16,000 Specifications Oil mist removal Filtration Maximum operating temperature 99.5% or more 0.3 m (Trapping efficiency: 95%) 80C Model Model Connection R Max. air flow (L/min [ANR]) Applicable vacuum pump Max. exhaust speed (L/min) Weight (kg) Oil accumulation

Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action Port size Lubrication Model Rubber Air 1/8 10-MGF40 10-MGF63 10-MGF100 Relief type (Both sides) Double acting 30, 50, 75, 100 1/4 Non-lube Non-standard intermediate strokes (in 5 mm increments) are available by attaching a spacer of 5, 10, 15, 20 or 25 mm width.

3-phase 380 to 415 VAC (50/60 Hz) Allowable voltage range 10% (No continuous voltage uctuation) Electrical system Applicable earth leakage breaker (Standard) Rated current A 30 20 Sensitivity of leak current mA 30 Rated operating current 50/60 Hz5 A 16/18 8.4/9.1 Rated power consumption 50/60 Hz5 kW (kVA) 4.3/5.4 (5.5/6.0) 4.4/5.6 (5.8/6.3) Noise level (Front 1 m/Height 1 m)5 dB (A) 73 75

, Bronze Resin PTFE, PU, FKM, EPDM, PVC, NBR, POM, PE, NR Power supply 3-phase 460 VAC (60 Hz) Allowable voltage range 10% (No continuous voltage uctuation) Electrical system Applicable earth leakage breaker (Standard) Rated current A 30 Sensitivity of leak current mA 30 Rated operating current5 A 14.2 Rated power consumption5 kW(kVA) 9.1 (11.4) Noise level (Front 1 m/Height 1 m)5 dB(A) 75

Relief type Nil S Bore size (mm) Reed switch Type of auto switch Port type Z73 Solid state switch Y59A,Y59B Type Rc NPT G Bore size Symbol Nil TN TF 40, 63, 100 Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action Port size Lubrication Model Rubber Air 1/8 10-MGF40 10-MGF63 10-MGF100 (Both sides) Relief type Double acting 30, 50, 75