With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Mounting: B (Basic Style), Bore Size: 63mm, Thread: TN (NPT), Stroke: 450mm, Stroke Adjustment: B (0 to 50), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC8 (Adjustable Stroke, Extension Type)
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 450mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 450mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
Mounting: Basic Style, Bore Size: 63mm, Thread: NPT, Stroke: 450mm, Stroke Adjustment: 0 to 50, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Adjustable Stroke, Extension Type
Magnet: Built-In, Mounting: Rear Trunnion, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 450mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option
Magnet: Built-In, Mounting: Front Trunnion, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 450mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option
Magnet: Built-In, Mounting: Rear Trunnion, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 450mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Option
Magnet: Built-In, Mounting: Front Trunnion, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 450mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Option
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 450mm, Motor: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector or
Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 450mm, Motor: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector or I/O Cable
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 32, Stroke(mm): 450, Max. Load Mass (Horizontal Mounting)(kg): 40~57, Table Size Length L(mm): 138, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Rolling Guide] Linear guide 2 axis, Table Size Width W(mm): 130, Table Size Height H(mm): 75, Table Surface Treatment: [Anodize] Alumite, Environment
SMCs horizontal type LEHF, 2-finger electric grippers are structured to maintain workpiece gripping force in the event of an emergency stop or restart. An encoder makes it possible to confirm positioning and to output length measurements. The LEHF series is available in standard or long stroke models.2-finger type, Body size: 10, 20, 32, 40, Manual override adjustment screw on both sides
SMCs LEHS, 3-finger electric gripper series, has been designed with a drop prevention function to maintain gripping force on workpieces during an emergency stop or restart. When a teaching box is used, the LEHS is easy to operate with just two parameters, position and thrust, to set *. The LEHS grips cylindrical and spherical, or easily deformed components easily.3-finger type, Possible
The LES series electric slide table actuator uses a compactly-integrated, recirculating linear guide for high rigidity and high precision. When the LES is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein.. Two types of built-in motors * are available. The series can be top or bottom mounted. In