[F80] Power saving mode completed In power saving mode, when buttons are pressed the display is normal, but if no buttons are pressed for 30 seconds, it will revert to power saving mode.
Function selection mode 30 Default setting 30 F 0 Display units, switch output specifications and diagnostic information selection function 32 F 1 Setting of OUT1 34 F 2 Setting of OUT2 37 F 3 Digital filter setting 39 F 4 Auto-preset function 40 F 6 Fine adjustment of display value 42 F10 Sub display setting 43 F11 Display resolution setting 49 F14 Zero cut-off setting 50 F80 Power saving
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
Input signal: The external input line must be connected to GND for a minimum of 30 msec. When the input signal is ON, the screen will display [ooo] for 1 second. After turning OFF the input signal, flow accumulation resumes (displays peak value and bottom value) within 30 msec.
MXQ16B 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 33 23 23 23 29 38 63 63 63 MXQ20B 32.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 30.9 31.9 31.9 31.9 44.9 44.9 46.9 69.9 69.9 D-M9V/M9WV A 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6(A) 18 7.4 7.4 7.4 7.4 2 2.6 5.6 7.6 7.6 MXQ8(A,C) 13.9 13.9 13.9 13.9 13.9 13.9 7.1 7.1 7.1 13.1 30.1 7.1 MXQ12(A,C) 16.5 16.5 16.5 16.5
5F () Sub Function 9.5.1 1 F0 (P.30) 2 F0 Address 9.5.1 (P.30) 3 F0 Address(0) 0 4 F0 DATA(H) 9.5.1 (P.30) 5 F0 DATA(L) 6 F0 7 F0 815 F0 H= L= 46 - 11
C 10 20 30 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-6 Cooling capacity *The Radiating water flow rate of 1L/min is for reference. Radiating water Temp.20 Ambient Temp.20 Fluid water 1000 Cooling capacity W 5 Radiating water flow rate L/min 800 1 3 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp.
16.5 16.5 16.5 16.5 16.5 16.5 24.1 18.1 18.1 25.1 25.1 31.1 50.1 50.1 MXQ16B 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 33 23 23 23 29 38 63 63 63 MXQ20B 32.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 30.9 31.9 31.9 31.9 44.9 44.9 46.9 69.9 69.9 Solid state auto switch: D-M9M9 A Stroke Stroke Model 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6(A) 18 7.4 7.4 7.4 7.4 2
VXK2l3l 4.5 10 15 20 30 40 50 60 3 2 VXK 4l 6 30 60 3 2 VXK 50 8 25 30 Flow rate Q kg/h ( ): Saturated steam holding heat (kcal/kg) ( ): Saturation temperature (C) How to read the graph The sonic range pressure to generate a flow rate of 15 kg/h is P1 0.15 MPa for 4.5 orifice (VXK2l3lS), P1 0.37 MPa for 3 orifice (VXK2l2lS), and P1 0.82 MPa for 2 orifice (VXK211lS).
93 109 5 6 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 61.5 74 4.2-40 VND 32A, 40A, 50A Port size Model Main port Rc(PT) Pilot port Rc(PT) A B C D E F G H J 1 8 1 4 1 4 105 120 140 77 96 113 53 60 74 26.5 30 37 121.5 138 161 20 24 24 130.5 148 171 8 10 12 55 63 74 1 4 1 2 1 1 2 VND50D-32A VND60D-40A VND70D-50A Flange/32F, 40F, 50F Port size VX VN VQ Model Pilot port Rc(PT) Applicable
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
Page 30 [F 0] Units selection function -48No.PS-OMU0003-D
[F80] Power saving mode Power saving mode can be selected. When selected and no buttons are pressed for 30 seconds, the pressure switch will shift to power saving mode.
43.7 37.2 15 14 26 18 13.6 PFMB7202 90 35 49.2 42.7 17.5 24 31 28 16.8 S T U V W PFMB7501/7102 24 22 32 40 50 PFMB7202 30 30 42 48 58 -67No.PF-OMP0001CN-F (ZS-33-D) (ZS-33-F) -68No.PF-OMP0001CN-F Revision history A B C D E F [September 2016] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications
Do not use a cable longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply.
Bonnet assembly/construction part number:1 Valve size Temperature specifications 25 40 50 63 80 Caution General use XLD25-30-1 XLD40-30-1 XLD50-30-1 XLD63-30-1 XLD80-30-1 High temperature XLD25-30-1H XLD40-30-1H XLD50-30-1H XLD63-30-1H XLD80-30-1H Note1) The magnet for auto switch is not provided. When the magnet for auto switch is necessary, add -M9// at the suffix of the part number.
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Initial value Recommended Value Parameter *1,*2 Para No Number of command input pulses per revolution *3. PA05 100 100 Electronic gear numerator *3. PA06 1 100 (Positioning mode: 10) Electronic gear denominator *3.
Slider type LEKFS series 2.1 Specification AC servo motorMotor typeS*/T*) Model LEKFS25 LEKFS32 LEKFS40 Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000
Make sure to allow intervals of 15 ms or longer (30 ms is recommended) between input signals, and maintain the input state for the same period of time. 30 No.JXC-OMY0002-A -Output terminalNo. Function Description B1 OUT0 When the operation is started and DRIVE is turned OFF, a Bit no. corresponding to the number of the active step data will be output from these terminals.
Ion balance OK LED Within +/-30 V Lighting (or Flash) Outside of +/-30 V Goes off * OK LED Flashes when the offset voltage is near the adjusting target to notify the emitter maintenance timing is coming soon. ALARM LED: Indicates the abnormal states of the ionizer. Model Nu File 00 LED name Function HV Indicate that abnormal current flows to the emitter.
5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 32 1-1/4" 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a cylinder tube.