SMC Corporation of America
Elite Part Number Search
Search Results "GA46-2-01"

Actuation: 2 (Normally Open), Piping: 4M (Base Mounted), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (with 1/8 Port Sub-plate)

Body Size: 1, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 01 (1/8), Option: None, Semi-standard: R (Flow Direction: Right to Left)

Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 01 (1/8), Option: BEC (w/Bracket + NPN Open Collector, 1 Output + Analog Voltage Output), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)

Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 01 (1/8), Option: GH (Round Type Pressure Gauge + w/Hexagon Panel Nut, for Panel Mount), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)

Body Size: 1, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: F (G), Port Size: 01 (1/8), Option: G (Round Type Pressure Gauge), Semi-standard: None

Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 01 (1/8), Option: G (Round Type Pressure Gauge), Semi-standard: RVZ (Flow Direction: Right to Left + Downward + Name Plate & Pressure Gauge in Imperial Units: psi)

Body Size: 1, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 01 (1/8), Option: EA (NPN Open Collector, 1 Output), Semi-standard: None

Body Size: 1, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 01 (1/8), Option: G (Round Type Pressure Gauge), Semi-standard: None

Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 01 (1/8), Option: BG (w/Bracket + Round Type Pressure Gauge), Semi-standard: RZ (Flow Direction: Right to Left + Name Plate & Pressure Gauge in Imperial Units: psi)

Body Size: 1, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 01 (1/8), Option: EB (PNP Open Collector, 1 Output), Semi-standard: None

Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 01 (1/8), Option: BEB (w/Bracket + PNP Open Collector, 1 Output), Semi-standard: RZA (Flow Direction: Right to Left + Digital Pressure Switch: With Unit Conversion Function)

Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 01 (1/8), Option: EBH (PNP Open Collector, 1 Output + w/Hexagon Panel Nut, for Panel Mount), Semi-standard: ZA (Digital Pressure Switch: With Unit Conversion Function)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)