SMC Corporation of America
Elite Part Number Search
Search Results "VHS40-F04A-BS-X1"

SD RD 24 V OV VCAM FG CAM Vt BS+ BDH BDL BSFG 24 V 0 V 24 V 0 V +24V 24G DA DB DG FG Description Description Description LED LED LED PWR. Light ON with transmission power input, light Off without it Green light ON with circuit power input PWR.

air inlet 475 1030 950 direction (Symbol: 3) Ventilation direction (Symbol: 2) Ventilation IDF100150F 6-3 Outer dimensions 6 5 IDX-OM-M050 Air Dryer 6 References 6-4 Electric wiring diagram [IDF100F/125F-30-] GFCI PE TB1 THR MC1 CM OLR MC2 FM1 FM2 PRR HM MC1 SWL PLC TB2 Y0 1 MC1 COM0 2 Y3 3 MC1 Y1 COM3 4 MC2 PRS1 X4 5 P 6 PRR COM1 Symbol Description X0 L CM Refrigerating compressor Y2 THR X1

Switch for setting address X1 and X10 3 B RATE Communication speed The switch to set the communication speed of the controller IF communication line.

BS For minimum strokes for auto switch equipped style, refer to page 530. Applicable Auto Switch/Refer to pages 1719 to 1827 for further information on auto switches. Auto switch part no.

Y axis [Axis speed calculation] Target position Composite speed Composite travel distance =((X2-X1)2+(Y2-Y1)2+(Z2-Z1)2) (X2, Y2, Z2) Xaxis speed = ((X2-X1)/ Composite travel distance) Composite speed Y axis speed = ((Y2-Y1)/ Composite travel distance) X axis Composite speed Z axis speed = ((Z2-Z1)/ Composite travel distance) Current position Composite speed (X1, Y1, Z1) Z axis Caution

BS Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.

Nil B BS With shock absorber (1pc. on port side) The adjustment bolt is installed even when B or BS is selected. (except for 10) Refer to "Auto Switch Guide" (E274-A) for further details on auto switch units. Refer to pages 60 and 61 for auto switch circuit diagrams. Applicable auto switch types Lead wire length (m) Note 1) Load voltage Electrical entry direction Auto switch no.

SD RD 24V OV VCAM FG CAM Vt BS+ BDH BDL BSFG 24V 0V 24V 0V +24V 24G DA DB DG FG LED name LED name LED name PWR Content Content Content Green light turns on when line power is input Turns on during supply of communication power, turns off when there is no input Turns on during supply of communication power, turns off when there is no input PWR PWR Light off: When unit is off-line or power

Single acting nomally open: O.D. holding force, Single acting nomally closed: I.D. holding force Refer to "Effective Holding Force" for the holding force at each holding position, page 13 to 17. 11 Series MHK2 Wedge Cam Operation Gripper Construction Double acting Single acting ck 3 bs br 2 9 Open finger Normally open bt 5 6 bp 8 7 bq 1 4 bl bk bm Closed finger Normally closed bo bn Parts

ZS AS BS . Likewise, if a tube is bent or multiple elbow fittings are used, the piping Output shut off alarm function Jun T TT UT VT . ZT AT BT . resistance will increase and the flow rate will decrease. If the flow rate falls, the temperature stability will decrease.

D-M9mA DC (+) Brown M2.5 x 4L Slotted set screw Main circuit of switch OUT Black Indicator light SMC 4 DC (-) Blue 2.8 2.7 24 D-M9BA 0.2 3 3.2 4 OUT (+) Brown 6 Most sensitive position Main circuit of switch OUT (-) Blue Indicator light/Display method ON OFF Operating range Display Red Green Red Optimum operating position 388 Made to Order Pilot Valve: SF4 SGC 2 2 1 A 05 G 10 1 T Z B1 A L S X1

BS+ 0V 24V FG BSBDH 108.5 (Single) 113.1 (Double) 122 (3 position) ERR. PWR. BDL (108.5) 10 4.6 10 34.3 101 74.5 35 5.5 28.1 12.7 ADDRESS No.

ZS AS BS . This function raises an alarm when temperature of the circulating fluid is out of allowable upper and lower range. When the alarm is raised, WRN is indicated on LCD. If circulating fluid temperature returns to within allowable upper/ lower range, this alarm is automatically cancelled. The allowable upper and lower range of temperature can be set between 0.1 and 10 C.

With 1 shock absorber (Set on the driving cylinder side when packed.) 25 B 32 BS 40 Standard stroke Long stroke * Refer to p.3.8-10 for minimum strokes for auto switch equipped style. Applicable auto switches/Refer to p.5.3-2 for further information on auto switch.

V0V CANL FG CANH V+ 24V V0V CANL FG CANH V+ BDH BS+ BDL BS24V 0V BDH BS+ BDL BS24V 0V 24V Master unit SI unit SI unit DG DB DA DG DB DA DG DB DA End resistance End resistance Master Connector with end resistance VSLD FG FG FG BDH CANL BDL FG CANH Type 3 grounding Type 3 grounding Type 3 grounding V+ Branching crimp connectors Twisted pair line with shielding DeviceNet CompoBus/S System

Front view Mounting holes on the top Mounting holes Theread size Name Type Mounting hole Main body M5 Side Support A Mounting hole M5 Side Support B Mounting Tap M6 x1 Side support A Side support B MY-S25A MY-S25B Mounting holes Mounting taps Installation of work Use 4 threaded holes on the top of slider for installation of work.

Valve Body (for Swagelok) Body (for VCR) Spacer (optional) P 33 Series XSA High Vacuum Angle Valve Dimensions (mm) 1in=25.4mm Electrical entry Grommet (G) Electrical entry Conduit (C) F G 27010 F G D 29010 H C G(PF)1/2 DIN terminal (D) F G J C H 29.5 39 H C OUT IN A P G(PF)1/2 6 to 9 22 E B (body dimension) P (fitting size) 2-M5 Thread depth M A Terminal (T) F G2 (Bs) J (XSA S) 25 33 H K

With Residual Pressure Release Valve Pilot, Silencer/Piping type Symbol Pilot type Built-in silencer Piping direction Internal External Nil V Side S V V R V V V Top RV V VP V V*1 B V Bottom BS V V BR V Vacuum Release Valve with Restrictor BSUP/EXH end block assembly (Includes a) A-e aTension bolt ( ) Tightening torque: 0.8 Nm SY3000: 2 pcs.

2 t r @2 @1 #3 #4 #1 @9 #2 @5 @7 @4 @6 CY1H10 CY1H10-B CY1H10-BS CY1H10@3 @8 #0 t Material Note Component Parts No. 1 2 3 4 No.

1 u u x100 x10 x1 IP address setting switches Switch to set the 4th byte of the IP address by X1, X10 and X100. !7 i !2 i MS, NS Communication status LED Displays the status of the EtherNet/IPTM communication t o ENC z Encoder connector (16 pins) Axis 1: Connect the actuator cable. !0 MOT z Motor power connector (6 pins) !8 @1 !