(mm) 2(A) Port size R(PT) 2(A) Port size R(PT) 1(P) 1(P) 1(P) 4 6 8 10 12 M5 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) M5 M5 4 M5 4 Tube O.D. (mm) Tube O.D.
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. (1500) 400 W L Load W ML2B32 ML2B32 W (1200) 300 ML2B25 ML2B25 L L 200 100 0 1000 2000 Support spacing L (mm) 718 ML2B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) Operating Range (mm) Auto switch
For IZTC41-L (controller), IZTP41-L and IZTP42-L are applicable. IZTP41-L and IZTP42-L can be mixed. Transistor input/output type and IO-Link type cannot be mixed. Table2.
44 53 99 53 66 86 22 40 81.5 1/4, 3/8 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 VCB31 30 50 86 1/2 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101 71 68 104 22 45 90 1/4, 3/8 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 VCB41 30 50 94 1/2 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 35 60 102 3/4 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 17-2-27
Body size 10 20 30 40 50 60 AV Thread type AU Metric thread (M5) Rc NPT G Nil AF N F AL20 Port size AR Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 (2) IR M5 01 02 03 04 06 10 Accessory When more than one specification is required, indicate in alphanumeric order. Note 2) For M5 and NPT thread types.
(mm) 3.2, 4 8, 10 6 4 3.2, 4, 6 12 38 7 Air flow (l/min(ANR)) Controlled flow JIS Symbol Effective area (mm2) 0.2 0.6 0.1 230 180 460 260 390 100 Air flow (l/min(ANR)) Free flow Effective area (mm2) 3.5 2.7 7 4 6 1.5 Note) Supply pressure: 0.5MPa Temperature: 20 OC How to Oder Indication of air flow direction on body AS 2 2 1 1 F M M5 06 S Meter-out Meter-in Body size 1 2 M5 1/8, 1/4 Options
Q 27 30 32 32 VCA21 VCA31 41 50 60 68 18 24 30 35 64 76 86 91 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5 M5 1/4 1/4, 3/8 3/8, 1/2 3/4 VCA41 17-2-13 8 Series VCA How to Order Manifold (VCA20) How to Order Manifold Assembly VV2C A 2 02 02 Enter the mounting valve and option part numbers under the manifold base part number.
4 Port Solenoid Valve Direct Operated Poppet Type Series VQD1000 How to Order Valves 5 1 5 L 1 VQD1 Type of actuation Made to Order Fluid-contact part: Oil-free X16 (A) 4 (B) 2 Single type Port size 1 M5 Nil M5 M5 thread Without sub-plate (Manifold) M5 thread Body ported 1 (P) 3 (R) Base mounted (A) 4 (B) 2 Latching type Electrical entry 2 L: Plug lead type L plug connector, With lead wire
The result is approximately 10 L/min (ANR). Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.
min] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Input/Output Characteristics: Flow Rate (Representative Value) Inlet pressure: 44 psi (0.3 MPa) Fluid: Water LVR20 LVR40 LVR50 12 [45] 26 [100] 1.1 [4] 24 [90] 11 [40] 0.9 [3.5] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Flow rate gal/min [L/min] 21 [80] 9.2 [35] 0.8 [3] 18 [70] 7.9 [30] 0.7 [2.5] 16 [60] 6.6 [25] 13 [50] 0.5
L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.
8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 2 M5 M5 AMR 1 4 2 1 (5) (5) Weight (kg) 0.15 0.18 0.2 0.3 0.5 1.4 2 4 ITV Note 1) No condensation.
supply L Model A 1.5 mm P.T. 20 N F.O.F. 7.5 VM122-M5-00 VM132-M5-00 37.5 VA 1.5 mm O.T. 3.5 VM123-M5-00 VM133-M5-00 2-4.6 mounting hole 33.5 3.0 mm T.T.
CE2 ML2B ML1C Mounting Position (Stroke End)/Reed Switch Mounting Position (Stroke End)/Solid State Switch D-E73A (L), D-E76A (L), D-E80A (L) D-M5B (L), D-M5N (L), D-M5P (L) D-M5BW (L), D-M5NW (L), D-M5PW (L) D-M5NTL, D-M5PTL REA REC RHC MTS CC Lead wire clamp/Lead wire cap (option) Series Lead wire clamp Lead wire cap ML1C LC-01 LP-01 Unit: mm Lead wire clamp/Lead wire cap (option) 25 32
Digital Flow Switch Unit Specifications Detection type Heat type Measured flow range 50 to 500 L/min 5 to 100 L/min Minimum unit setting 5 L/min 1 L/min Accumulated pulse flow rate exchange value (Pulse width: 50 [ms]) 5 L/pulse 1 L/pulse Accumulated flow range 0 to 9 L 5% F.S. or less (15 to 35C: Based on 25C) Linearity 2% F.S. or less Repeatability 5% F.S. or less (15 to 35C: Based on 25C
Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.
Holding: 0.6 W VX Power consumption (Current value) DC voltage (without power-saving circuit) 2.9 W VX3 AC 2 VA Electrical entry Grommet, DIN terminal VXA Note 1) Use dry air to prevent condensation when operating at low temperatures.
mm Holding point L mm Holding point L mm Holding point L mm Note) Distance to the holding point L of single acting type is shorten by spring return.
L/A indicator Table 10-22 L/A indicator L/A 1/2 Meaning Green ON Connection via Ethernet to the SI Unit via Port 1/2 (XF1/2) Green OFF No connection established via Port 1/2 (XF1/2) Yellow ON Transmission or reception of Ethernet telegrams on Port 1/2 (XF1/2) Yellow OFF No transmission or reception of Ethernet telegrams on Port 1/2 (XF1/2) Orange Flash Received Node flash request : When
VVQ2000-F-L Electrical wiring specifications [-K] C3 C4 C6 M5 VVQC1000-19AD S C6 (SUP port) D-sub connector Terminal no. 6 One-touch fitting SOL.