(µm): 120, Table Surface Treatment: [Anodize] Hard Anodize, Operating Pressure(MPa): 0.15 to 0.8, Environment: General Purpose, Maximum Load(kg): 38, Operating Speed(mm/s): 100~1000, Allowable Static Moment MA(N⋅m): 15, Allowable Static Moment MB(N⋅m): 9, Allowable Static Moment MC(N⋅m): 2.4, Connection Diameter: Rc1/8, Piping Format: Standard type, Port Screw Type: NPT, Auto Switches: Y59A
Parallelism(µm): 120, Table Surface Treatment: [Anodize] Hard Anodize, Operating Pressure(MPa): 0.15 to 0.8, Environment: General Purpose, Maximum Load(kg): 57, Operating Speed(mm/s): 100~1000, Allowable Static Moment MA(N⋅m): 30, Allowable Static Moment MB(N⋅m): 15, Allowable Static Moment MC(N⋅m): 5, Connection Diameter: Rc1/8, Piping Format: Standard type, Port Screw Type: Rc, Auto Switches: Y59A
Parallelism(µm): 120, Table Surface Treatment: [Anodize] Hard Anodize, Operating Pressure(MPa): 0.15 to 0.8, Environment: General Purpose, Maximum Load(kg): 57, Operating Speed(mm/s): 100~1500, Allowable Static Moment MA(N⋅m): 30, Allowable Static Moment MB(N⋅m): 15, Allowable Static Moment MC(N⋅m): 5, Connection Diameter: Rc1/8, Piping Format: Standard type, Port Screw Type: Rc, Auto Switches: Y59A
Parallelism(µm): 120, Table Surface Treatment: [Anodize] Hard Anodize, Operating Pressure(MPa): 0.15 to 0.8, Environment: General Purpose, Maximum Load(kg): 57, Operating Speed(mm/s): 100~1500, Allowable Static Moment MA(N⋅m): 30, Allowable Static Moment MB(N⋅m): 15, Allowable Static Moment MC(N⋅m): 5, Connection Diameter: Rc1/8, Piping Format: Standard type, Port Screw Type: Rc, Auto Switches: Y59A
µm): 50, Table Surface Treatment: [Anodize] Hard Anodize, Operating Pressure(MPa): 0.1 to 0.8, Environment: General Purpose, Maximum Load(kg): 200, Operating Speed(mm/s): 100~1000, Allowable Static Moment MA(N⋅m): 140, Allowable Static Moment MB(N⋅m): 180, Allowable Static Moment MC(N⋅m): 140, Connection Diameter: Rc3/8, Piping Format: Standard type, Port Screw Type: Rc, Auto Switches: Y59A
Size: 60, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: LR (L + R)
Size: 60, Voltage: 30 (Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ), Options: RT (R + T)
Size: 60, Voltage: 23 (Single-phase 230 VAC, 60 HZ), Thread Type: R (Male), Options: LRT (L + R + T)
Size: 60, Voltage: 23 (Single-phase 230 VAC, 60 HZ), Thread Type: N (NPT), Options: LRT (L + R + T)
Size: 60, Voltage: 11 (Single-phase 115 VAC, 60 HZ), Thread Type: N (NPT), Options: LRT (L + R + T)
Size: 60, Voltage: Single-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ, Options: Cool Compressed Air Output
Size: 60, Voltage: Single-phase 115 VAC, 60 HZ, Thread Type: NPT, Options: Anti-corrosive Treatment for Copper Tube
Please contact us for the latest version.sales@ocaire.com, THERMO-CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 92.59414 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0181700/1900 (50/60 Hz)Air-cooled refrigeration Water-cooled refrigerationSingle-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz) Single-phase 200 to 230 VAC (50/60 Hz)CE/
Please contact us for the latest version.sales@ocaire.com, THERMO-CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 92.59414 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0181700/1900 (50/60 Hz)Air-cooled refrigeration Water-cooled refrigerationSingle-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz) Single-phase 200 to 230 VAC (50/60 Hz)CE/
Special Applications: 10-AR (Clean Series), Body Size: 60, Reverse Flow: No, Thread: N (NPT), Port Size: 10 [1 (Size 50, 60)], Accessory, Not Attached: BG [B+G (Size 20 to 60)], Option: Z (Nameplate/Caution Plate for Bowl in Imperial Units )