Cylinder port Symbol Port size Symbol Port size C3 C4 C6 M5 CM Note 1) L3 L4 L6 L5 B3 B4 B6 B5 LM Note 1) With 3.2 One-touch fitting With 4 One-touch fitting With 6 One-touch fitting M5 thread Mixed sizes and with port plug Top ported elbow M5 thread Bottom ported elbow with 3.2 One-touch fitting Bottom ported elbow with 4 One-touch fitting Bottom ported elbow with 6 One-touch fitting Bottom

The D-B5/B6/A3lA/A44A/G39A/K39A cannot be mounted on the bore size 20 and 25 cylinder with an air cushion. Note 1) Adjust the auto switch after confirming the operating condition in the actual setting. Note 2) The D-A3lA/A44A/G39A/K39A cannot be mounted on the centralized piping type CDM2lP series.

D-B5 D-B64 D-G5NTL 2015 + 50 ( n 2) (n = 2, 4, 6) 2 75 15 10 75 + 55 (n 2) Data 20 + 50 ( n 2) (n = 2, 4, 6) D-B59W 2 20 75 15 10-15-33 Series CVM3 Built-in One-touch Fitting CVM3 Mounting style Bore size For How to Order, refer to page 10-15-31. F Built-in One-touch fitting Specifications One-touch fittings are installed on cylinders.

CM Note 1) L3 L4 L6 L8 L5 B3 B4 B6 B8 B5 Metric size Inch size Note 10) G1, G2, or G3 cannot be combined with N.

Composite tube only) S T Y L E Standard Cylinder W Double Rod (Please see Page 19 for Mounting Information) K Non-rotating Piston Rod (5 to 14) O P T I O N S A Special Rod Thread (See Page 22) B5 Oversized Rod (See Char t below) B6 High Temperature * C3 Por t and Cushion Location (see Page 23) C6 Stainless Steel Piston Rod (Std. on XTSS series) C8 Adjustable Stroke Extended Piston Rod *

Standard Stroke Bore size (mm) Standard stroke (mm) Range of manufacturable stroke Auto switch model 40 CV Bore size (mm) 50 63 80 100 Without rod boot With rod boot Without rod boot With rod boot D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL 40 25 to 850 25 to 700 Up to 1200 Up to 950 MVGQ 50 25 to 800 25

Symbol 2 to 8 10 to 16 40, 50 20 to 32 U C D B Flat Flat with ribs Deep Bellows B4 M4 x 0.7 Symbol Applicable cylinder model Female thread M5 x 0.8 B5 M6 x 1 B6 M8 x 1.25 B8 D R D R X11 ZC(D)UK 10 Application: Refer to Table (1). Nil ZC(D)UK 16/32 M10 x 1.25 B10 Note) -X11 Pad: 2 to 8 diameter and flat style only available.

The ZPT series vacuum cups are available in diameters from 2 to 125mm, 6-cup materials, and 4-cup designs (flat, flat with ribs, deep and bellows), to suit multiple applications. Vertical vacuum entry connections can be made via one-touch fittings or threaded connections. Optional buffers can be ordered with up to 50mm stroke.  SMC's ZP2 series vacuum pads are available in diameters from

Contact Protection Box: CD-P11, CD-P12 Auto Switch Hysteresis D-A7/A8, D-A7H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C80C, DE7A, E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type The auto switches above do not have a built-in contact protection circuit.

Symbol: A0 Symbol: A1 Symbol: A2 Symbol: A3 DA C0.5 C 30 30 H H W1 T H A H Symbol: A4 Symbol: A5 Symbol: A6 Symbol: A7 RD B RD AL MM AL MM 30 H L 30 30 30 H L W H H Symbol: A8 Symbol: A9 Symbol: A10 Symbol: A11 C0.5 file chamfer AL B MM Made to Order Auto Switch WA C R sphere TP R sphere DC 30 H W1 T H H H Symbol: A12 Symbol: A13 Symbol: A14 Symbol: A15 R sphere C0.5 DA DA AL MM DA C

Symbol: A4 Symbol: A3 Symbol: A2 Symbol: A5 30 30 30 C0.5 30 Symbol: A7 Symbol: A9 Symbol: A6 Symbol: A8 Symbol: A10 approx.

Reed switch: D-A7/A8, Series MRQ Linear motion part size Solid state switch: D-F7/J7 Output of rotating part (at 0.5MPa) Linear motion stroke (mm) Rotation angle 5 10 15 20 25 30 40 50 75 100 80 to 100 170 to 190 32 1.02N/m An air cushion is also available. 80 to 100 170 to 190 40 1.91N/m Application examples A connecting port can be selected from two positions that are available on the rotation

Adapter Material: Brass, Standard, Vacuum Inlet Direction: T (Vertical), Pad Diameter: ø32, Pad Styles: C (Flat w/Ribs), Material: GN (Conductive NBR), Vacuum Entry: A8 (Male Thread M8X1)

Technical data 1209 Series CY1L Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range (mm) Bore size Auto switch model D-A7/A8 D-F7/J7 10 15 20 25 32 40 6 6 6 6 6 6 6 6 3 3 4 3 3 3 3.5 D-F79F 4.5 4.5 4.5 4.5 4.5 4.5 4.5 Since this is a guideline including hysteresis, not meant to be guaranteed.

Standard type CP96S Double acting, Single rod XA0 to 30 CP96S-W Double acting, Double rod XA0 to 30 Symbol: A0 Symbol: A1 Symbol: A2 Symbol: A3 Symbol: A4 C DA C0.5 30 RD 30 30 A H H H W1 H L T H Symbol: A8 Symbol: A9 Symbol: A5 Symbol: A6 Symbol: A7 WA C C0.5 file chamfer AL B RD B AL MM AL MM MM DC 30 30 H 30 30 L W H W1 T H H H Symbol: A10 Symbol: A11 Symbol: A12 Symbol: A13 Symbol:

D-A7, A8, A7lH, A80H, A73C, A80C, 9, 9lA, A9, A9lV, A79W The above switches do not have built-in contact protection circuits. q Operating load is an induction load. w Wiring to the load is 5m or longer. e Load voltage is 100, 200VAC. z Use a contact protection box in any of the above listed situations. The contact point life may decrease.

D-A8 type switches are used for 1oOVAC or less: since there is no voltage limitalion, you can select a suitable modeltoryoua needs.

Solid state swilch Reed switch L'-F/r3rypel_D_A7rvD D-J79 type J How to connect solid state switch Contact protective bo)dCD-Pl1,CD'PI2 Reed switch The auto switches of D-A7 A8 type, D-A7 EH.ASoH type, D-A7S.A80Ctvpe' D-C7 Cg type are not incorporated with contact protective circuit. 1 Operating load in an inductive load. 2 The wiring length to load is 5m or more. 3 The load voltages are

Not 2) tjse turbine oil No. 10so vG32), ff lubricated o @ Series NVFR4000: Base Mounted llpe How to Order Electrical entry O-Plug-in 64 tr;r, * X EA, EAj .a8 NPIF Bollom ported: 3/8 only (See pg. 40 for part no. ol individual subplates) NVFR4(2)O , With indicator light and isurge voll,age suppressor oP non-rotatina DIN connector t P, ZF-. onitDift type.

Metric size (Release bushing: White color) 03.2, 04, 06, a8, o1O, o12 . Inch size (Release bushing: Orange color) a1l8' , a5132" , 03116" , a114" , 05116" , a318" ,6112" Elbow TlpeflnJine lype Minimizes installation time and cost Fittings and tubing are not necessa4, because this type screws directly into the actuator. Thus, piping labor and cost can be eliminated.