Operating pressure (MPa) Bore size (mm) Piston area (mm2) Operating direction Rod size (mm) 0.7 0.5 0.3 12 16 20 25 CQSY12-PS Piston seal 1 pc. Rod seal 1 pc. Tube gasket 1 pc. Grease pack (10 g) 1 pc.
1 4.5 4.5 4.5 4.5 1 1 4.5 4.5 4.5 4.5 1 1 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 Hysteresis MHF2-8D D-F9(V) D-F9W(V) MHF2-8D1 Red ON Green ON MHF2-8D 0.5 0.5 1 MHF2-8D2 MHF2-12D 0.5 0.5 1 MHF2-16D 0.5 0.5 1 MHF2-12D MHF2-20D 0.5 0.5 1 MHF2-12D1 Auto Switch Mounting MHF2-12D2 Insert the auto switch into the switch mounting groove in the air chuck in the direction shown below, and after setting
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing August, 1998 D-SMC.L.A. P-69.5 (JT)
n = 1 + 2 + 3 1 Load factor n 1 = m/mmax Item Note Review m mmax is the maximum load mass 1. Max. load mass 2 = M/Mmax Review M1, M2, M3 Mmax is the allowable moment 2. Static moment 3 = Me/Memax Review Me1, Me3 Memax is the allowable moment 3.
I.D. 1 2 3 1 2 3 1 L 210 280 265 D 18 TCU0425B-1 TCU0425B-2 TCU0425B-3 TCU0604B-1 TCU0604B-2 TCU0604B-3 TCU0805B-1 52 35 22 54 27 17 41 1.5 4 2.5 28 1 2 1.5 1 2 24 325 6 4 37 305 330 8 31 5 Burst Pressure Characteristics Chart 725 Burst pressure psi 580 Burst pressure 435 290 145 Max. operating pressure 0 4 32 68 Operating temperature F 104 140 TUB-10 Polyurethane Coil Tubing (Metric) continued
P = 26 25 55.2 19 G: 300 H: 600 50.6 Applicable cable O.D. 6 to 8 Grommet (G, H) Pg9 DIN terminal (D, DZ) Manual override (Non-locking) For 4 x M4 (For mounting) 83 111 4.6 43.5 39.3 21.6 27 R R P 29 38 20 11 (1) 1 (Pitch) P = 26 1/8" [3(R) port] 1/4" [1(P) port] 28.5 12 18.5 L1 L2 6 (Station n) (Station 1) Max. 10 75.6 62.5 40 A A 31 1/4", 1/8" [2(A) port] (Pitch) P = 26 5 22 n: Stations
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing May, 2000 D-SMC.L.A. P-80 (YG)
CRJB 1-90 54 CRJB 1-100 1 CRJB 1-180 67 CRJB 1-190 CRJU05-90 47 05 CRJU05-180 53 With external stopper CRJU 1-90 70 1 CRJU 1-180 81 Note) Above values do not include auto switch weights. 2 Mini-Rotary Actuator Series CRJ Rotating Direction and Rotation Angle The shaft turns clockwise when the A port is pressurized, and counterclockwise when the B port is pressurized.
(between lead wire and case) 1000 VAC for 1 min.
(Symbol 1) IN (Symbol 2) OUT Option Nil None Bracket Manual override Bracket, Manual override 1 2 3 10R2 N.O.
(Example) SS3YJ3-20-03 . 1 set (manifold base) SYJ312-5LZ-M3 . 2 sets (valve) SYJ300-10-1A . 1 set (blanking plate assembly) SS3YJ3-42R-03-C4 . 1 set (manifold base) SYJ314R-5G . 2 sets (valve) SYJ300-10-2A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2017 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing VP printing VP 10680SZ Printed in Japan. D-G
Tel :03-3502-2740 Fax:03-5251-7240 August 1996, 14(RP)
Suction Verification High Vacuum Suction Work 1 Work 2 Work n Max. A P-1 H-1 n-1 Formula for Obtaining the Set-Value Min.
Insulation resistance 50 M or more at 500 VDC (between lead wire and case) 1500 VAC for 1 min. Note 1) (between lead wire and case) 1000 VAC for 1 min.
M8 Connector Flat Ribbon Cable Manifold Manifold Internal Wiring For more than 10 stations, both poles of the common should be 1. To order connector cable only Cable length(L) Part no. 300mm V100-49-1-1 500mm V100-49-1-2 1000mm V100-49-1-3 2000mm V100-49-1-4 5000mm V100-49-1-7 Flat Ribbon Cable Manifold In the manifold valves, the wiring to the individual valves is wired.