SMC Corporation of America
Elite Part Number Search
Search Results "PFM550-C8-1-N-W"

25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,

force N Center of sphere R M A B D E F G H Weight kg JC20-8-125 JC30-10-125 JC40-14-150 JC63-18-150 30.5 34 38 47.5 0.03 0.05 0.12 0.23 300 800 1250 3100 13 17 22 27 8 9 13 15 0.5 0.5 0.75 1 7 8 11 13.5 21 24 31 41 4.5 5 6 7.5 7 8 11 14 17.5 19.5 20 25 8 10 14 18 1.25 1.25 1.5 1.5 44 49.5 60 74.5 20 25, 32 40 50, 63 Semi-standard type Pneumatic: to 1 MPa (mm) Maximum thread depth P Allowable

I The dual output applies to NPN, -O~P7:~iP~tio~n~-'-~p~a~m~No~.-.~~===rr-N"~e-_ ~~ =4It PNP, and analog output.

Table 1 shows the tightening torque for reference. LQHB Table 1 Tightening Torque of Union Nut TL TIL 6.

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: J (OUT 1: Analog 1 to 5V; OUT 2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: G [Instantaneous Flow: L/min (gal/min), Temperature: °C/°F], Bracket

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: G [Instantaneous Flow: L/min (gal/min), Temperature: °C/°F], Bracket

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration

(g) n: StationsP, EA, EB portA, B portSS5X7-42SX7 40(R)Single base/B mountCommon SUP/Common EXH2 to 20 stationsBaseSideRc 1 4Rc 1 4C10 (One-touch fitting for ?

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 10 (1), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;

Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: NRZ (N + R + Z)

Body Size: 40A, Thread: N (NPT), Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 30, 40), Semi-Standard 2: NZ (N + Z)

Input Signal: 1 (Current Type 0 to 20 mA DC), Monitor Output: 1 (Analog Output 1 to 5 VDC), Pipe Thread: N (NPT), Port Size: 2 (1/4), Bracket: w/o Bracket, Cable Connector: N (w/o Cable Connector), Pressure Display Unit: 4 (psi)

Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate)

Body Size: 20, Back Flow: w/o Backflow, Thread: N (NPT), Port Size: 02 (1/4), Options: E3 (PNP Output, Wiring Bottom Entry), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl: 2 (Metal Bowl), Bowl Guard: None, Drain Port: J (Body Size 20: 1/8; Body Size 30 & 40: 1/4), Exhaust Mechanism: N (Non-relieving), Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure