Note 1) Body size AS-F AS-F With indicator Metric size Inch size 2 1/8, 1/4 3 3/8 4 1/2 Type Tubing O.D. 23 3.2 Note 2) Tubing O.D. 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" TMH 2 Elbow 04 4 06 6 08 8 10 10 12 12 16 16 ASD Control type Note) AS 0 Meter-out 1 Meter-in Indicator window direction AS-FE Note) Meter-out and meter-in types can be visually identified by color of the knob
fitting for 4 C4 Port size 4(A), 2(B) port One-touch fitting for 6 C6 M5 x 0.8 VF One-touch fitting for 5/32" B3 One-touch fitting for 1/4" B7 Flow Characteristics VFR Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size 1(P), 5/3(R) port Manifold 2(B), 4(A) port C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VP4 VV5Z3-40 VV5Z3-41 VV5Z3-42-01 VV5Z3-42-C6 VV5Z3-43 0.16 0.17 0.21 0.20
LVC DIN terminal: D Conduit terminal: T Cable 6 to 12 LVA F S Q 27.5 34 F (Q) LVH LVD LVQ LQ R C U 25 LVN C (44) R E R TI/ TIL G1/2 E PA G1/2 A H D (S) B B A H D 2-P Port size 2-P Port size PAX 2-M Thread depth N 2-M Thread depth N PB L L K K N.C.
Option Nil M ZS-24-A ZS-24-B ZS-24-D ZS-35-C Fixed SI unit Note 2) Bracket A With 2 mounting screws of each M3 x 5L, M4 x 5L Bracket B With 2 mounting screws M4 x 5L With unit switching function Note 1) P (Initial value psi) Bracket D With 2 mounting screws of each M3 x 5L, M4 x 5L Panel mount adapter (Piping: For 01/N01) Panel mount adapter (Piping: For W1/WF1/M5/C4/C6) Panel mount adapter
Note 1) The same bracket is used for VCS3 and VCS4 (port size 1/2). 17-2-44 7 Series VCS Direct Operated 2 Port Solenoid Valve For Steam Dimensions Grommet:G Conduit: C Q 300 F D 280 D Q F VC C G1/2 C R R VDW VQ E E B A H 2-P Port size VX2 A B H 2-P 2-M Thread depth N 2-M Thread depth N VX Port size Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main
N.C N.C 2 position double (metal) 4 position dual 3 port valve (B) 24 VDC 5 4 2 A B Note) B 1 5 3 P EA EB N.O N.O C: Locking type (Manual) Note 1) Function 2 2 position double (rubber) 4 position dual 3 port valve (C) Standard type (1 W) High voltage type (1.0 MPa) Negative COM External pilot Low wattage type (0.5 W) Nil K N R Y D: Slide locking type (Manual) Note) A B 4 2 C Seal Note 2)
M5 1/8 3/8 1/2 3/4 1 10 20 30 40 50 60 B With bracket Thread Port size Rc(PT) NPT G(PF) N F 8 M5 X 0.8 1/8 1/4 3/8 1/2 3/4 1 M5 01 02 03 04 06 10 C R With bowl guard (Only AL2000) Flow direction: Right to left With drain cock and barb fitting (6, 4 for nylon) (AL3000 to AL6000) 3W AL3000 When specifying more than one option, please list alphabetically.
(Double) Port size C2, C4 (2, 4 one-touch fitting) Mass (g) 31 40 V110-C2/C4 Flow Characteristics Flow characteristics Port size 2a, 2b 1(P)2a/2b C [dm3/(sbar)] C [dm3/(sbar)] 2a/2b3(E) 1(P) b b C2 C4 0.03 0.03 0.22 0.19 0.05 0.05 0.31 0.29 C6 The effective area S (mm2) is approximately 5 times as large as the sonic conductance (S C x 5). 2 3 Port Solenoid Valve Series VV100 Construction
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WEN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (16 points) 2 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#B (8 points) 0 1 EX600-DY
HRW Series 5.3 Operation Screen 5-3 HRX-OM-K003 Chapter 5 System Operation 5.3.3 Status screen 2 1 2 3 4 Figure 5-5 Status Screen 2 Table 5-4 Status Screen 2 No.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
. 2-2 2-2-3 . 2-2 2-2-4 . 2-3 2-2-5 . 2-3 2-3 . 2-5 3 / 3-1 . 3-1 3-2 . 3-1 3-3 . 3-2 3-4 . 3-2 3-5 . 3-2 3-6 . 3-2 4 4-1 . 4-1 4-2 . 4-1 4-2-1 () . 4-1 1 4-2-2 . 4-1 4-2-3 . 4-2 5 5-1 . 5-1 6 6-1 . 6-1 6-2 GWP . 6-3 6-3 . 6-4 6-4 . 6-5 6-5 . 6-7 7 C 7-1 . 7-1 7-2 . 7-1 8 K 8-1 . 8-1 8-2 . 8-1 9 L 9-1 . 9-1 9-2 . 9-1 9-3 . 9-2 9-4 . 9-2 10 M 10-1
Standard stroke range (mm) Long stroke range (mm) Bore (mm) TC GB GA F E AL TB C D B1 ZZ A H H1 I J K KA MM NA P S TA WA WB W WH 30 12 12 12 13 14 14 20 20 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 14 11 11 20 25 32 40 50 63 80 100 8 10 12 16 20 20 25 30 18 22 22 30 35 35 40 40 15.5 13 17 17 19 27 27 32 41 10 (12) 35 5 6 6 8 11 11 13 16 26 31 38 47 58 72 89 M4 X 0.7 Depth 7 5 6 8 10 14 18 18
) (6) (7) D 7)VQ100 Ass yP.41 (2)Q2 (3)LO 8)(2)J1,J2Q2 P.8 (3)C 7 - No.ZQ-OM01401-B ZZQ108A-L O C-A (1) (2) (3) (4) (3) (PD) (1) B (: P ) 01 1 2 (: PD ) C 02 2 2) (10) S (4) : 08 8 (2) (PV) 1) 3 A L 3)Assy R 1) V PV PS 1 1) V V (2)PV (3)PD PS PV PD PS PV PD L B C R B C 8 - No.ZQ-OM01401-B 2. 2.1 () (PE) (2 ) (P) (V) (PS) (PV) V 9 - No.ZQ-OM01401-B
36 132 50 41 200 74 60 230 74 60 271 86 70 22 36 110 180 544 612 873 JIS Symbol 1 4 1 2 2 Construction/Parts/Dimensions ANA1-01 to 06 Sound absorbing Case material (PFV ) End plate Hexagonal flats ANA1-06: PP How to Order Cover ANA1-10 to 20 Sound absorbing material Body Tension bolt End plate A1 03 AN Port size Symbol Connection Port size 1 8 01 1 4 3 8 1 2 3 4 02 03 04 06 10 12 14 20 (
ZQ-OM01301-A Vacuum Pump System Manifold ZZQ108A-S O C-A (1) (2) (3) (4) (3) Vacuum release pressure supply port (PD port) (1) Number of stations B None (Release pressure is 01 1 stations supplied from the P port.) 02 2 stations C Note 2) Provided (Breaking pressure: Supplied : from D port) 08 8 stations Note 2) Select S for the Option Symbol (10). (4) Shipping condition (2) Vacuum pressure
L A B C Lead 20 10 5 2.86 20 10 5 Parameter *1,*2 Para.
Port size Body size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Metric size Inch size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Flow rate 0 5 10 Number of needle rotations Refer to the Web Catalog for details.
LEC-CG2b) M12 4pin b) M12 4pin 2. LEC-CGD 2. LEC-CGD 4.LEC-CGR c) M12 4pin c) M12 4pin 1. LEC-CG1b) M12 4pin b) M12 4pin a) RJ45 8P 1. LEC-CG11.
Symbol Applicable compressor output (guide) Thread type Symbol Nil Type 2C 4C 8C 11C 22C 2.2 kW 3.7 kW 7.5 kW 11 kW 22 kW Symbol Nil Description Page for details P.68 P.69 Rc G1 With differential pressure gauge (GD40-2-01) With IN-OUT flange With differential pressure gauge (GD40-2-01) and IN-OUT flange N.C., N.O. auto drain, drain piping type F N X6 X15 NPT 1 Conforms to ISO1179-1.