Series LQ3 High Purity Fluororesin Fitting Grip seal construction with 3-point seal Easy to assemble & construct Greater swept flow characteristics Excellent heat resistance 150C operating temperature How to Order LQ3 H M 1A Threaded connection Thread Type Symbol Nil N Type R, Rc NPT Fitting Style Symbol H L Style Straight Elbow Piping Type Symbol M Type Male Class Size Combination
: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient and fluid temperature: -10 to 50
Type 10, 11, and 12 connector connecting base manifold gasket part number: SY□ 0M-9-1A (10 pcs./set)
Valve part numbers: SY3100/SY5100/SY7100, SY3130/SY5130/SY7130, etc.
Type 50, 51, and 52 metal base manifold gasket part number: SY□ 0M-11-1A (10 pcs./set)
Valve part numbers: SY3100/SY5100/SY7100, SY3130/SY5130/SY7130, etc.
: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient and fluid temperature: -10 to 50
: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient and fluid temperature: -10 to 50
Spacer Type: SUP Stop Valve Spacer, Individual SUP/EXH Spacer Assembly: Straight, Port Size: -
Spacer Type: SUP Stop Valve Spacer, Individual SUP/EXH Spacer Assembly: Straight, Port Size: -
Spacer Type: SUP Stop Valve Spacer, Individual SUP/EXH Spacer Assembly: Straight, Port Size: -
(mm ) . 100 125 150 I 50 75 100 125 150 75 ~ 50 I 75 50 100 125 150 107 40 70 B3 83 97 11 5 128 128 194 52 62 204 212 225 225 1 83 107 50 70 83 ! 97 115 128 I 128 52 62 204 19' 212 2.?
Direct acting guide Series LXF 0.03 Ball screw 3 100 50 Series LXP 6 Ball bushing guide 100 Ball screw 0.03 50 5 100 Series LXS 50 10 High rigidity direct acting guide 100 Ball screw 0.03 50 5 100 5 Simplified Selection Flow Chart Series LX Standard stroke (mm) and 25 50 75 100 125 150 175 200 Model Motor Manufacturer Maximum speed (mm/s) Phases LXFH5SB LXFH5BC LXFH5BD LXFH5SA
Parameters will be loaded. 50 - 5.8 Saving/Loading Project 5.8.1 Saving Project From the Project menu in the setup software, select Save As. Please specify location to be saved. Please enter any project name. Click Save. Project will be saved in the specified folder.
No. w q Description ADC12 ADC12 e Note) Description Cap Body Motor Cam SCS13 r t C3604B 20137-1A Valve assembly y NBR S-16 O-ring 14-20-50 Note) Motor port no. in the case of 100 VAC: 812PG-100VAC
JSXFAH6-10m1-Bm JSXFAH6-10m2-Bm JSXFAH6-10m3-Bm JSXFAH6-10m4-Bm Outlet pipe dimensions A 68 108 68 108 B 173 5 213 5 173 5 213 5 Thread type G1" x 50 G1" x 90 Pipe thread (Pipe for the OUT port) 68 68 50 108 108 90 1" (ANSI) G1" G1" 1" (ANSI) 9 Pulse Valve Valve for Dust Collector JSXFA Series Dimensions: JSXFAH/Immersion Type Dimensions on the tank side A A 69 +1 0 0.3 A 0.4 ANSI 6" 168.3
How to Order 03 ADM200 1 Thread type Operating time/Applicable compressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Port size Voltage OUT IN Symbol 04 03 100 VAC Hz 1 3 8 3 8 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC
IDF15E1-10 (AC100V ) AC100V () IDF15E1-20 (AC200V ) L N PE M3 6.5mm 1.25mm 2 1 2 2. 2.1 ( ) 2 2 1 2. 2.2 2.2.1 (1) (85%) 240050 () 2000m (2) 2 2 2. 2.2.2 P.6-2 6.2 1 1 5 4 3 2 1 600mm 600mm 600mm 600mm 600mm 2 3 2. 2.2.3 50 50 (IN) (OUT) (IN) (OUT) (IN) (OUT) IN OUT 2.2.4 10mm ( ) 2 4 2. 2.2.5 6-1 IEC () IDF15E1-10(100V ) AC100V () [30mA 10A] IDF15E1-20(200V
Example for Installation How to Order ADM200 Port size OUT IN Symbol 04 03 3 8 3 8 1 2 3 8 Voltage Constructions/Dimensions 100VAC Hz 1 50 60 200VAC Hz 50 60 240VAC Hz 50 60 110VAC Hz 50 60 220VAC Hz 50 60 24VDC 12VDC 2 3 4 5 6 7 Operating time/Applicable compressor 2 sec./min. (1 cycle/min.) /3.7 to 37kW 4 sec./min. (2 cycle/min.) /37 to 75kW 6 sec.
/N.O. 1/4 to 1 10 to 12 10, 15, 20, 25 Fluid / Orifice Diameter Applicable fluid Orifice diameter [mm] Series Air Air Medium vacuum Medium vacuum Oil Oil Water Water Steam Steam 1 5 10 20 50 Hightemperature oil Hightemperature oil Heated water Heated water Can be used with heated water Can be used with heated water VX Series1 Direct Operated Pilot Operated 10 2 1 Single Unit VDW Series
voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV40001/21.5 MPa0.2 to 1 MPa1/80 to 60C (1)61760.74100, 200, 110 to 120, 220 VAC (50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV50003/41.5 MPa0.2 to 1 MPa1/80 to 60C (1)1131321.60100, 200, 110 to 120, 220 VAC (50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?