The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .33069 lb
The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .29619 lb
The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .30864 lb
Please contact us for the latest version.sales@ocaire.com, MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .24250 lb
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CX, IF/PFA 1/8 INCH ALL OTHERS, .85800 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CX, IF/PFA 1/8 INCH ALL OTHERS, .88184 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/8 (6A), MECH VALVE W/ACTUATORS, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), .27485 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum
Type: 000 (Lever Type Feedback), Pressure Gauge: 0 (None), Construction: 1 (w/Terminal Box), Accessories: F (For Stroke 50 to 140mm w/Lever Unit)
Type: 000 (Lever Type Feedback), Pressure Gauge: 1 (0.2MPa), Construction: 0 (No Terminal Box), Accessories: F (For Stroke 50 to 140mm w/Lever Unit)
Type: 000 (Lever Type Feedback), Pressure Gauge: 2 (0.3MPa), Construction: 0 (No Terminal Box), Accessories: F (For Stroke 50 to 140mm w/Lever Unit)
Type: 000 (Lever Type Feedback), Pressure Gauge: 3 (1.0MPa), Construction: 0 (No Terminal Box), Accessories: F (For Stroke 50 to 140mm w/Lever Unit)
Type: 000 (Lever Type Feedback), Pressure Gauge: 3 (1.0MPa), Construction: 1 (w/Terminal Box), Accessories: F (For Stroke 50 to 140mm w/Lever Unit)