Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Piping Specification: 01 (R 1/8), Connector Type: S (M12 connector type)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Piping Specification: 01 (R 1/8), Connector Type: S (M12 connector type)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Piping Specification: 01 (R 1/8), Connector Type: S (M12 connector type)

Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9N P P P p p IC circuit 3-wire (NPN) Solid state auto switch 5 V, 12 V 3-wire (PNP) M9P P P P p p 2-wire 12 V M9B P P P p p 3-wire (NPN) 5 V, 12 V M9NW P P P p p IC circuit 3-wire (PNP) M9PW P P

M N O P Q J K L M N O P Q Part no.

Cushion valve G 2 x Rc P W V Port G E Width across flats KA TX D E B C H1 AL MM MB MA N 2 x 4 x J N TY B C Width across flats B1 A H K F TT ZZ + Stroke S + Stroke With rod boot d e 10.2 10.2 f h l [mm] Bore size [mm] A AL B B1 C D E F G H H1 J K KA MA MB MM N P S TT TX TY V W ZZ 32 22 19.5 46 17 32.5 12 30 13 13 47 6 M6 x 1 6 10 16 4 M10 x 1.25 27 1/8 84 17 48 49 4 6.5 135 40 30 27 52 22

Cylinder With$ Locking Mechanism Rc(PT) 1/4 Unlocking port (unlocked when pressurized) GC BB BA Plug with breathing hole Width across flats KA 2-Rc(PT) P M GA GA MM CD hole H10 Shaft d9 BZ GB 4-J 90 D 59 30 W 14 AL CX 5 A K CT N N U 43 C L S + Stroke H BY B RR Z + Stroke ZZ + Stroke With rod boot 75 l 15 40 h + l Z1 + l + Stroke ZZ1 + l + Stroke (mm) Bore size (mm) Stroke range (mm) 125

Table 8.1-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70

0.8 (P, R1, R2 port) 17.5 14 28 L plug connector (L): SYJ3140-L-M5 M8 connector (W0): SYJ3140-W0-M5 M plug connector (M): SYJ3140-M-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 64.3 [66.5] 54.5 [56.7] 63.4 56 49.5 R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 28 28 28 14 14 14 5 5 5 28.5 28.5 28.5 35.6 35.6 35.6 Refer to the page

= 400 mm/s (20) L = 100 mm, V = 400 mm/s 100 100 63 63 50 50, 63 50, 63 50 10 10 40 40 Load mass m (kg) Load mass m (kg) 40 40 32 32 32 32 25 25 25 25 20 20 20 20 1 1 0.1 0.1 10 100 50 51 200 10 100 50 51 200 Stroke (mm) Stroke (mm) 508 Model Selection MGPW Series L L m m Horizontal Mounting Ball bushing MGPWL20 to 25, MGPWA20 to 25 (21) L = 50 mm, V = 200 mm/s or less (22) L = 100 mm, V

R2 R1 P R2 13 5 10 10 10 M5 x 0.8 (P, R1, R2 port) 17.5 14 28 L plug connector (L): SYJ3140-L-M5 M8 connector (WO): SYJ3140-WO-M5 M plug connector (M): SYJ3140-M-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 64.3 [66.5] 54.5 [56.7] 63.4 56 49.5 R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 28 28 28 14 14 14 5 5 5 28.5 28.5 28.5 35.6

In the case of liquid: P Q = 1.9 x 106Av (9) G Q : Flow rate [l/min] Av : Flow coefficient [m2] P : Pressure difference [MPa] G : Relative density [water = 1] In the case of saturated aqueous vapor: Q = 8.3 x 106Av P(P2 + 0.1) (10) Q : Flow rate [m3/s] Av : Flow coefficient [m2] P : Pressure difference [Pa] P1 : Relative density [MPa]: P = P1 P2 P2 : Relative density [MPa] Front matter 4

With auto switch: CDS1C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ~ = Width across flats KA With rod boot ~ = ~ = S + Stroke Z + Stroke ZZ + Stroke ZZ1 + l + Stroke Z1 + l + Stroke Type Bore size (mm) Stroke range B C P A CDH10 CX G J K MM N AL KA RR L CT D

center B A B A P R R P R 3 Position exhaust center 3 Position exhaust center B A B A Solenoid Specifications P R R Grommet(G)/(H), L type plug connector(L), M type plug connector(M) P R Electrical entry 3 Position pressure center 3 Position pressure center DC AC50/60Hz 24,12,6,5,3 100, 110 , 200, 220 10% rated voltage 0.5(With light:0.55) 0.9(With light:1.0) 1.0(With light:1.1) [1.1(With

Selecting Conditions/Table 1 Vertical Upward facing Downward facing Horizontal l = Eccentric distance l = Distance between the plate and load center of gravity m Mounting orientation m m l = Eccentric distance Maximum load speed V Graph (Slide bearing type) Graph (Ball bushing type) 50 to 200mm/s 201 to 400mm/s 50 to 200mm/s 201 to 400mm/s 50 to 200mm/s 201 to 400mm/s 1 , 2 3 , 4 1 3, 1 4

Selecting Conditions/Table 1 Vertical Upward facing Downward facing Horizontal l = Eccentric distance l = Distance between the plate and load center of gravity m Mounting orientation m m l = Eccentric distance Maximum load speed V Graph (Slide bearing type) Graph (Ball bushing type) 50 to 200mm/s 201 to 400mm/s 50 to 200mm/s 201 to 400mm/s 50 to 200mm/s 201 to 400mm/s 1 , 2 3 , 4 1 3, 1 4

Set the speed to be 1 mm/s or more for the pushing operation. 9.6 Step Data setup (P.50) 11.3 Pushing operation (P.55) Check that the parameter values are set correctly for a pushing operation in the Step Data. Confirm that TL signal is turned ON.