Series: 10-SV1000, Base Type: 10FD, Connector Entry Direction: Upward, Valve Stations: 8 Stations, P, E Port Location: Both Sides, 2-20 Stations, Pilot Type: Internal Pilot, A, B Port Size: One-touch Fitting for Ø1/4, Mounting: DIN Rail Mounting w/o DIN Rail
Series: 10-SV3000, Base Type: 10FD, Connector Entry Direction: Upward, Valve Stations: 8 Stations, P, E Port Location: Both Sides, 2-20 Stations, Pilot Type: Internal Pilot, A, B Port Size: One-touch Fitting for Ø1/4, Mounting: DIN Rail Mounting w/DIN Rail
Series: 10-SV1000, Base Type: 10FD, Connector Entry Direction: Upward, Valve Stations: 8 Stations, P, E Port Location: Both Sides, 2-20 Stations, Pilot Type: Internal Pilot, A, B Port Size: One-touch Fitting for Ø6, Mounting: DIN Rail Mounting w/o DIN Rail
Series: 10-SV4000, Enclosure: Tie Rod Base, SI Unit: W/out SI Unit, Valve Stations: 8 Stations, P, E Port Location: Both Sides, 2-16 Stations, SUP/EXH Block Assembly Specifications: Internal Pilot, A, B Port Size: NPT 1/4, Mounting: DIN Rail Mounting w/DIN Rail
(Displays 0 when the value is below 20 L/min) 60 to 2100 L/min 30 to 1050 L/min (Displays 0 when the value is below 60 L/min) 3.0 0 to 3%F.S. (Displays 0 when the value is below 30 L/min) 80 to 2100 L/min 40 to 1050 L/min (Displays 0 when the value is below 80 L/min) 4.0 0 to 4%F.S.
-10 oC to 60 oC (With rod boot of nylon tarpaulin) (No freezing) Ambient temperature Fluid temperature -20 oC to 60 oC (No freezing) Operating humidity 35 % to 85 % (No condensation) Installation altitude 0 m to 5,000 m Housing protection IP67 Standard CE,UKCA, RoHS compliant Weight Refer to Table 1.
An example is shown below: Set circulating fluid temperature: 20 oC READY bandwidth (range between the upper and lower limit temperatures): 2 oC READY time: 60 seconds Preparation for operation will be completed 60 seconds after the circulating fluid temperature reaches the range of 18 oC to 22 oC. Shorter than 60 sec. 60sec.
Arm angle [] Bore size [mm] 15 30 45 60 75 90 105 120 135 0 0 0 0 0 0 0 0 0 75 90 105 120 135 50 15 30 45 60 -3 -4 -5 -5 -5 -5 -5 -6 -9 1 0 0 0 0 0 0 0 0 75 90 105 120 135 63 15 30 45 60 -3 -4 -5 -5 -5 -5 -5 -6 -9 (7) Do not disassemble the power clamp cylinder. The power clamp cylinder consists of a completely sealed structure in order to protect it from welding spatter.
mm/s] 2,000 2,000 2,000 Acceleration/deceleration [mm/s2] 20,000Note3) Positioning repeatability [mm] 0.06 Lost motion [mm] 0.1 or less Lead [mm] 54 54 54 Impact resistance/vibration Resistance [m/s2] Note 4) 50 / 20 Drive method Belt Guide type Liner guide Operating temperature range [] 5 to 40 Operating humidity range [%RH] 90 or less (No condensation) Motor output/size 100W / 40 200W/60
12mm 5mm Step Axis 1 Step No. 1 Posn 12 .00mm Force 40% Step Axis 1 Step No. 1 Posn 5 .00mm Force 40% 60 5 SET SET P.2735 5.3 10 - (5) 2.
60 60 Moving force 100 100 100 Area1 0.00 0.00 0.00 Area2 0.00 0.00 0.00 In position 1.00 1.00 1.00 90 - LEFB Basic parameter default Model LEFB16 LEFB25 LEFB32 Lead[mm] 48 48 48 Controller ID 1 1 1 IO pattern 1 1 1 Acceleration/ Deceleration pattern 1 1 1 S-motion ratio 0 0 0 Storoke(+) Storoke +2 Storoke +2 Storoke +2 Storoke(-) -2 -2 -2 Maximum speed 1100 1400 1500 Maximum acceleration
HECR008-W HECR012-W 1 Unused BUS + 0 0 Operation temp. range 10.0 to 60.0 C (No dew condensation) 5 4 3 2 1 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 During operation or maintenance of the product, do not disable the Communication Indication temp. range -9.9 to 80.0 C 2 RXD (RD) Unused Circulating fluid temp. deg.C Circulating fluid temp. deg.C connector Temp: 10 to 35 C Humidity : 35
25 45 60 A Applicable clamp cylinder A Applicable clamp cylinder Part no.
, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes other than the above are produced upon receipt of order.
Port size (A port) Rated voltage Option M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Nil None With bracket (Not assembled) P, R port: M5 4 5 6 24 VDC 12 VDC F Thread type 7 240 VAC, 50/60 Hz 9 Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800
1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 240 VAC, Hz Other (Without connector) 50 60 50 60 50 60 4 5 6 7 50 60 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9 Option Port size M5 x 0.8 Rc 1/8 (A port) M5 01 Body ported (Single type
(Values at the initial period) VT325-C VT325-G JIS Symbol Solenoid Specifications Grommet, Conduit, DIN terminal, Conduit terminal 100, 200 VAC, 50/60 Hz, 24 VDC 15 to +10% of rated voltage 75 VA 60 VA 27 VA 17 VA 12 W Electrical entry Coil rated voltage Allowable voltage fluctuation 50 Hz 60 Hz 50 Hz 60 Hz Inrush AC Apparent power (3) Holding DC Power consumption (3) Note 3) At rated voltage
SZ3 60(R) X90 U side Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Entry is the same as standard products. Specifications and performance are the same as standard products.
Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.
68 77 85 MGF 0UT 201 40 60 80 101 121 141 161 181 201 Symbol Specifications 16 8 MGZ IN 151 30 45 60 76 91 106 121 136 151 XA Change of rod end shape Heat resistant cylinder (10 to 150C) XB6 0UT 314 63 94 126 157 188 220 251 283 314 20 10 MGT XB9 Low speed cylinder (10 to 50 mm/s) IN 236 47 71 94 118 142 165 189 212 236 XB10 Intermediate stroke (Using exclusive body) 0UT 491 98 147 196 246