/OTHER), .59524 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)Weight (g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS4000-021/41,67025.51,67025.540, 50, 6380, 100221
(g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS2000-021/43405.22503.820, 25, 32, 40115
g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS4000-021/41,67025.51,67025.540, 50, 6380, 100221
Weight (g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS3000-021/481012.381012.332, 40, 50, 63130
(mm)Weight (g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS5000-021/42,840442,8404440, 50, 6380, 100242
Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS3000-021/481012.381012.332, 40, 50, 63130
Flow Range: 51 (50~500 l/min), Thread: N (NPT Thread), Port Size: 04 (Port Size 1/2), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 51 (50~500 l/min), Thread: N (NPT Thread), Port Size: 04 (Port Size 1/2), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Size: 4 (40), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: CS (Conduit, w/Surge Voltage Suppressor)
Size: 4 (40), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: B (24 VAC), Electrical Entry: DS (DIN Terminal, w/Surge Voltage Suppressor)
Size: 4 (40), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: DS (DIN Terminal, w/Surge Voltage Suppressor)
Size: 4 (40), Body Material: S (Stainless Steel), Seal Material: N (NBR), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: CS (Conduit, w/Surge Voltage Suppressor)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None]
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None]
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: NZ (N + Z)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: C (N.C. Float Type Auto Drain), Attachment: SV (S + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: NZ (N + Z)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: DG (D + G), Attachment: S (Pressure Switch), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: NZ (N + Z)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: SV (S + V), Semi-Standard 1: Standard, Semi-Standard 2: NZ (N + Z)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: M (Round Type Pressure Gauge w/Color Zone), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: NZ (N + Z)
Size: 32 (Body Ported), Operation: 2 (Internal Pilot Solenoid Valve), Port Size: 04 (1/2), Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 600mm), Surge Suppressor: None, Option: N (Silencer)