Search Results "ZSE20B-L-P-N01"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: w/o Operation Manual, w/o Calibration Certificate

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: w/o Operation Manual, Calibration Certificate

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: Operation Manual, Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: Operation Manual, Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket B, Horizontal Mounting, Option 3: Operation Manual, Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, ZSE20, "VACUUM SWITCH

Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None)

Socket/Plug: L (Semi-standard Socket), Thread Port Size: N01 (NPT 1/8), Barb Fitting Port Size: Not Applicable, Nut Fitting Port Size: Not Applicable, One-touch Fitting Port Size: Not Applicable, Connection Type: MS (Male Thread w/Sealant)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)