A93 A90 12 V 5 V,12 V IC circuit 100 V Relay, PLC 2-wire No 100 V or less 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
(g) Bag/Box Quantity D1 L1 5/32 1/4 1/4 3/8 3/8 1/2 1/2 1/4-18 1/8-27 1/4-18 1/4-18 3/8-18 3/8-18 1/2-14 KV2E03-35 KV2E07-34 KV2E07-35 KV2E11-35 KV2E11-36 KV2E13-36 KV2E13-37 1/2-20 9/16-18 9/16-18 7/8-14 7/8-14 1-12 1-12 17.46 17.46 17.46 25.40 25.40 28.57 28.57 17.46 17.46 17.46 25.40 25.40 28.57 28.57 31.0 27.5 32.4 34.5 36.9 37.1 41.2 14.7 9.8 14.7 12.1 14.5 13.7 17.8 16 17 17 21 21 22
Metric sizes Type 4 6 8 10 12 04 06 08 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 x 0.8 1/8 1/4 3/8 1/2 M5 01 02 03 04 With One-touch fitting Clean specification Metal part material Q G Brass (electoless nickel plated) Stainless steel (SUS304) Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06
depth 22 Up to 300 50 32 25 37 3 40 40 22 71 20 110 20 16 10 M26 x 1.5 M12 x 1.75 depth 22 Up to 300 60 41 30 37 3 40 50 26 (mm) Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 NA P S TA TB ZZ 11 11 77 1/8 24 114 Up to 200 11 11 77 1/8 29 119 Up to 300 11 11 79 1/8 35.5 121 Up to 300 12 12 87 1/8 44 139 Up to 300 13 13 102 1/4 55 162 Up to 300 13 13 102 1/4 69 162 Up to 300 122
Applicable model LVR20 LVR40 LVR50 03 3 x 2 LVR20 LVR40 LVR50 03 1/8" x 0.086" 04 4 x 3 05 3/16" x 1/8" 06 6 x 4 07 1/4" x 5/32" 10 10 x 8 11 3/8" x 1/4" 12 12 x 10 13 1/2" x 3/8" 19 19 x 16 19 3/4" x 5/8" LQ3 Metric size Inch size Symbol Applicable tubing size Applicable model Symbol Applicable tubing O.D.
Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.
Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.
drop 1 V or less Max. 80 mA Internal voltage drop 1.5 V or less SFD NPN open collector 1 output + Analog output PNP open collector 1 output + Analog output LLB LLB LLBF (F1) P2 P6 P1 P5 LLB-F (F1) AD Brown Brown DC (+) 1 1 Black OUT1 Load GD Main circuit Main circuit Black OUT1 4 4 12 to 24 VDC White Analog output White Analog output Load 12 to 24 VDC 2 2 Blue DC () Load Load Blue 3 3 P1
53.5 28 40 242 36.5 30 6.8 6.6 12 16 M6 x 1 M8 x 1.25 14 372 354 186 190 124 158 118 116.5 73 106 144 140 64 30.5 43 286 40.5 35 8.6 8.5 14 15 M8 x 1.25 M10 x 1.5 Model FF II NN AA BB CC DD EE GG JJ KK LL MM WW XX ML1C25 ML1C32 ML1C40 1/8 5 5 5 5 7 28 26 14 44 20 16 12.5 120 42 1/8 6 5 6 5 8 36 28 18 54 36 18 12.5 140 48 1/4 6 5 6 5 8 47 30.5 17 62 30 22 16.5 170 51 9-14-8 9 Series ML1C Mechanically
53.5 28 40 242 36.5 30 6.8 6.6 12 16 M6 x 1 M8 x 1.25 14 372 354 186 190 124 158 118 116.5 73 106 144 140 64 30.5 43 286 40.5 35 8.6 8.5 14 15 M8 x 1.25 M10 x 1.5 Model FF II NN AA BB CC DD EE GG JJ KK LL MM WW XX ML1C25 ML1C32 ML1C40 1/8 5 5 5 5 7 28 26 14 44 20 16 12.5 120 42 1/8 6 5 6 5 8 36 28 18 54 36 18 12.5 140 48 1/4 6 5 6 5 8 47 30.5 17 62 30 22 16.5 170 51 9-14-8 9 Series ML1C Mechanically
3 13 28 10.3 6 3 6 12 Conveyor lower limit position 1 R25 74 Stroke 2-M5 x 0.8 14 8 144 4 Front pressure port 12 Rear pressure port 70 4.5 2-Plug 12 18 40 (Width across corners 47) 36 Note 1) The figure shows dimensions at the maximum energy absorption capacity.
NPT 1/8 Nil Rc 1/8 TF G 1/8 Note 1) The figure shows dimensions at the maximum energy absorption capacity.
Valve model VCL2 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCL4 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 Mounting screws (for mounting bracket) are included
2 1 3/16 1 31/32 1 1/16 1 1/4 5/8 1 1 31/32 31/32 1 3/32 49 1/4 T4-90 1/4 T2 x 3 1/4 T4 x 3 1/4 T3 x 3 1/4 T1 x 3 1/4 T2 1/2 x 3 5/8 19/32 5/8 2 50 1/4 VT4 1/4 VT3 1/4 RVT4-2 Page 12 Distributed by Power Aire, Inc
. 10-1 10.3 CONNECTION OF POWER SUPPLY. 10-2 Chapter 11 Option T . 11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 OPERATION / ERROR SIGNAL OUTPUT . 11-1 11.3 REMOTE OPERATION . 11-2 11.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 11-3 11.5 ELECTRIC CIRCUIT . 11-4 Chapter 12 Option V . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 SPECIFICATIONS . 12-1 12.3 MAINTENANCE . 12-2 Chapter
Selection Graph Selection Graph 1. Tubing capacity Using selection graph (3) (P . 13-1-12) Tubing I.D. Piping Capacity, make a selection in the same manner as indicated in When no leakage occurs when picking up a workpiece. 2.
S GD I K L M Q R P 20 25 32 40 4 4 5.5 M6 X 1 3.5 60 25 26 54 M8 X 1.25 depth14 35 80 105 50 93 12 M5 X 0.8 MGP 7 7 9 4 70 32 31 62 40 95 60 12 M10 X 1.5 depth18 125 M8 X 1.25 103 M5 X 0.8 Rc(PT)1/8 Rc(PT)1/8 7 7 9 4 70 32 38 62 40 95 60 12 M10 X 1.5 depth18 125 M8 X 1.25 104 MGQ 8 8 11 4 38 47 67 45 75 12 150 M8 X 1.25 115 M12 X 1.75 depth 21 82.5 115 MGG Bore size (mm) WH U W Y T V Wq
Series ASV Speed Exhaust Controller Size: M3, M5, 1/8, 1/4, 3/8 . How to Order . Construction. Dimensions . Check Valve Series AK. Series AK Check Valve. Specifications. How to Order . Construction. Dimensions .