Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Model: H (Male Connector, Straight Union), Applicable Tube O.D. x I.D.: 0906 (5/16" x 0.236"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D. x I.D.: 0122 (1/8" x 0.086"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D. x I.D.: 0906 (5/16" x 0.236"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: H (Male Connector, Straight Union), Applicable Tube O.D. x I.D.: 0325 (5/32" x 0.098"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: H (Male Connector, Straight Union), Applicable Tube O.D. x I.D.: 0122 (1/8" x 0.086"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D. x I.D.: 0325 (5/32" x 0.098"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: T (Male Branch Tee, Union Tee), Applicable Tube O.D. x I.D.: 0122 (1/8" x 0.086"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: H (Male Connector, Straight Union), Applicable Tube O.D. x I.D.: 0704 (1/4" x 5/32"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D. x I.D.: 0704 (1/4" x 5/32"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: T (Male Branch Tee, Union Tee), Applicable Tube O.D. x I.D.: 0325 (5/32" x 0.098"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
Model: T (Male Branch Tee, Union Tee), Applicable Tube O.D. x I.D.: 0704 (1/4" x 5/32"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)