46 33 12 198 36 77 32 58 36 66 19 30 38 31 13 1/2 69 50 18 74 115 153 80 25 to 800 10.5 M33 x 2 57 32 15 223.5 M10 x 1.25 45 96 41 75 45 74 13 41 35 42 17 1/2 77 60 17 80 133 168 100 25 to 1000 14.5 M42 x 2 58 42 15 257.5 M14 x 1.5 56 115 52 90 56 86 16 50 41 38 19 3/4 79 72 22 97 146 187 Transaxial foot: CHSDLA PJ + Stroke Y J MM S + Stroke H B 2 x RcP GB GA Air release LY D E V V LH LT X1
F '-1: M6 x1 M:U8xt25 y Model C 0 M G I.. G Deep type (mm) H:M5xO.8 H:t.(lXI25 "B H:MSxt y M_I F C 0 E "A G ...
-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X1-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X2-B01-B10 ZPA-X2-N01-B10 ZPA-X2-T01-B10 ZPA-X2-B01-B12 ZPA-X2-N01-B12 ZPA-X2-T01-B12 ZPA-X2-B01-B10 ZPA-X2-N01-B10 ZPA-X2-T01-B10 ZPA-X2-B01-B12 ZPA-X2-N01-B12 ZPA-X2-T01-B12 ZPA-X3-B01-B10 ZPA-X3-N01-B10 ZPA-X3-T01-B10
G H I A B C D E F Model How to Order 33 42 44 50 61 28 30 36 44 54 45 55 63 69 81 59 78 107 110 134 20 29 39 42 53 40 53 70 75 90 34 46 63 67 78 22 21 26 45 55 58 65 76 VHS20 VHS30 VHS40 VHS40-06 VHS50 30 03 RZ F VHS 3-port valve for residual pressure release Caution 1. Consult SMC when a pressure switch and T type spacer are installed on the outlet of pressure release valve 2.
Y1 S + Stroke Y1 X1 BB Z + Stroke Width across flats G ZZ + 2 strokes (mm) Bore size (mm) Stroke range (mm) B BB GA LX P LW LT F J LH NA T SS S Z X1 C Y1 R M CD 32 25 to 800 M10 x 1.25 32 39 30 37 222 40 3/8 8 40 11 32 11 220 158 16 11 38 58 62 13 0.15 0.13 40 25 to 800 32 M10 x 1.25 33 42 36 222 46 3/8 43 8 11 32 220 11 12 158 45 11 69 65 13 50 25 to 800 M10 x 1.25 40 46 37 43 246 58 1/
The input block, end block and DIN rail are included in the input manifold. 8 stations 8 Applicable GW unit Applicable GW unit DeviceNet PROFIBUS-DP Remote I/O (RIO) DeviceNet PROFIBUS-DP Remote I/O (RIO) Nil Nil -X1 -X1 With waterproof cap Input block specifications Input block specifications Current source type input block (PNP input block) or Current sink type input block (NPN input block
Table. 4-7 Valve protection function Count X1 Valve protection Description During operation of energy saving function, if the switching of vacuum generate/stop has reached Count X1 times, stop subsequent energy saving function. Energy saving function resumes by turning PWR or PWR(V) OFF/ON or RecordData access.
+ Stroke BA 2-BT (mm) Stroke range Model A BY D GW GY H H1 B1 C B AL BA BB BP BS BT ET GA GA1 GB GC GC1 EY 22 26 30 35 19.5 23.5 27 32 24 28 32 39 8 6.5 9 12 9 6.5 8 10 17 19 22 27 MLUB25 MLUB32 MLUB40 MLUB50 M5 x 0.8 73 87 87 102.5 M5 x 0.8 depth 7.5 M6 x 1 depth 12 7 8 9 9 12 14 16 20 M5 x 0.8 depth 11 M6 x 1 depth 11 45 50.5 53 62 45 51.5 53 62 10 8.5 9 11.5 15.5 17.5 18.5 23 32.5 37
Select x1, x2 or x4 with the UP/DOWN keys. x4 indicates multiplication by 4. Shift to the next item with the SEL. key. DOWN SEL. key (4) Setting the prescale value FUNC. Set the number to be added for each count. Shift the digits with the LEFT/RIGHT keys, and increase or decrease the numerical values with the UP/DOWN keys. Shift to the next item with the SEL. key.
Configuration table][ ][Properties] (2)[Parameters] (3)[Value] (4)[OK]PLC (1) (1) (2) (2) (3) (4) (3) -62No.EX-OMQ0015CN FSU(First Start Up) EX600FSU FSUPLCFSU PLC (1)[HW Config]EX600 PLC PROFINET [Properties] (2)[Options] (3)[Connection][TP 100Mbps full duplex] (4)[Disable autonegotiation] (5)[OK] (1) (2) (3) (4) (5) -63No.EX-OMQ0015CN EX600 (1)[HW Config]EX600-SPN# (2)[Configuration table][Slot X1
@Sffi' 13 $ut'ies CDI2BP ilhl ttal||elic tiold Bs$islorc 4. Do not drop, dent, or allow excessive impact to cylinder during handling. 5, Keep at least 20mm away from each other when 2 or more cylinders with high magnetic field resistance auto 3. switch are mounted in parallel. up, although the auto switch will function.
ends) Note: Minimum impact velocity tor PM nlodels it 4 itr/*c. 9k**k &"bs*rbers Non-Adjustable Hydraulic Series 49rc.
AD38-D AD48-D p. 48 p. 48 Accessory Spacer Y200-D Y300-D Y400-D Y500-D Y600-D Spacer with bracket Y200T-D Y300T-D Y400T-D Y500T-D Y600T-D VHS40-m02-D VHS40-m03-D VHS40-m04-D VHS40-m06-D VHS50-m06-D VHS50-m10-D Pressure relief 3-port valve*5, *6 VHS20-m01-D VHS20-m02-D VHS30-m02-D VHS30-m03-D p. 49 E400-m02-D E400-m03-D E400-m04-D E400-m06-D E600-m06-D E600-m10-D E600-m12-D E600-m14-D Piping
Symbol Symbol -X1 1 Rod End Female Thread -X2 2 Intermediate Stroke Mounting Rotating angle MRQ Mounting Stroke Cushion Auto switch Rotating angle S X X1 32 40 MRQ Stroke Cushion Auto switch S X X2 32 40 Rod end female thread Intermediate stroke Operating stroke For intermediate strokes other than standard strokes, the full length is shortened by cutting the linear motion side according to
Model no. 1 3 5 A VZ X1 ( ) VZ3 A ( ) Manual override Entry is the same as standard products. Entry is the same as standard products.
Company Bs PLC I/O card Connector pin assignment (pin layout) Company As PLC I/O card Connector pin assignment (pin layout) Change of PLC manufactures (Company A to Company B) + + + + 2F 2E 2D 2C 2B 2A 11 13 15 17 19 1B 1D 1F 21 23 25 27 29 2B 2D 2F 29 28 27 26 25 24 23 22 21 20 + + 19 18 17 16 15 14 13 12 11 10 + + 1F 1E 1D 1C 1B 1A 10 12 14 16 18 1A 1C 1E 20 22 24 26 28 2A 2C 2E General
4 11 34 15.5 30.5 33 16.5 19.5 20 4, 6 14 17 35 Port size M5/M6 Grommet Y W 2 x 3.4 Mounting hole U X U1 X1 D Q F 300 Full wave rectifier (AC type) R E C (mm) Model Port size P B B1 E C D F 20 VDW1 VDW2 M5(M6) 20 10 46 15 9.5 11 2 x P Port size B1 M5(M6) 22 11 51 9.5 13.5 B Mounting bracket dimensions Electrical entry Model Port size P Grommet U U1 X1 Y W X Q R 39 VDW1 VDW2 28 14 17 17 M5
EX245-DX1 2Byte Table 11-3 X0 X1 X2 X3 X4 X5 X6 X7 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 72 No.EX##-OMY0006CN 11.5. LED EX245-DX1 LED 0 15 OFF ON Fig. 11-2 EX245-DX1 LED 73 No.EX##-OMY0006CN 11.6.
Yaxis [Axis speed calculation] Composite travel distance =((X2-X1)2+(Y2-Y1)2+(Z2-Z1)2) Xaxis speed = ((X2-X1)/ Composite travel distance) Composite speed Y axis speed = ((Y2-Y1)/ Composite travel distance) Composite speed Z axis speed = ((Z2-Z1)/ Composite travel distance) Composite speed Target position Composite speed (X2, Y2, Z2) X axis Current position (X1, Y1, Z1) Z axis Caution Setting
X1 0.2 MPa, 0.4 MPa and 0.8 MPa settings can be combined. Set pressure Accessory (Pressure gauge) G33--01 (IR1000), G43--01 (IR2000) Non-grease specifications Note 1) Regulators to be manifolded are counted starting from stations 1 on the left side with the OUT ports in front.