Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.?
The series may be used as either a selector valve, or a divider valve. It is vacuum applicable up to –101.2kPa. Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal. It is possible to use the series in vacuum applications or under low pressure.
Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time.
Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time.
Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 1.00307 lb
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 0.97651 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 0.94106 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 0.89814 lb
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.?
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: J (Instantaneous Flow: L/min, Accumulated Flow: L, Temperature: °F), Bracket:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Temperature: °C), Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate)