Manifold Type Individual SUP Vacuum SERIES NZM VACUUM EJECTOR MANIFOLD D I M E N S I O N S NZM VA C U U M E J E C T O R M A N I F O L D 1 10 Stations Common supply and exhaust M a i n t e n a n c e a n d a d j u s t m e n t i s p o s s i b l e w i t h o u t d i s a s s e m b l y o f the manifold H O W T O O R D E R NZM V A C U U M E J E C T O R M A N I F O L D (N)ZZM B NUMBER OF STATIONS 01
Note 1) 01 1 station Note 2) The number of max. stations differs from kit to kit. (Refer to the table below.)
Piping diameter ZU05mA 0.5 90 48 7 13 14 3.9 18.6 ZU07mA 0.7 11 16 28 4.3 19.1 The piping diameter for each port should be the standard size of One-touch fitting.
Body size 10 20 30 40 50 60 AV Thread type AU Metric thread (M5) Rc NPT G Nil AF N F AL20 Port size AR Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 (2) IR M5 01 02 03 04 06 10 Accessory When more than one specification is required, indicate in alphanumeric order. Note 2) For M5 and NPT thread types.
In cases where back pressure effects actuator operation due to simultaneous operation of manifold valves, etc., this effect can be eliminated by installing a plate between the manifold block and the valve from which back pressure is to be prevented. 1 1 2 4 5 3 5 3 3-10-15 Series VQ7-6 Manifold Option Parts Silencer box VV71---SB Pilot EXH silencer AN110-01 This can be provided as a unit
. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/alarm No. 4. Requires set up software(MR Configurator2TM) . -11- 3.
Refer to "LECSC2-T Operation Manual (Simplified Edition)", section 5.7 for how to set the Point table. -28- Recommended Parameter Values [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Series Lead symbol H A B H A B T Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para. Initial value Recommended value No.
Recommended tightening torque (Nm) Thread size 1/4 3/8 1/2 Torque 12 to 14 22 to 24 28 to 30 -9- (2) Do not apply torsion or bending moment other than the weight of the product itself.
Example) ARP30K-03BE-1RY Symbol 20 30 40 Body size Description Nil K Without backflow function With backflow function With backflow function + Nil N F Rc NPT G Thread type + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) a Without mounting option With bracket With set nut (For panel mount) Mounting H + Note 1) Nil E G E1 Note 3) Without pressure gauge Square embedded type pressure
: 6 x 4 nylon tubing Name plate and caution plate for bowl in imperial units (PSI, F) Applicable model AL30 to 60 AL30 to 60 AL30 to 60 AL10 to 60 AL10 to 60 AL10 to 60 AL30 to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 Body size 10 20 30 40 50 60 Thread type Metric thread (M5) Rc NPT G Nil N F AL20 Port size Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 Note 2) M5 01
(Stacking base) Dimensions / Single unit (Base Mounted) 7 11 28 3 Specifications Poppet Valve construction Air, Inert gas Fluid Vacuum (1.33 x 102Pa) to max. operating press. (Refer to flow characteristics table below.)
Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
Operating Pressure: 01 [0.5 to 10 psig (0.0034 to 0.07 MPa)], Material: S (Body: Brass; Nozzle: 316 SS; Diaphragm: 316 SS), Ports: 4PL [4 Ports (1-In; 2-Out; 3-Gauge Port In, 4-Gauge Port In)], Connections, Inlet: 4 (NPT 1/4 Inch), Connections, Outlet: 4 (NPT 1/4 Inch), Gauge Port, Inlet 3: 4 [0 to 400 psig (0 to 3 MPa)], Gauge Port, Inlet 4: 40 [0 to 4000 psig (0 to 28 MPa)], Pressure Gauge
(SMC's inspection conditions) *2: The period of time from gate open state to clamp after signals comes to solenoid valve and from gate clam Conditions Pressure: 0.5MPa , Pipe length:1m, Gate Direction: Vertical Upper, Without Speed Controller, Solenoid Valve:SY5120-01 , Tube:TU0604 4 - 2.
A Mounting part (1) Fixed PD port 3 Guideline of PD port 1 PD port 2 tightening torque 3 to 5 [N-m] (5) Recommended One-touch fitting to be mounted at the PD port is the KQ2S06-01[]S or KQ2S07-34[]S. One-touch fitting may interfere with the top surface of the pad depending on the fitting dimensions.
q Body size 20 30 40 50 60 Symbol Description w Pipe thread type Nil Metric thread (M5) Rc N Note 1) NPT F Note 2) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + e Port size a Mounting Nil Without mounting option B Note 3) With bracket + Option r Nil Polycarbonate bowl 2 Metal bowl 6 Nylon bowl 8 Metal bowl with level gauge C With bowl guard Note 6) Note 6) Note 6) Note 6) b Bowl 6C
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
H2 A WH NN I MM H1 NE D LY ND NB 4-LD LH LT NF E 10 E JD N 10 JC N NA X Y X Y S+Stroke LX LZ LS+Stroke ZZ+Stroke (mm) Bore (mm) 20 25 32 40 Stroke range (mm) 200 to 700 200 to 700 200 to 1000 200 to 1000 I 26 31 38 47 F 16 16 19 21 A 18 22 22 24 E 14.5 18 18 20.5 D 10 12 12 16 GB 47.5 49.5 51.5 51.5 GA 53.5 56.5 55 56 Eff. thread length 15.5 19.5 19.5 21 JC 43 39 36 32 H1 5 6 6 8 LH 25 28
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]