Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 3000, 5000 mm; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Speed: 50 ~ 500 mm/sec.; Options include: Heat Resistance 150°C (XB6), Low Speed, 15 ~50 mm/sec (XB9), Ultra Low Speed, 7 ~ 50 mm/sec (XB13), High Speed, 1500 mm/sec (X160),
Bore sizes: 10, 15, 20, 25, 32, 40 mm; Stroke lengths: 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 1000 mm (15 bore), 1500 mm (20 bore), 2000 mm (25, 32 & 40 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Bore sizes: 6, 10 mm; Stroke lengths (6 bore): 5, 10, 15 mm; Stroke lengths (10 bore): 5, 10, 15, 20 mm; Non-rotating accuracy +/-0.1°; Auto switch capable
Bore sizes: 10, 15, 20, 25, 32 mm; Stroke lengths: 150, 200, 300, 400, 500, 600, 800, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1000 mm (20 bore), 1200 mm (25 bore), 1500 mm (32 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 70 ~ 300 mm/sec.
The arm opening angle ranges from 15° to 135° and can be easily changed by replacing the stopper body. Available in 50 and 63 bore sizes. Complies with NAAMS standard (CKZ3N); 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; 75 types of arm variations (CKZ3N); Metal cover and metal switch cassette options available; Optional manual handle operator (X2568) available
Bore sizes: 6, 10, 15, 20, 25, 32, & 40 (mm); Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500 mm; Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 400 mm/sec.; Options: XB9 - Low Speed (15 ~ 50 mm/sec.), XB13 - Ultra Low Speed (7 ~ 50 mm/sec), ; Auto switch capable
Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW (60Hz); Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15 kW); ±1.0°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010). This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.
Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010). This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.
Total cooling capacity: 9.5kW (air)/11.0kW (water) (CH1 oscillator, CH2 optical system combined); Power supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase; Power supply "40"; 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase; Temperature set range: CH1 = 15 to 25°C, CH2 = 0 to 15°C; Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C; Refrigerant: R410A; Communication: contact/analog
Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW, 38 kW; Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15, 38 kW); ±0.1°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
The arm opening angle ranges from 15° to 135°and can be easily changed by replacing the stopper body. Available in 50 and 63 bore sizes. Compiles with NAAMS standard (CKZ5N); 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; Easier mechanism unlocking; Space-saving and lightwieght; High clamping force
The arm opening angle ranges from 15° to 135° and can be easily changed by replacing the stopper body. Available in 50 and 63 sizes. High clamping force; 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; Easier mechanism unlocking; Space-saving and lightweight
, 15?, 22? ; Circulating fluid recovery tank: 15? to 17?
, 15?, 22? ; Circulating fluid recovery tank: 15? to 17?
Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 3000, 5000 mm; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Speed: 50 ~ 500 mm/sec.; Options include: Heat Resistance 150°C (XB6), Low Speed, 15 ~50 mm/sec (XB9), Ultra Low Speed, 7 ~ 50 mm/sec (XB13), High Speed, 1500 mm/sec (X160),
Bore sizes: 6, 10, 15, 20, 25, 32, 40 mm; Stroke length: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500 mm; Minimum operating pressure: 0.18 Mpa (26 psi); Speed: 50 ~ 500 mm/sec.; Options: XB9 - Low Speed (15 ~ 50 mm/sec.), XB13 - Ultra Low Speed (7 ~ 50 mm/sec.); Auto switch capable
Bore sizes: 10, 15, 25 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1200 mm (25 bore); Minimum operating pressure: 0.2 MPa (29 psi); Speed: 50 ~ 500 mm/sec.
Bore sizes: 10, 15, 20, 25, 32, 40 mm; Stroke lengths: 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 1000 mm (15 bore), 1500 mm (20 bore), 2000 mm (25, 32 & 40 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Bore sizes: 10, 15, 20, 25, 32, 40 mm; Stroke lengths: 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke lengths: 500 mm (10 bore), 750 mm (15 bore), 1000 mm (20 bore), 1500 mm (25, 32 & 40 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.