(N) and (P+) (N-)) of the main circuit converter is displayed. 0 to 900 V 19 Station No.
Operating pressure P (MPa) P 0.7 MPa MTS 4.
Y69B Y7NWV Y7PWV Y7BWV IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Relay, PLC Diagnostic indication (2-color indication) 5 V, 12 V Grommet 24 V 2-wire 12 V Water resistant (2-color indication) Y7BA Solid state switches marked with are produced upon receipt of order.
MC NFB Servomotor HC-PQ Power supply Single phase 200VAC (Type A) or Single phase 100VAC (Type A1) C P U L1 U V V W Servo amp SM L2 W MR-CA E or MR-CA1 The length of the cable between the controller and servo amp is 2m or less.
B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when workpiece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when workpiece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the workpiece for a few times. The optimum values will be set automatically.
Note Bracket B and the bracket assembly make up one set. DOWN OUT1 U P SET ZS-31-A Bracket Note: Mounting screws are not included.
: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5.5 S T K (3.3) D 4-G through R + Clamp stroke X Z C 0.2 2 x 4-H counterbore Q + 2 x Clamp stroke + 0.15 + 0.05 2-3.3 depth 3 K A P Both ends tapped style: MKA A thread (mm) A B Model MKA MKA50 MKA63 32 40 10 M6 x 1.0 14 M8 x 1.25 18 M10 x 1.5 R + Clamp stroke (Basic) (mm) Q A G I J S T B H K L O U C P V D E R X
(Resin or rolled steel) LVariation Standard stroke (mm) Bore size (mm) Series Mounting Action Rod end configuration Standard variation Built-in magnet Locking Cancel cap Proximity switch Option 15 20 30 40 20 32 50 63 80 P P P P P P P P P P P P P P P P P P P P P P P P P Double acting Lever style Double acting with spring RSH Flange Adjustable Single acting 4.3-1 Heavy Duty Stopper Cylinder
A) 4 (B) 2 (A) 4 (B) 2 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) Note) Except VQZ1000 and metal seal type.
One-touch fitting) (Pitch) P=12.5 19.5 2n-M5 0.8 (A, B port) Q 1 2n-One-touch fitting (A, B port) (Pitch) P=12.5 19.5 5 Q B B 15 1 29.8 A A 5 B B Q 15 29.5 A A (Non-locking) Manual override L1 Q L2 4 Manual override (Pitch) P=12.5 14.5 (Non-locking) Q 24.5 (Mounting holes) 64.3 47.3 45.5 35.3 Q 10 16 4.5 33.5 16.5 63.3 1 17 7.5 36.5 MAX.5 P A A A A A A 10 P Q 31.5 B B B B B
San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Exhaust port Rc 1 25 Vacuum pressure gauge Exhaust port With vacuum pressure gauge ZL212-G P V Exhaust port Vacuum adapter Rc 1/8 7 With vacuum adapter ZL212-GN P V Vacuum pressure switch Exhaust port With digital vacuum pressure switch ZL212-E P V RESETSET ~ = ~ = 500 (L
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
(N) and (P+) (N-)) of the main circuit converter is displayed. 0 to 900 V 19 Station No.
-01 12.7 20.4 27.5 9.3 4 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 14.3 13.5 20.4 27.5 11.6 6 5/32" 14.2 31.1 36.1 12 32.1 27.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 12.7 14.3 23.1 30.2 19 18.5 25.3 32.4 15.2 11.4 36.1 8 3/16" 31.1 32.1 27.1 16.5 14.2 AS221FG-01-10 AS221FG-N01-07 23.9 31 15 21 21 33.1 40.2 18.5 13.2 10 1/4" 18.5 19 AS221FG-02-04 AS221FG-N01-09 15
B) 2 FJG Option 1 (P) 5 (R1) 3 (R2) None Light/Surge voltage suppressor Individual pilot exhaust Nil Z V (A) 4 (B) 2 When two or more symbols are specified, indicate them alphabetically.
) B54 100 V, 200 V Yes Yes 24 V B73C C73C 12 V 2-wire Diagnostic indication (2-color indication) PLC (B59W) B59W Grommet G79 H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) Grommet K79 K79C 2-wire 12 V Connector Relay, PLC 3-wire (NPN) IC circuit 24 V Diagnostic indication (2-color indication) 5 V, 12 V 3-wire (PNP) Grommet 2-wire Water
ML2B32 15N Va 0.25m/s 0.5MPa L1 0.05m L2 0.05m W W 1 L L1 W W W M We M3 V M1 V <> W max=60N( Va P 19) a1= W = 15 =0.25 W max 60 M 2 max=2Nm( Va P 19) a2= M = 0.75 =0.375 M max 2 <> We=1.410VaW=1.4100.2515=52.2N M max=3.5Nm( V=1.4Va) M 3 WeL 1 =52.50.05 1 =0.88Nm 3 3 a3= M 3 = 0.88 =0.25 M 3max 3.5 M max=12Nm( V=1.4Va) M 1 WeL 1 1 =52.50.05 1 =0.88Nm 3 3 a4= M 1 =
) Y7BA P.12 Lead wire length symbols: 0.5m .
P R B B B B B 43.9 24 24 44 23 A A A A A 10.5 0.5 (DIN 1.7) 33 10.4 15.9 ( DIN 17.1) 1/4 (P, R port) 1/4 (P, R port) (Pitch) P = 17 24.5 (Station n) (Station 1) (Station n) (Station 1) Built-in speed controller (Light/surge voltage suppressor) (Light/surge voltage suppressor) 56.5 Max. 13.5 61.6 [68.6] 61.6 [68.6] + + + + + + 46.2 46.2 A A A A 33 24.5 25 B B B B 1 6 8.5 8.5 (Pitch) P = 16