Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Deionized Water and Chemicals Series PF2D How to Order PF2D5 13 20 1 Remote type Sensor unit Output specifications Flow rate range Output for display unit Note 1) + analog output (1 to 5 V) Output for display unit Note 1) + analog output (4 to 20 mA) 3/8 1/2 3/4 1 2 11 13 19 Port size (inch) 0.4 to 4 l/min 1.8 to 20 l/min 4 to 40 l/min Note 1) Output for the display units of PF2D 300/301 04
In this case, pilot solenoid valve is VO307-DZ. 17-4-6 3 Series VNA Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Model Flow characteristics Measured by air Measured by water Note) Weight (kg) Orifice size (mm) Air operated Model Port size Rc Cv Av x 10-5 m2 b External pilot solenoid C [dm3/ (barsec) ] VNA1-6A VNA1-8A 1 8 1 4 10 0.88 1.5 1.9 3.8 4.8 7.5 25 41
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Drain cock Nil Metal bowl 2 ZL Thread type Port size Nylon bowl 6 Drain guide (Rc 1/4) 02 1/4 Nil J Rc ZY 03 3/8 F Flow: Right Left R G 04 1/2 N If ordering two options or more, indicate symbols numerically and alphabetically.
Operation t 0 Single Acting 03 10kgrf/crn'z 04 4kgt'lcm2 06 6kgrf/cnf 11 30psi 12 45 psi 13 150 psi 22 200 kPa 23 300 kPa 24 400kPa 26 600 kPa 41 30 psi & 2 k$l cm2 stainless steel t42 60psi& 4 k$lcm2 stainless steel 43 100 psi & 7 k$lcm2 stainless steel NIL PT Thread PF Parallel Pipe Thread t NPT American National Standard Pipe Thread Accessoriee t NIL Standard Lever Control Lengrth (0.25
Operation t 0 Single Acting 03 10kgrf/crn'z 04 4kgt'lcm2 06 6kgrf/cnf 11 30psi 12 45 psi 13 150 psi 22 200 kPa 23 300 kPa 24 400kPa 26 600 kPa 41 30 psi & 2 k$l cm2 stainless steel t42 60psi& 4 k$lcm2 stainless steel 43 100 psi & 7 k$lcm2 stainless steel NIL PT Thread PF Parallel Pipe Thread t NPT American National Standard Pipe Thread Accessoriee t NIL Standard Lever Control Lengrth (0.25
Switch with left hand mounting A t r t fit gI Switch with right hand mounting t[ n-r ffi I+l+| + t 2 switches With right hand moun0ng D-8G&2 D6A&1 Rotation Speed Range Model 20--{.03-0.3sec/90' Model 30-O.04-0.3sec/90" lf a rotation speed is used slower than 0. 3sec/90" sticking may occur. _n_ | d l l"l l l n , t d .
Laterial vacuum entry without buffer series, Pad diameter: 02, 04, 06, 08, 10, 13, 16, 20, 25, 32, 40, 50 (mm), Pad style: flat, flat w/ribs, deep, bellows, Material: NBR, silicon rubber, urethane rubber, flourine rubber, EPR, Rotating or non-rotating, Multiple vacuum entry/mounting thread diameters, Vacuum Pad, with Buffer, VACUUM PAD, ZP, ZP2, ZP3, M30, 41 lb
56 75 2.3 30 6.5 10.5 31 37 VXS24 1/2 28 70 37.5 94 35 14 22 48 35 14 M5 56 75 2.3 34 6.5 10.5 35 41 VXS25 3/4 33.5 71 38.5 105.5 40 17 24.5 62 33 15.2 M6 70.5 92 2.3 39 6.5 10.5 43 46 VXS26 1 42 95 49.5 111.5 40 20 24.5 66 37 17.2 M6 70.5 92 2.3 41 6.5 10.5 45 48 13.5 Electrical entry Grommet DIN terminal Conduit terminal Conduit Q R Q R S Q R S T Q R VXS23 1/4, 3/8 29.5 66 67 58 55 110.5
(EX245-EA2-1) No. 1 SI ON/OFF 2 3 4 SI 5 . 11 11 No.EX-OMU0020CN 2. . 2-1 EX245 DC24 V 1 msec IP65 CE RoHS AC500 V1 FE DC500 V10 M FE -1050 -2060 35%85%RH 1057 Hz0.75 mm p-p 57150 Hz49 m/s 2 XYZ 2 2 XYZ 3 () 147 m/s 12 No.EX-OMU0020CN 3. 3.1. 8 VQC4000 7 2 x M5 ( = 1.5 Nm) 2 x M5 (SI = 1.5 Nm) 4 x M* . 3-1 13 No.EX-OMU0020CN 3.1.1.
Bolts Size Tightening torque (Nm) M3 0.6310% M4 1.510% M5 310% 8.Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.
) (M5)X4 (b) DIN DIN DIN (M5X8) DIN 2 4 3.0[Nm] M5X8 DIN 1 2 2 3.0[Nm] DIN M5X14 A DIN B DIN DIN (M5X14) 0.40.6 [Nm] 0.40.6[Nm] 28 No.SFOD-OMT0009CN-B A B M5X14 (2) M3 29 No.SFOD-OMT0009CN-B (1) D (100) 2 (2) 2mm D : : (3) 40 50mm ()100mm , 100 30 No.SFOD-OMT0009CN-B 5. 5.1 (1) C PWR +24V 24-0V +24V (+) (+) (24-0V) (-) (-) JXC-C1 2) AWG20(0.5mm 1.76 +24V 24-0V (
No.PS-OML0002CN-G // ZSE30A(F) ISE30A 2 8 10 11 14 14 17 18 21 21 24 24 24 F0 26 F1 OUT1 27 F2 OUT2 30 F3 30 F4 31 F5 32 F6 34 F7 35 F8 36 37 F90 37 F97 39 F98 41 F99 43 44 47 48 49 56 56 58 -1No.PS-OML0002CN-G (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 7 Stations, A B Port Size: M5N (Base Mounted M5X0.8 NPT)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 12 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 2 Stations, A B Port Size: M5F (Base Mounted M5X0.8 G)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 2 Stations, A B Port Size: M5N (Base Mounted M5X0.8 NPT)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 2 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 3 Stations, A B Port Size: M5T (M5X0.8 NPTF)