SMC Corporation of America
Elite Part Number Search
Search Results "ZK2P00K5CLA-08-K"

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch

Note 2: For guidance on the Fluorocarbon Emission Control Law, please visit our website below. https://www.smcworld.com/products/ja/freon/ 7.2 Refrigerant and GWP value IDF60/70/80/90 Series 7-2 J N M L O K H IDX-OM-V022 Chapter 7 Documents 7.3 Dimensions Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J Unit: mm M N O L K H Unit: mm Model Port Size A B C D

H IDX-OM-W093 7.3 Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J M N O L K H mm A B C D E F G H J K L M N O P IDF60 R1 307 745 605 161 405 681 71 330 704 355 126 46 12. 94 5 IDF70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDF80 R2 438 957 863 169 480 958 219 78 100 11. 0 463 916 485 170 IDF90 13 IDF80 IDF90 mm IDF60 745 957 () () 704 916 () 355

(mg/L) 1.0 or less 0.1 or less 1.0 or less Residual chloride (mg/L) 0.3 or less 0.3 or less 0.3 or less Free carbon dioxide (mg/L) 4.0 or less 4.0 or less 4.0 or less Stability index 6.0 to 7.0 or less Water quality inspection (Once a month) If tap water or ground water (well water) is used as the cooling water for the water-cooled condenser, test the items shown in Table 2 using JIS K

H IDX-OM-V020 Chapter 7 Documents 7.3 Dimensions Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J Unit: mm M N O L K H Unit: mm Model Port Size A B C D E F G H J K L M [N] O P IDFA60 R1 307 745 605 161 405 681 71 330 704 355 126 94 46 12.5 IDFA70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDFA80 R2 438 957 863 169 480 958 219 78 100 11.0 463 916 485

H IDX-OM-V024 Chapter 7 Documents 7.3 Dimensions Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J Unit: mm M N O L K H Power cable entry [IDFB60-11: Power cord with plug, length 110(2800)] Unit :inch (mm) Model Port Size A B C D E F G H J K L M N O P 12.1 29.3 23.8 6.3 15.9 26.8 2.8 13.0 27.7 14.0 5.0 IDFB60 R1 (307) (745) (605) (161) (405) (681) 3.7 (71) 1.8

(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.

U Min. bending radius of lead wire 10 Auto switch K M E J S B + Stroke L + Stroke L A + 2 strokes Note) The drawings above show type D-A7 and D-A8 reed switches. The values shown inside ( ) are for switches other than types D-A7 and D-A8. S and U dimensions for connector type auto switches (D-A7C, D-A80C, and D-J79C) are 7mm greater.

Release piston seal NBR M(D)LUB40, 50 Lead-bronze casting 14 Scraper Hexagon socket head cap bolt A NBR Stainless steel Bumper Urethane rubber 4 Series MLU Dimensions Standard type M(D)LUB40, 50 Rod end female thread Retraction locking GA1 Unlocks when pressurized BP unlocking port Front cylinder port P GC1 MM1 KA (manual unlocking unit) Dust cover NH1 M(D)LUB25,32 (Extension locking) K

through 8-L counter bore 4-K through C B + Stroke J J 8-L counter bore A + Stroke M M CHKDB20 & 25 CHKDB32 to 100 Width across flats f c a b g e h + Stroke Rod end male thread (mm) F L A B C D E G H J K M P Q R Bore size (mm) 20 M8 x 1.25 9.5 depth 5.4 51 43 8 12 10 10 6 30 5.5 43 1/8 16.5 6 25 M10 x 1.5 9.5 depth 5.4 53 45 8 14 12 12 6 36 5.5 49 1/8 17 8 32 M12 x 1.75 11 depth 6.5 61 51

k CQ2 Double Rod Clevis Pin fhldfls$isfirco $enies Handling precautions 1 . Flush away the dust and cutting parlicles in the cylinder tube thoroughly before mounting. 2. Mount the cylinder so that any load applied to the piston rod is always applied in the axial orientation . Ensure concentricity (proper alignment) when mounting the cylinder. .

Stroke (mm) Motor specifications Symbol A B C D G H J K L M N P Motor specifications Mitsubisi Electric Corporation, Yasukawa Electric Corporation, OMRON Corporation Brake 200W without brake 200W with brake 200W without brake 200W with brake 400W without brake 400W with brake 400W without brake 400W with brake 750W without brake 750W with brake 750W without brake 750W with brake 100 10 900

UJ I 2-Forled \bBion DIMENSIONS A B c o E F G H J K M P R s T 1.57 (40) 2.52 (64) 2.20 (56) 1.77 (45) 4.80 (1221 1.97 {50} 0.98 (25) 1 . 1 0 (28) 0.51 (13) 4.45 (113) ?