SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-AN-10-MT"

Please note that the preset input type is not equipped with an output signal function.

If an abnormal condition occurs, turn off the power supply and stop the flow of compressed air. If an abnormal condition occurs, such as smoke, a foul smell, or noise, immediately turn OFF the power supply and stop the flow of compressed air because there is a possible risk of electric shocks or fire. 2. Do not place your hands or foreign objects inside the unit.

Recyclable marking Europe Secondary battery [When a controller is used for the first time] An alarm will sound 2 times when a battery is connected for the first time. Refer to the Operation Manual for details. When power is supplied to the controller for the first time, please charge the battery for more than 72 hours. -Refer to the Instruction Manual for the signal and wiring. !

Note 2) Impact resistance: No malfunction resulted during an impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature for both energized and deenergized conditions. Vibration resistance: No malfunction resulted during an one-sweep test between 8.3 and 2000Hz.

SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 AC100~240V RS-232C OUT1 to OUT 5 OUT1 to OUT20 (Bank switching) Binary output (31 points) Possible to measure accumulated pulse output of a Digital Flow Switch by an unit of 100 l (litter) and 10 ft3 (cube foot) using the pre-scaling function* of the multi counter (When inputting to the multi counter, Up or Down is selected as

Note 2) Impact resistance: No malfunction resulted during an impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature for both energized and deenergized conditions. Vibration resistance: No malfunction resulted during an one-sweep test between 8.3 and 2000Hz.

In an application where at the end, the stopping position shifting range is larger than the operation range. For example, pushing a work against something, or pressing a work into a hole, or clamping a work. In an application where the auto switch is used to detect an intermediate stopping position. (Detecting time is shortened.)

The design integrates a flow sensor, valve, and control mechanism for automatic adjustment in response to an analog voltage or current signal.  Control is linear and stepless within the rated flow ranges offered.  Features include 10 port options, a dot-matrix LCD color display that rotates 90°, raised rubber setting buttons and an M12 cable connector. 

Note 2) Impact resistance: No malfunction resulted during an impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature for both energized and deenergized conditions. Vibration resistance: No malfunction resulted during an one-sweep test between 8.3 and 2000Hz.