Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 237, 1.25 lb
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 1.3 lb
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 1000 SERIES 5 PORT VALVE, 4/5 PORT
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3 PORT BASE MOUNTED SOLENOID VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient & fluid temperature: max. 50°C, SOL.
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 237, 1.3 lb
, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, MANIFOLD BLOCK ASSY, 4/5 PORT SOLENOID VALVE, VVD
, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, 5 port solenoid valve, 4/5 PORT SOLENOID VALVE, VVD, 120 lb
, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, 5 port solenoid valve, 4/5 PORT SOLENOID VALVE, VVD, 141 lb
, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, 5 port solenoid valve, 4/5 PORT SOLENOID VALVE, VVD, 141 lb
, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, 5 port solenoid valve, 4/5 PORT SOLENOID VALVE, VVD, 148 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1060 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1700 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 1890 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, I50, 2020 lb
, Ambient & fluid temperature: -10 to 50°C, 5 port plug in valve, 4/5 PORT SOLENOID VALVE, J55, 67 lb
, Ambient & fluid temperature: -10 to 50°C, 5 port plug in valve, 4/5 PORT SOLENOID VALVE, J55, 67 lb
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 2000 SERIES 5 PORT VALVE, 4/5 PORT